You are on page 1of 19

Illumination

Design of a Single
Family Residential
Unit
SENGCO, REGINA MAE M.
EE114D

Description of the Project


This design shows the lighting and switching layout of a a 200 sq.
meter single story residential house. It also includes the
illuminance level of each room and the design of the luminaries that
will be use on different parts of the house. It is also show the
computation of the calculux and zonal cavity method.

Illuminance levels selected for


each room/area

Living Area - 150 lux

Dining Area 150 lux

Kitchen 500 lux

Master Bedroom 150 lux

Bedroom 1 200 lux

Bathroom - 150 lux

Laundry 150 lux

Garage 150 lux

Selection and Description of


Luminaires
For Living Room: (Zonal Cavity Method)
Average maintained illuminance: 150 lux
Luminaire Data
Manufacturer: Cooper
with cover/ 35K

Lamp Data:
Type and Color: Duplex Fluorescent

Number per luminaire: 2 pcs


Catalog Number: WN-232A
3100 lumen per luminaire

Total lumens per luminaire:

Selection and Description of


Luminaires

Selection and Description of


Luminaires
For the Bedroom (Using Calculux)
Average Maintained Illuminance: 200 lux
Luminaire Data
Manufacturer: Philips
White (840)

Lamp Data:
Type and Color: Recessed Downlight / Cool

Number per luminaire: 1


Catalog Number: QL55W
3500 lumen per luminaire

Total lumens per luminaire:

Selection and Description of


Luminaires

Calculations of Zonal Cavity


(IES FORM)
Step1

Step2

CCR=5(0)(3.7+5.4)/(3.7)(5.4)
=0
RCR=5(1.8)(3.7+5.4)/(3.7)(5.4)
=4.1
FCR=5(0.9)(3.7+5.4)/(3.7)(5.4)
=2.0

SELECTION OF LIGHT LOSS


FACTOR
Non recoverable

Recoverable

Luminaire ambient temperature


= 0.80

Voltage to luminaire = 0.95

Ballast factor = 0.88

Luminaire surface depreciation =


1.00

Total LLF = 0.80 x 0.95 x 0.88 x 1.00


x 0.98 x 0.85 x 0.90 x 0.92

Room surface dirt depreciation =


0.98

Lamp lumen depreciation = 0.85

lamp burnout factor = 0.90

Luminaire dirt depreciation =


0.92

Total LLF = 0.46

Results of Zonal Cavity


Table for Effective Ceiling or Floor cavity reflectances for various combinations

Step 3: Effective Ceiling Cavity Reflectance


Pcc = 80%

Results of Zonal Cavity


Table for Effective Ceiling or Floor cavity reflectances for various
combinations

Step 4: Effective Floor Cavity Reflectance


Pfc = 18 %

Results of Zonal Cavity

Results of Zonal Cavity


Pcc

80%

Pfc 30 18 10
RCR:
4

50 X

4.1
5

x = 47
45

Z
44 Y

39

y = 41

z = CU = 46.4 % =
0.464

Calculations
Average Maintained Illuminance
No. of luminaire = (Illuminance x Area) /
(Lumens per luminaire x CU x LLF)
vv

= 150 lux (3.7m x 5.4m) /


(3580 lm per luminaire x 0.75 x 0.464 x2lamp per

luminaire)
= 1.2
= 2 luminaires

ILLUMINANCE

Illuminance = No. of luminaire x lumen per luminaire x CU x LLF x


lamp per luminaire / Area
= 2 x 3580 x 0.75 x 0.46 x 2/ 3.7 x 5.4
= 249.4
= 250 lux

Lighting and Switching Layout

Schedule of Luminaires
Symbo
l

Quantity

Catalog
Number

Descriptio
n

Number of
Lamps

Lamp

Lumen per
lamps

Wattage

30

QL55W

Recessed
Pinlight

KBS200

3500

55

WN-232A

Circular
Fluorescent
Lamp with
cover

F32T8

3580

17

UL 1598

Linear
Fluorescent
Lamp

F28T5

3500

28

CALCULUX
Results of Lighting Design
Software

Designing the Bedroom lighting


using Calculux

Dimensions: Width: 3.5 m length:


5.6m height: 2.7m

Reflectance: Ceiling = 80%, Walls =


50%, Floor = 20%

Required Illuminance level: 200 lux (


localized)

Luminaire specifications: PHILIPS


KBS200 1xQL55W/840

Lamp Type: Recessed Downlight


55W