You are on page 1of 43

LOGO!

8 - Introduction

For internal use only / Siemens AG 2012. All Rights Reserved.

LOGO! 8 News

Roadmap LOGO! 8
LOGO! 8 Hardware, functions
LOGO! Soft Comfort V8 Improvements /
News
Exercises

For internal use only / Siemens AG 2012. All Rights Reserved.

Roadmap LOGO! 8 and LSC V8


Q1

03
2014

Q2

06
2014

HMI 2014
Light & Building
2014

08/2014

Q3

09
2014

Q4

12
2014

Q1

03
2015

Q2

06
2015

LOGO! 0BA8
all BM and EM
+ Micro SD-Card
+ TD based Web-Server
+ add. 4 outputs Q17 Q20
+ 8 AQ
+ 6 Lines, 3 background colors

LOGO! App V3

LOGO! TDE

+ for LOGO! 7 and 8


+ I/O Table
+ Upload Datalog file
+ access protection via PW

+ 2 Ethernet Ports
+ 6 Lines, 3 background colors

LOGO! Soft Comfort V8

available

+ Single-Program and Network Mode


+ automatic IP assignment
+ Web-Server
+ Data exchange via D&D

Under
development
planned

LOGO! CMR 2020

LOGO! 8 News

+ New design for all BM and EM


+ Complete BM family of 8 BM (like LOGO! 6)
+ All expansion modules (like today but not compatible with old EM/BM)
+ all LOGO! BM & EM in one release
+ New LOGO! TDE
+ Communication with: KNX, CSM, GSM (AS-I not planed yet)
+ New design for LOGO! Power

Seite 4

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8 Hardware

+ 4 TE housing like LOGO! 6


+ standard Micro SD-Card
+ captive cover (cant get lost)
+ new display
+ 6 lines (16/10 characters per line)
+ 3 background colors (white, amber, red)
+ additional functions
+ adjustable startup time
+ new menu structure
+ add. outputs Q17 .. Q20
+ add. Analog outputs AQ 3 ..8
+ Dataloging to MSD-card max. 20.000
records in one file

All LOGO! 8 BM and Nur


EMfr
in internen
one release
(except KNX/EIB)
Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt
Seite 5

6/13/15

Industry Sector

LOGO! 8 Hardware
New display:
+ 6 lines, 20/24 characters per line
+ 3 backlight colors (white, amber, red)
+ 2 Ethernet ports
+ 3 pin standard power connector
+ selection list for target LOGO! BM
+ Operator / Admin mode

Attention: When migrating a program you must add the IP address of the new LOGO! TD and the target
LOGO! IP-Adr.
Seite 6

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8 Hardware

LOGO! 8 TDE: Two LOGO! connected to


the two Ethernet port:
Selection to which LOGO! the TDE should
communicate and show the message texts

Seite 7

6/13/15

LOGO! 8 TDE: A LOGO!8 and a PC


connected to the two Ethernet port:
Communication of LOGO! Soft Comfort V8
and the TDE possible at the same time.

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 Installation

LOGO! Soft Comfort V8

Seite 8

6/13/15

Free update via LOGO! Internet page


or via Help / Update Center

Supports all actual operating systems


(Windows, Mac and Linux)

Available languages:
+ German
+ English
+ Italian
+ French
+ Spain
+ Chinese
other languages possible via DDK
translation in the regions

Supports all LOGO! version


(0BA0 .. LOGO!8)

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 Installation

Not when LSC V8 is released!


Installation of the pilot version of
LOGO! Soft Comfort V8:
Copy the complete folder to your local
hard disk. Open the folder of your
operating system (Win, Mac or Linux)
Windows: change to the right folder
based on your installation (64 or 32 Bit)
Execute the file:
LOGOComfort.exe

Seite 9

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8: Diagram Mode

1. Menu bar

2
3

2. Standard Toolbar (fix)

3. Program mode

4. Program Toolbar (fix)


5

5. Program Editor
6. Status bar
7. Diagrams
8. Function blocks

Seite 10

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8: Diagram Mode

2.

Standard Toolbar: separate icons for RUN/STOP

3.

Program mode:
Change from diagram to network mode

4.

Program toolbar

- selection
- connect
- cut/join connection
- comments
- align automatically
- align horizontal
- align vertical
- bring to front
- send back
- Undo
- Redo
- constants connectors
- basic functions
- special functions
- Data-Loging

Seite 11

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


- undo split
Industry Sector
- split into two windows

Connect to LOGO! in Diagram mode

Seite 12

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Connect to LOGO! Diagram mode

1.

Interface selection
(Ethernet, Com-Port, USB)

2.

Interface number
(if more then just one is available)

3.

Target IP-Address of LOGO! 8

4.

Scan for available devices

5.

List of available devices

6.

Check connection to target LOGO! (3)

6
3
4
5

Exercise: Connect to LOGO! using automatic IP


assignment with different IP-Addresses of LOGO!

Benefit: Automatically set/reset of the Ethernet interface


Seite 13

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Migration from older LOGO! Programs to LOGO! 8

Seite 14

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8: Migration from LOGO! x LOGO! 8

Migration from older LOGO!


Programs to LOGO! 8

1.

File/open

2.

Select file and press open

Exercise: Open an old LOGO! program and migrate


to LOGO! 8 including __Web-Server.

Seite 15

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8: Migration from LOGO! x LOGO! 8

Migration from older LOGO!


Programs to LOGO! 8
1. Change hardware to LOGO! 8
2

Seite 16

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8: Migration from LOGO! x LOGO! 8

Migration from older LOGO! Programs to LOGO! 8


1. Check properties of message texts
2. Select messages for Web-Server

3. Download program to LOGO! 8

Seite 17

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8: Migration from LOGO! x LOGO! 8

Migration from older LOGO! Programs to LOGO! 8


1. Open the file properties File/Properties
2. Enable Web-Server and specify a Password
for Web-Server login

Seite 18

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8: Migration from LOGO! x LOGO! 8

Migration from older LOGO! Programs


to LOGO! 8

Seite 19

6/13/15

1.

Add your LOGO! 8 IP-Address to


connect to the integrated Web-Server

2.

Select the view you need


+ LOGO! System
+ LOGO! Variables
+ LOGO! Base module
+ LOGO! TDE

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8 Migration from LOGO! x to LOGO! 8


Program it

Select it

Enable it

Open it

+ with all common PC Web-Browsers


(Internet Explorer, Chrome, FireFox, )

+ with all Smartphones (optimized resolution)


(Android, iOS, WindowsPhone, . with
common Internet browser (Opera, Chrome, .)
+ with all Tablet PCs (optimized resolution)
(Android, iOS, Windows, with common
Internet browser)
Seite 20

6/13/15

Supported operation:
+ Parameter changes
configured in a message text
+ Cursor buttons at LOGO!
BM or LOGO! TDE used in
the LOGO! Program
+ LOGO! TD function keys
used in
the LOGO! Program

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

New in LOGO! Soft Comfort V8

Seite 21

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Referencing


Exercise: Create a program for LOGO! 8 using an
analog amplifier as a reference for an Off-Delay.

Change HW between LOGO! 6/7 and LOGO! 8


1.

Referencing up to V7 via FB-Selection

2.

Additional icon for shown referencing


information
- Expand all parameter boxes
- Collapse all parameter boxes
- Show reference lines

3.

Reference in LOGO! Soft Comfort V8


- Parameter box of FB
- Reference done like wiring of signal

Benefit: Better documentation, diagnostic and


overview of referenced values

Seite 22

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Special flags

1
2

1.

Direct selection of special flags from the list

2.

Clear separation color of special flags

3.

Set color for special flag in


Tools/Options/Colors

Exercise: Change the color for the special flags.


Create a program including special flags
Exercise 2: create a program where a service
telephone number is shown on the displays with
flashing red background color.

Benefit: Simple to program and clear differentiation of special flags via different color

Seite 23

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Astronomical clock

New:
Additional delay time for sunrise
and sunset.

Exercise: Create a Program for


LOGO! 8 with some astronomical
clocks with different delays and
simulate it.

Benefit: Individual setting depending on the application (light control, animal breeding, ..)
Seite 24

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Weekly timer

Weekly timer:
All settings in one dialog

Exercise: Create a Program


including a weekly timer and
simulate it in LOGO! Soft Comfort

Benefit: Simpler to configure and better overview of the settings


Seite 25

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Access control settings

Access Control settings:


1.

Remote access for LOGO! Soft Comfort V8


LOGO! Soft Comfort (Telelservice)

2.

Access control for LOGO! App

3.

Access control for Web-Server

4.

LOGO! TDE Menu (Admin / Operator mode)

Benefit: Separate access control and PW for all remote connections


Seite 26

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : I/O Settings

I/O Settings:
Configuration for onboard analog
input at a LOGO! Base module:
+ Disabled (for 8 PT100/1000)
+ 2 AI (Default)
+ 4 AI (max.)

Benefit: Up to max. 8 temperature measures for all LOGO! 8 Base modules


Seite 27

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 : Function block position

LOGO! 8 and LOGO! Soft Comfort V8:


Same position of FB after program upload.
(Requires LOGO! Soft Comfort V8 and LOGO! 8)
Upload LOGO! 7

Upload LOGO! 8
Exercise:
Download and upload
some programs to
LOGO! 8

Benefit: Better diagnostic because of same FB position after upload


Seite 28

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8: V-Memory in LOGO! 8

New address range

V-Memory in LOGO! 8
New addresses. Customer using the LOGO! 7
addresses have to change ti

Date & Time address range

Date & Time information in LOGO! 8


New addresses range for date & time.
Read / Write supported
Exercise: Start simulation and add the addresses for
date & time into a data table.

Seite 29

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8: Datalog

New data logging with LOGO! 8

Max 20.000 records

A new datalog file will automatically generated


on the MicroSD-card

The last one can be uploaded by


LOGO! Soft Comfort V8

Record to internal memory same as LOGO! 7

Benefit: Long term recording with automatically created new datalog record.

Seite 30

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! TDE Admin / Operator mode

Seite 31

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! TDE : Admin / Operator mode

LOGO! TDE Admin / operator mode


With * marked points can not be selected
in Operator mode.

* Start
* Program
Setup
Network
Diagnostic
* Card

Most important limitations in operator mode:


- RUN / STOPP
- Program changes
- Program name
- Password changes
- All functions related to MSD-Card

Benefit: Password protection for accidentally changes


Seite 32

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! TDE : Admin / Operator mode


Exercise: Enable and configure the TDE
Operator/Admin mode and test it.
Access control setting:
1.

Remote access for LOGO! Soft Comfort

2.

Access fro LOGO! App V3

3.

Web-Server access

4.

LOGO! TDE Menu (Admin / Operator)

Benefit: Separate password protection for remote access and TDE


Seite 33

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Network mode

Seite 34

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8 Network Mode: Overview

4
9
5

6
7

10

Seite 35

6/13/15

1.

Menu bar

2.

Standard Toolbar

3.

Program mode

4.

Network Toolbar

5.

Network view

6.

Status bar

7.

Program editor

8.

Status bar

9.

Network project

10. Function blocks

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! Soft Comfort V8: Interfaces

1.

Connection via programing cable


- Select LOGO! Cable
- Port selection (COM-number / USB)
- Test connection

2.

- Ethernet-Interface selection
- IP of target LOGO!
- Search connected devices
- Address book
- Test connection to selected device
- List of connected devices

3.

Seite 36

Connection via Ethernet

Connection via Dyn-DNS (Internet)


- Select Dyn-DNS
- Dyn-DNS Name of LOGO! 8
- Test connection

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Exercise 1: Connect to LOGO! 8 in network mode


Exercise 2: Migration of old programs LOGO! 6 / 7 LOGO! 8
Exercise 3: Import of programs in network mode
Exercise 4: LOGO! communication in network mode

Seite 37

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Exercise 1: Connect to LOGO! 8 in network mode

Network mode
1

1. Press Go Online to automatically


detect connected LOGO! 8
2. View of connected LOGO! in network view
2

Benefit: Automatically configuration of IP setting to find connected LOGO! devices


Seite 38

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Exercise 1: Connect to LOGO! 8 in network mode

Network mode
1. LOGO! device on the network,
program part of the network project
2. LOGO! device on the network,
No program of this LOGO! part of the
network project
1

3. Manually added LOGO! Device to the


network project.

Benefit: Clear identification of devices.


Seite 39

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Exercise 3: Add programs to a network project

Add programs to a network project:


1. Via D&D from Diagram Network Modus
Only programs for LOGO7 or 8 can be added.
Programs for older LOGO! must change in
dialog mode first
2. Via direct Import

Seite 40

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Exercise 4: Data transfer with LOGO! 8

Configuration via Drag & Drop

Drag the signal (digital or


analogue) from one diagram to
another one

Clear view of network


information.

Simplest handling

Seite 41

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

LOGO! 8 Communication in network mode


1

1.

PC or PG

2.

LOGO! 8 with configured connection

3.

LOGO! 7 with configured connection

4.

S7 compatible device (S7-1200, 300, )

5.

Simatic HMI (Basic or Comfort


Panel)

6.

LOGO! TDE (view only)

7.

Shortcut:
Link to project file. To start other
programing tool like TIA-Portal from
LOGO! Soft Comfort V8

Seite 42

Different devices in network view:

6/13/15

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalt


Industry Sector

Thank you for your attention!

H. Schindler
I IA AS FA SB-PRM 3
Phone: +49 (0)911 / 895 - 3665
E-Mail: Helmut.schindler@siemens.com

For internal use only / Siemens AG 2012. All Rights Reserved.

You might also like