DESIGN CALCULATIONS FOR CONDENSER


T1 = 45 oC

T2 = 45 oC

Condenser

t1= 25 oC

t2 = 40oC

Inlet temperature of the process stream T1 = 45 oC


Outlet temperature of the process stream T2 = 45 oC
Inlet temperature of the water t1
= 25 0C
Outlet temperature of the water t2
= 40 oC
Mass flow rate of the process stream m
= 8060 Kg/hr
Enthalpy of Vapors of Process Stream
= 1940 KJ/Kg
Removed 1

Heat Load:
Q = m (1)
Q = 4343 KW

Mass flow rate of cooling water

Q
m
C p t

Cp = 4.2 KJ / Kg.K

= 68.9 Kg/sec

Log Mean Temperature Difference


LMTD = (t2-t1)/ log (t2/t1)
LMTD = 14.4oC

Assumed Calculations
Assumed Value of Overall Coefficient UD = 1000 W/m 2C

True Mean Temperature Difference


Dimensionless Temperature Ratios
R
R = (T1-T2) / (t2-t1)
= (45-45) / (40-25)
= 0
S
S = (t2-t1) / (T1-t1)
= (40-25)/ (45-25)
= 0.75

From Literature the value of Ft is 1


tm

= Ft x LMTD
= 1 x 14.4
= 14.4 oC

Heat Transfer Area


A

Q
U D t

= 301 m 2
Surface Area of single tube = 3.14 x 19 x 4.88 / 1000
= 0.292 m 2
No. of tubes = 301/.292
= 1030
Pitch Pt
= 1.25 19.05= 23.8 mm

Tube Bundle Diameter

Db = d0 (Nt/K1)1/n1
= 19 (1030/0.158)1/2.263
= 920 mm

No. of tubes in centre row


Nr = Db / Pt
= 920 / 23.8
= 39

Shell Side Calculations


Estimate tube wall temperature Tw
Assume condensing coefficient of 4250 W/m2C (from literature)
Mean Temperature
Shell side =( 45+45) / 2 = 45 oC
Tube side = (25+40) / 2 = 32.5 oC
(45-Tw) x 4250
= (45-25) x 1000
Tw = 40.3 oC

Physical Properties
Viscosity of the liquid L
= 0.8 mNs/m2
Density of liquid L
= 993 Kg/m3
Thermal conductivity kL
= 0.571 W/m C
Average M. Wt. of Vapors = 42.8
Density of vapor = 29 x 273 x 1/(22.4 x 1 x (273+42))
= 1.12 Kg / m3
Condensate loading on a horizontal tube h = m / L x Nt
= 8060 / 3600 x (4.88 x 1030)
= 4.45 x 10-3 Kg/m s
# of tubes in the vertical row Nr = 2/3 x 39 = 26 mm
Heat transfer coefficient in condensation
h0 = 0.95 x kL ( L x (L v ) g / (L x h)1/3 x Nr-1/6
= 4396.0 W/m2C
As our assumed value is correct so no need to correct the
wall temperature

Tube Side Calculations


Tube cross sectional area
Density of water at 30 0C
Tube velocity

= 3.14 / 4 x (19 x 10-3)2 x 1030 / 4


= 0.073 m2
= 993 kg/m3
= m / (H2O x At )

= 68.9 / (993 x 0.073)


= 0.95m/s
Film heat transfer coefficient inside a tube
hi
= 4200(1.35+0.02 x t) Vt0.8 / di. 0 2
= 4809.67 W/m2 0C
From Literature take fouling factor as 6000 W/m2 0C
Thermal Conductivity of the tube wall material
Kw = 50 W/m0C

Overall Coefficient
1/U0 = 1/ho + 1/hod + (d0 ln(d0/di))/2kw +d0/di x 1/hid +d0/di x 1/hi
= 0.001
U0 = 1100.29 W/m2 0C
So assumed value is correct

Shell Side Pressure Drop


For pull through floating head with 45% cut baffles
From literature clearance
= 88 mm
Shell internal diameter Ds
= Db+88
= 1008 mm
Cross flow area As
= m2

A= 0.205 m2
Mass Velocity

Gt
= m / As
= 8060 / (3600 x 0.205)
= 10.92 Kg/s m2
Equivalent diameter de = 1.27 (Pt2 -0.785d02) / d0 = 19 mm
Viscosity of vapors
= 0.009 mNs/m2

Reynolds No.

Re = de Gt /
= 19 x 10-3 x 10.92 /0.009 x 10-3
Re = 23053

From literature

jf = 0.029
By neglecting the viscosity correction factor

Where

So

Ds = dia of shell
L = Length of tubes
lB = baffle spacing
= 765 N/m2
= 0.765 Kpa
= 0.109 Psi

Tube side pressure drop


Viscosity of water = 0.9 x 10-3 Ns/m2
Re
= Vt di /
= 0.95 x 993 x 16.56 x 10-3 / 0.6 x 10-3
= 26036
From literature
jf
= 0.0039

Where

Np = No. of tube passes

So
Pt
Acceptable

= 4119.8 N/m2
= 4.119Kpa
= 0.59 psi

hio = hi I.D/O.D
hio = 4165.2 W/m2 0C

Clean Overall Coefficient:


UC

h io h o
h io h o

= 2138.7 W/m2 0C

Design Overall Coefficient Calculated


Rd

UC UD
UCUD

dirt factor Rd = 0.0005

SPECIFICATION SHEET CONDENSER


Identification: Item condenser
No. Required = 8
Function: Condense vapors by removing the latent heat of vaporization
Operation: Continuous
Type: 1-4 Horizontal Condenser
Shell side condensation
Heat Duty = 4343 KW
Tube Side:
Fluid handled: Cold Water
Flow rate = 68.9 Kg/sec
Pressure = 14.7 psia
Temperature = 25 oC to 40 oC

Tubes: 0.75 in. Dia.


1030 tubes each 16 ft long
4 passes
23.8 mm triangular pitch
Pressure Drop = 0.59 psi

Shell Side:
Fluid handled = Steam
Flow rate = 8060 Kg/hr
Pressure = 10 KPa
Temperature = 45 oC to 45 oC

Shell: 39 in. dia. 1 passes


Baffles spacing = 3.5 in.
Pressure drop =0.109 psi

Utilities: Cold water


Ud assumed = 1000 W/m 2C
Rd = 0.0005

Ud calculated =1100.97 W/m 2C

References

Chemical Engineering Design


Volume 6 by Coulson &v Richardsons
Process Heat Transfer
by D.Q. Kern
Plant Design & Economics for Chemical Engineers
5th Edition by Max S. Peters, Klaus D. Timmerhaus,
Ronald E. West
Perrys Chemical Engineers Handbook
by Robert H. Perry, Don. W. Green

You might also like