You are on page 1of 368

Nestle Binh An

GROWTH
Aseptic system
Training
August 25th 28th, 2014

TM-TPVN/HT
7/23/16

Agenda: 4 days

Day 1: Milk & Aseptic technology


08:00 08:30: Introduction
08:30 09:30: Aseptic processing systems
09:30 10:00: Thermal treatment definitions
10:00 10:30: Break
10:30 11:00: Basic microbiology
11:00 12:00: Time-temperature combinations
12:00 13:00: Lunch
13:00 13:30: Time-temperature combinations
13:30 13:45: Milk properties
13:45 14:00: Type of milk
14:00 14:30: Alcohol stability
14:30 14:45 : UHT systems
14:45 15:00: Types of UHT
15:00 15:30: Break
15:30 15:45: Available TP portfolios
15:45 16:00: Selection guide
16:00 17:00: Processing parameters
TM-TPVN/HT
7/23/16

Agenda: 4 days

Day 2: UHT
08:00 08:30: UHT Operation
08:30 09:00: Technical data
09:00 09:30: Main components & functions
09:30 10:00: Break
10:00 10:30: Process steps
10:30 12:00: P&ID detailed tracing - Use colored P&ID
12:00 13:00: Lunch
13:00 13:15: Critical control points
13:15 13:30: Cleaning
13:30 14:00: Activation chart
14:00 14:45: Alarm handling
14:45 15:15: Break
15:15 15:30: Recording
15:30 17:00: Hands-on

TM-TPVN/HT
7/23/16

Agenda: 4 days

Day 3: UHT (cont.)


08:00 09:00: The operator manual
09:00 10:00: Basic instructions to use
10:00 10:30: Break
10:30 11:00: Maintenance UHT
11:00 12:00: The maintenance manual
12:00 13:00: Lunch
13:00 13:15: Knowing the preventive maintenance system
13:15 13:30: Basic instructions to use Spare parts catalogue
13:30 14:30: Trouble shooting
14:30 15:00: Break
15:00 16:00: Trouble shooting
16:00 17:00: Hands-on

TM-TPVN/HT
7/23/16

Agenda: 4 days

Day 4: Aseptic Tank


08:00 08:15: Aseptic tank systems
08:15 08:45: Operations, processing parameters
10:00 10:30: Break
10:30 10:45: Technical data
10:45 11:00: Main components & functions
11:00 11:30: Process steps
11:30 11:45: P&ID detailed tracing Use colored P&ID
11:45 12:00: Critical control points
12:00 13:00: Lunch
13:00 13:15: Cleaning
13:15 14:00: Trouble shooting & Alarm Handling
14:00 14:30: Break
14:30 15:00: Operation manual
15:00 15:15: Maintenance Aseptic Tank
15:15 15:30: Preventive maintenance system
15:30 15:45: Basic instructions to use Spare parts catalogue
15:45 16:15: Hands-on
16:30 17:00: Summary & Evaluation

TM-TPVN/HT
7/23/16

Day 1:
Milk & Aseptic technology

TM-TPVN/HT
7/23/16

Aseptic processing systems


Absolute sterility not possible

Bacteria

N
Logarithmic destruction
Time/temperature would be
too drastic
Not possible to prove
by random testing
Not possible to prove sterility
(prove absence)

t Time
PSD.TPD&B.TH.3.02, AA05

Aseptic processing systems

Sterilization of food requires that all living


microorganisms be inactivated, including the
pathogens.
Product remains fresh for months without
refrigeration and preservatives.
Product:
Low acid (food pH > 4.5, milk pH > 6.5)
High acid (food pH < 4.5, milk pH < 6.5)

Product

Temp(C)

Time

Low acid

135-140

A few seconds

High acid

90-95

15-30 seconds

TM-TPVN/HT
7/23/16

Aseptic processing systems


UHT - Ultra High Temperature

Vegetative cells

Yeast

Spores

Pathogenes

Mould

Virus

Aseptic processing systems


UHT - Ultra High Temperature

Vegetative
cells

Pathogenes

Spores
Yeast

Mould

Virus

Aseptic processing systems


Ultra High Temperature processes

TM-TPVN/HT
7/23/16

Machine Introduction General


Product lifetime

TM-TPVN/HT
7/23/16

Aseptic processing systems

TM-TPVN/HT
7/23/16

Aseptic processing systems

TM-TPVN/HT
7/23/16

Aseptic processing systems


Pre-processing

Deaeration
Separation
Standardization
Homogenization
Pasteurization

TM-TPVN/HT
7/23/16

Aseptic processing systems


Deaeration with Tetra Alrox

TM-TPVN/HT
7/23/16

Aseptic processing systems


Homogenization

TM-TPVN/HT
7/23/16

Aseptic processing systems


Homogenization of dairy products

TM-TPVN/HT
7/23/16

Thermal treatment definitions

TM-TPVN/HT
7/23/16

Thermal treatment definitions


Sterilization

A process applied to a product with the object of


destroying all micro-organisms (by heat treatment
exceeding 100C)

Sterile

Condition in which living cells are absent or killed.

Sterilizer

Equipment used for sterilization: autoclave, hydrostatic


sterilizer or aseptic processing plant

Commercially sterile product

Product which is free from micro-organisms that can


grow and contribute to its deterioration under the
intended storage conditions

Aseptic

Condition to prevent bacteriological contamination

Thermal treatment definitions


The commercially sterile product must

Keep without deterioration

Remain stable and good commercial


value during storage

Free from micro-organisms and toxins


harmful to the health of consumers

Absolute sterility not possible

Thermal destruction is logarithmic

Not possible to prove by


random testing

Thermal treatment definitions


D-Value
The express D65 = 1 min
means that the number of organisms is
reduced with 1 D when treated one minute
at a processing temperature of 65 C.
2 minutes exposure results in 2D
1D = 90% reduction = 1 LCR
2D = 99% reduction = 2 LCR
3D = 99,9% reduction = 3 LCR
4D = 99,99% reduction = 4 LCR
LCR: Logarithmic Reduction

Thermal treatment definitions


Sterilization Efficiency
The Sterilization Efficiency of a
process is the number of LCR that
it gives on the most resistant
microorganism.

Thermal treatment definitions


z-Value
Is the change in temperature in C required
to cause 10 fold change in D-value
z = (T1-T2)/(logD1-LogD2)
A certain micro-organism is
characterized by a z-value of 10 C

Thermal treatment definitions


Most heat resistant of spores
Bacteria

D90-value (hrs)

B. Stearothermophilus
B. Subtilis
B. Cereus

> 100

30

C. Botulinum, strains A

D121-value (sec)
300

60
3

C. Botulinum, strains B/E <0,02

12
1,4
< 0,05

Thermal treatment definitions


Typical killing data for some micro-organisms
Group of Orgsm

D-value (min)

Vegetative Bacteria
(heat sensitive)

65

Vegetative bacteria
(heat resistant)

10

65

Bateria spores

0,2

121

Yeast and Mould

65

Mould
3
(heat resistant ascospores)

90

Temp (C)

Thermal treatment definitions


Definition of F0-value
The F0 makes it possible to compare the effect
of different time/temperature combinations
t

= sterilization time (s)

T = sterilization temperature, (C)


z = the increase in temperature
necessary to obtain the same
effect in one tenth of the time
F0 = 1 when heated one minute at 121.1C
F0 3 to achieve a commercially sterile product

Thermal treatment definitions


Definition of C*-value
C*-value is an indicator of chemical
changes in the product associated
with heat treatment
C* = 1
= heat treatment at 135C for 30.5 s.
and z = 31.4C
= 3% destruction of thiamine

Thermal treatment definitions


Lactulose value

Indirect measurement of chemical changes

Lactulose is a type of milk sugar formed at


elevated temperatures and indicates the
extent of chemical changes to the product
e.g. the heat load

Lactulose is the way of measuring the


heat load on UHT milk, and also has
the advantage that its formation is
possible to calculate theoretically,
given the time-temperature curve

UHT treatment

Finding the optimal combination


of temperature and time
Sterilization effect
Chemical changes

Break

TM-TPVN/HT
7/23/16

Basic microbiology

Bacteria

Yeasts

Moulds

Basic microbiology
Multiplication of bacteria

1024
10 000 000
bacteria bacteria

30 min.
Generation time

30 min

11,5
hours

Basic microbiology

Temperature
conditions for

Maximum
Optimum

bacterial
growth

Minimum

Basic microbiology

Classification
of bacteria
by temperature
preference

Thermophilic

45 C

Mesophilic
20 C
Psychrophilic
7 C

Psychrotrophic

Basic microbiology
The influence of Temperature
Bacterial development in raw milk
Mio Bact/ml

Hours

Time-temperature combinations

TM-TPVN/HT
7/23/16

Time-temperature
Lethal effect on bacteria

TM-TPVN/HT
7/23/16

Time-temperature
Destruction of enzymes and micro-organisms

TM-TPVN/HT
7/23/16

Time-temperature
Combinations needed for destruction of spores

Lunch

Milk properties
Analyse of milk
The common tests carried out
on milk supplies are:

taste and smell


cleaning
sediment
somatic cell count
bacteria count
protein content
fat content
freezing point

Milk properties
Composition of Cow's Milk
Fat 4.1%
Protein 3.4%
Lactose 4.8% MSNF
Salt 0.7%

Water 87%

Total solid
=
Dry matter

Milk properties
Size of Cow's Milk Constituents

Whey Proteins

Bacteria

Lactose

Casein

Fat

Salts

0,0001

0,001

0,01

0,1

1,0

10,0

Particle size
100,0

Milk properties
Structure of milk

Fat globule

Skim milk

Milk properties
Raw milk quality

for processability:
pH
alcohol stability

6.65-6.80
>75%

for sterility level:


limit of heat resistant spores

Milk properties
Comparison of processability of Buffalo milk and Cows milk

Quality

Cows milk

Buffalo milk

Fat content (%)

3,2 - 4,8

6-7

Protein content (%)

3,2 - 3,4

4,3 - 4,5

Casein content (%)

2,6 - 2,8

3,51 - 4,36

Whey proteins (%)

0,6 - 0,8

0,53

75

142,2

6,65 - 6,80

6,9

80

72

Colloidal Ca (mg/100ml)
pH
Alcohol stability (%)

Milk properties
Quality parameters for raw material UHT products
Improvement of
hygienic
conditions in raw
material
production
Total Count
Flavour
Adulteration
Somatic Cell Count
Etc.

Factors pertaining to
the suitability of
production
Spore Count
Protein Stability
pH
Dirt particles
Thermoresistant
enzymes
Etc.

Types of milk

UHT systems

UHT systems
Full range of solutions
Direct heating

Injection
Infusion

Indirect heating

PHE
THE

UHT systems Selection guide


Objective advice!

Premium
quality

4 UHT technologies
Tetra Pak masters
them all
Your demands
decide!

DIRECT
DIRECT
UHT UHT Product
properties
injection
infusion UHT
INDIRECT
INDIRECT
UHT
PHE
THE
Outstanding
efficiency

Types of UHT
Direct or indirect?

Direct UHT
Steam injection or steam infusion
Almost instantaneous heating & cooling
Low impact on quality
Higher operating cost

160C
Direct

Indirect

140C
120C
100C

Indirect UHT

80C

Tubular or plate heat exchanger


Somewhat slower heating and cooling
Somewhat higher impact on quality
Lower operating cost

60C
40C
20C
Pasteurization

20

40

60

80

100

120

SEC

Available TP Portfolios

Indirect systems

Tetra Therm Aseptic Flex

Direct systems

Tetra Therm Aseptic VTIS

Available TP Portfolios
Aseptic tank system

Tetra Alsafe LA

Available TP Portfolios
Aseptic dosing

Tetra Aldose

Aseptic dosing

Tetra FlexDos

Available TP Portfolios
Tetra Therm Aseptic Flex

Cost-effective

Efficient operation by indirect


heating in tubular heat exchanger
Applications from white milk to
high viscous ice cream mix
Capacities from 2,000 - 40,000l/h

Available TP Portfolios
TA Flex Simplified flowchart

Available TP Portfolios
Tetra Therm Aseptic Flex

Tetra Spiraflo

Tubular heat exchanger (THE)


Floating ends for thermal expansion

Available TP Portfolios
Tetra Therm Aseptic Flex

Tetra Alex homogenizers

Improved efficiency
with counter-pressure
Efficient break-up of
clusters
Minimal number of
spare parts

Available TP Portfolios
Tetra Therm Aseptic VTIS

Premium product quality

Direct heating by steam injection or


steam infusion
Applications from white milk to high
viscous ice cream mix
Capacities from 2,000 - 30,000l/h

Available TP Portfolios
TA VTIS
Simplified flowchart

Available TP Portfolios
Tetra Therm Aseptic VTIS

Direct steam injection

Instant heating, temperature equilibrium and condensation


Very low fouling outstanding cleanability
Unique verified performance

Available TP Portfolios
Tetra Therm Aseptic VTIS

Steam infusion

Patented air
insulation design
reduces fouling
Patented, even
steam distribution

Available TP Portfolios
Tetra Therm Aseptic VTIS

Flash cooling

High-precision temp. control

Large product surface gives


instant cooling

Low carry-over

Unique, built-in condenser


gives short pre-sterilization
and cleaning times

Extremely low hold-up


volume

Easy access for inspection,


service and maintenance

Processing principles

UHT milk manufacturing process

Pre-sterilization

Production

(Aseptic Intermediate CIP AIC)

CIP

Day 2:
UHT

TM-TPVN/HT
7/23/16

UHT Operation

Tetra Therm Aseptic Flex - NG CM


Ser. No.: T5844151227
Indirect UHT
Continuous aseptic processing module
Using Tubular Heat Exchanger (THE)
Product: Milo

TM-TPVN/HT
7/23/16

Technical data

Tetra Therm Aseptic Flex - NG CM


Ser. No.: T5844151227
Indirect UHT
Continuous aseptic processing module
Using Tubular Heat Exchanger (THE)
Product: Milo

TM-TPVN/HT
7/23/16

Technical data

Noise Emission
Product configuration
Connection data
Specification, heat exchanger

TM-TPVN/HT
7/23/16

Main components and functions

Feed module
Booster module
THE
Homogenizer
Local control panels (FCP)
Motor panels (MCC)
Homogenizer panel (MCC)

TM-TPVN/HT
7/23/16

Main components and functions

TM-TPVN/HT
7/23/16

P&ID detailed tracing - Use colored P&ID


Main sides
Pre-heating

Holding cell
Aseptic side

Cooling

Balance Tank

Hot water side

TM-TPVN/HT
7/23/16

P&ID detailed tracing - Use colored P&ID


Measuring points

TC67

TC44

TSL42

PC78

PT05

TT08

PC74

PC68

TM-TPVN/HT
7/23/16

P&ID detailed tracing - Use colored P&ID


Hot water circuit

M10

TM-TPVN/HT
7/23/16

P&ID detailed tracing - Use colored P&ID


Hot water circuit

M9

TM-TPVN/HT
7/23/16

Machine Introduction Main steps

Sterilizing
Production
AIC
CIP

TM-TPVN/HT
7/23/16

Activations diagram
Sterile water Production AIC Shutdown EM Emptying

TM-TPVN/HT
7/23/16

Activations diagram
Full CIP

TM-TPVN/HT
7/23/16

Activations diagram
Adapted Cleaning

TM-TPVN/HT
7/23/16

Activations diagram
Header batch sub-program

TM-TPVN/HT
7/23/16

Machine steps
Process cycle: Phases and Steps
Step 1 17: Sterile water
Step 21 45: Production
Step 51 55: AIC
Step 70 71: Shutdown
Step 80 85: Emergency emptying
Step 101 149: CIP (Full cleaning)

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 1 - 17

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 1: Activate Valves

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 2: Activate Pumps

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 3: Fill up Plant

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 4: Active Steam

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 5: Heating

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 6: Sterilizing

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 7: Cooling 1

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 10: Cooling 2

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 11: Cooling 3

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 12: Stabilizing

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 17: Sterile Water

TM-TPVN/HT
7/23/16

Machine steps Sterile water


Step 17: Hibernation ( Be skipped if no time)

TM-TPVN/HT
7/23/16

Machine steps Production


Step 21 - 45

TM-TPVN/HT
7/23/16

Machine steps Production


Step 21: Prepare Production

TM-TPVN/HT
7/23/16

Machine steps Production


Step 24: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Production


Step 26: Fill BTD over Low Level

TM-TPVN/HT
7/23/16

Machine steps Production


Step 27: Fill Machine, Mix to Dest.

TM-TPVN/HT
7/23/16

Machine steps Production


Step 28: Fill Machine, Pure to Dest.

TM-TPVN/HT
7/23/16

Machine steps Production


Step 29: Production

TM-TPVN/HT
7/23/16

Machine steps Production


Step 40: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Production


Step 41: Fill. Mix in BTD

TM-TPVN/HT
7/23/16

Machine steps Production


Step 42: Empty BTD

TM-TPVN/HT
7/23/16

Machine steps Production


Step 43: Empty. Machine to Dest.

TM-TPVN/HT
7/23/16

Machine steps Production


Step 43: Empty. Machine to Dest.

TM-TPVN/HT
7/23/16

Machine steps Production


Step 44: Empty. Machine to Reclaim

TM-TPVN/HT
7/23/16

Machine steps Production


Step 45: Rinsing

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 51 - 55

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 51: Wait for Metering

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 52: Caustic Dosing

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 53: Caustic Circulation

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 54: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps AIC


Step 55: Rinsing

TM-TPVN/HT
7/23/16

Machine steps Shutdown


Step 70 - 71

TM-TPVN/HT
7/23/16

Machine steps Shutdown


Step 70: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Shutdown


Step 71: Rinsing

TM-TPVN/HT
7/23/16

Machine steps Emergency emptying


Step 80 - 85

TM-TPVN/HT
7/23/16

Machine steps Emergency emptying


Step 80: Act. Valves

TM-TPVN/HT
7/23/16

Machine steps Emergency emptying


Step 83: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Emergency emptying


Step 84: Empty. Machine to Reclaim

TM-TPVN/HT
7/23/16

Machine steps Emergency emptying


Step 85: Rinsing

TM-TPVN/HT
7/23/16

Machine steps CIP (Full cleaning)


Step 101 - 149

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 101: Activate Valves

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 102: Activate Pumps

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 103: Fill up Plant

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 104: Activate Steam

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 111: Rinsing + Metering

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 112: Wait for Metering

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 113: Caustic Dosing

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 114: Caustic Circulation

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 115: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 121: Rinsing + Metering

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 123: Wait for Metering

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 124: Acid Dosing

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 125: Acid Circulation

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 126: BTD Emptying

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 148: Rinsing LT

TM-TPVN/HT
7/23/16

Machine steps Full Cleaning


Step 149: Rinsing

TM-TPVN/HT
7/23/16

Critical control points (CCP)

TM-TPVN/HT
7/23/16

Critical control points (CCP)

Sterilization temperature TC44, TSL42:

Return line temperature TSL71

Sterilization Water Sterile Production AIC

Homogenizer pressure PT827, 827.2

Production

Product side flow-rate FC06, FC04

Sterilization Water Sterile Production AIC

Product holding tube pressure PSL05

Sterilization, CIP

Homo steam barrier temperature TSL30, TSL831

Sterilization Water Sterile Production AIC

Production

Product temperature at outlet TC26, TI06

Production

TM-TPVN/HT
7/23/16

Care and Cleaning

TM-TPVN/HT
7/23/16

Care and Cleaning


Verify Cleaning

Daily check
Check recorder to see if cleaning completed correctly
Lye/Acid concentration
Homogenizer dampers: Disassemble dampers to ensure an air
cushion inside and:
No product residues after cleaning
Manually cleaning if necessary
Balance tank CIP nozzles

TM-TPVN/HT
7/23/16

Care and Cleaning


Verify Cleaning

Recommended check

Regularly weekly/monthly verify the cleaning result at critical points


such as Holding cell.
Visual check for any product residues after cleaning.
Make a swab test to check to cleaning result.
If necessary, adjust the cleaning circulation time and detergent
concentration.

TM-TPVN/HT
7/23/16

Care and Cleaning


Cleaning CPP

Holding cell (HC)


Homogenizer dampers
V51

TM-TPVN/HT
7/23/16

Care and Cleaning


Recommended detergents & Concentration

TM-TPVN/HT
7/23/16

Care and Cleaning


External cleaning

TM-TPVN/HT
7/23/16

Alarms

TM-TPVN/HT
7/23/16

Alarms
Fault indication

When a fault occurs, the alarm lamp will start to


flash
Red lamp: Danger indication
o Flashing or continuous
Yellow: Fault indication
o Flashing light: unacknowledged alarm
o Continuous light: acknowledged alarm
Green: Normal operation
o Flashing: Attention required, function
o Continuous: Function in operation

ends

Always investigate the cause of fault indication. Otherwise you


may endanger the equipment or the product.

TM-TPVN/HT
7/23/16

Alarms
Alarm Handling

Divided into 2 categories: A, B and C alarms


A Faults that will cause an alarm only, they are not critical
but it will make the operator aware of an incident.
B Faults that will start corrective actions in the control
system. These actions are described in Alarm list.
C Faults that start interlock

TM-TPVN/HT
7/23/16

Alarms
Alarm list & Troubleshooting

TM-TPVN/HT
7/23/16

Alarms
Alarm list & Troubleshooting

TM-TPVN/HT
7/23/16

Recording
Logoscreen 500CF

TM-TPVN/HT
7/23/16

Day 3 - Operation Manual


Control panel

TM-TPVN/HT
7/23/16

Control Panel

TM-TPVN/HT
7/23/16

Operator Panel (TPOP, HMI)


General
HMI is link between TTA Flex PLC and operator

Operator -> PLC:


Enter necessary commands
Enter parameters (process & system parameters)

PLC -> Operator:

Retrieve system status information (steps, phase, alarms, )

TTA Flex PLC can also connect to overall control system


(SCADA)

TM-TPVN/HT
7/23/16

HMI
Access levels

TM-TPVN/HT
7/23/16

HMI Menu tree


Menu is available from any screen picture

Overview menu
Operating menu
Process values
Alarm list
Trend
Service menu

TM-TPVN/HT
7/23/16

TPOP Layout

TM-TPVN/HT
7/23/16

TPOP Layout

TM-TPVN/HT
7/23/16

TPOP Layout

TM-TPVN/HT
7/23/16

HMI Button and symbols

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

With 3D effect

Type of button:
Navigation
Function
Process
Dialog

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

Navigation button:
Call

up screen picture
Example: Home button call up Overview screen

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

Navigation button:
Call

up screen picture
Example: Home button call up Overview screen

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

Function button: Select machine function. Different


color code: different status. Ex:

1.
2.
3.
4.

Not selected and not selectable


Not selected and selectable
Connected but not selected, selectable
Selected but not correctly connected,
selectable
Connected but not selected, not
selectable (Remote control)
Selected but not correctly connected, not
selectable (Remote control)
Selected and correctly connected,
selectable
Selected and correctly connected, not
selectable

5.
6.
7.
8.

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

Process button: Select process sequences. Ex:


Push button positions
Not selectable

Selectable

Selectable and
pressed

Idle
Process phase not selected

Process
status

Queued
Process phase selected but not yet
active
Held
Process phase active but paused

Run
Process phase selected and active

TM-TPVN/HT
7/23/16

HMI Button and symbols


Button

Dialog button: Perform different operations, such


as validating, pause or cancelling any commands
Ex: Dialog buttons are used to Start, Pause, Abort and
Finalize a function

TM-TPVN/HT
7/23/16

HMI Button and symbols


Symbol

Local/Remote control
Select by key switch on control panel

TM-TPVN/HT
7/23/16

HMI Button and symbols


Symbol

Process value indicator


Indicate the measured values (temperature, pressure, )
Example:

Touch to change controller values: Controller parameters


(TC, LC, ) and quantity value limits (TSL, PSH, )

TM-TPVN/HT
7/23/16

HMI Button and symbols


Symbol

Data input: Indicated by data field showing the


current value.
Example:

Indication on Set Point Buttons

Active set point


(green)

Inactive set point


(grey)
TM-TPVN/HT
7/23/16

HMI Menu screen picture

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Overview menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Operating menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Operating menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Operating menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Operating menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Operating menu

Flush product (option)

CIP supply line


V15 to drain
V15 to reject
Disable hibernation
Fill aseptic damper (option)
TM-TPVN/HT
7/23/16

HMI Menu screen picture


Start condition window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Start check picture
General Start Conditions
1 All controllers in Auto
2 All EMERGENCY STOP released
3 No alarms: LL BTD, Air pressure, Homogenizer, Temperature fault
4 All toggle switches in Auto
5 Connection and selection match
6 Local/Remote selector in LOCAL
7 Steam selector ON
Pre-sterilization Start Condition
8 CIP memory
CIP/AIC Start Conditions
9 CIP HB ready
10 BTD cover closed (option)

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Process value window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Alarm list

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Alarm list

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Trend diagram

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pen and variables select picture

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Product and Capacity

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Service menu window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Service menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force main window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O menu Activations picture

Grey : not activated


Green: activated

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O menu

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O Motor faceplate window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O Motor faceplate window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O Valve faceplate window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Force I/O Valve faceplate window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Analog input force window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Analog input force window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Volume setup

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Recipe edit

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Recipe edit

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Recipe edit

TM-TPVN/HT
7/23/16

HMI Menu screen picture


PID controller window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


PID parameter window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


PID parameter window

TM-TPVN/HT
7/23/16

HMI Menu screen picture


CIP Concentration

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pressure homogenizer stage 1

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pressure homogenizer stage 2

TM-TPVN/HT
7/23/16

HMI Menu screen picture


TC44 parameters picture

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Temperature Guard TSL42

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Temperature Guard TSL71

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Differential pressure guard PSL61, PSL 64

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Differential pressure guard PSL61, PSL 64

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pressure guard PSL847

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pressure switch PS66

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Pressure switch high PSH60 (after M4)

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Flow and holding cell time guard

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Level switch LS08

TM-TPVN/HT
7/23/16

HMI Menu screen picture


TS Stepforward

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Event log

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Sterilization cycle report

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Sterilization cycle report 2/2

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Product cycle report

TM-TPVN/HT
7/23/16

HMI Menu screen picture


Product cycle report 2/2

TM-TPVN/HT
7/23/16

HMI Menu screen picture


PAC CIP setup

TM-TPVN/HT
7/23/16

Preparations Operation Shutdown

TM-TPVN/HT
7/23/16

Preparations
Check points
Before starting the plant, perform checking:
o Connecting points are correctly fitted
o Supply line of power, steam, water, air, SA,
o Steam switch, Remote/Local switch
o All Emergency Stop buttons are released
o Holding cell for correct connection
o Correct connections for Homogenizer,
o Upstream/ Downstream equipments

TM-TPVN/HT
7/23/16

Operation
Content

Start sterilizing
Start production
Stop production
Sterile water
Emergency stop
Cleaning (AIC, CIP)
Cleaning supply line
Emergency emptying

TM-TPVN/HT
7/23/16

Operation
Start Sterilization

Selection/setting prior to start


Do

not start when personnel is present in risk area

TM-TPVN/HT
7/23/16

Operation
Start Sterilization

Start conditions:
Check
Check

no alarms are active


conditions in interlocks menu

TM-TPVN/HT
7/23/16

Operation
Start Sterilization

Start sequence

Checks/Operation during sequence


Heating - Sterilizing Cooling Stabilizing
Water seal for motors, Homogeniger,
Watch out for any alarms

Sterile Water

Sequence completed
Continue

with desired sequence: Production, AIC, CIP, Stop

TM-TPVN/HT
7/23/16

Operation
Star Production sequence

Start sequence
Start Production sequence in Operation menu
Cooling down (TSL71), prepare production
Automatically empty BTD, run product supply pump
Product is filled into the plant
When plant is ready for production, signals are given

to the

destinations (AFMs, Alsafe)


Note: If a disturbance occurs during Production, the plant will
automatically proceed to Emptying and end up in Sterile
water.

TM-TPVN/HT
7/23/16

Operation
Start Production sequence

Checking during sequence


Regular

check on the process values (flow, temp., pressure,

..)

Recommended max time for production


During

production, deposit may build up on the heat


exchanger surfaces and in product holding cell.
Check the pressure drop over the heat exchanger. If it is too
big, production must be stopped and cleaning has to be
done.
Check the temperature different between the heating
medium (TE08) and the products (TE44).

TM-TPVN/HT
7/23/16

Operation
Stop Production sequence

Select following function to stop the Production


Sterile
AIC
CIP
STOP

Water: see Revert to Sterile Water

TM-TPVN/HT
7/23/16

Operation
Revert to Sterile Water

During any kind of disturbance in production


sequence, the plant can be reverted to Sterile
Water.

Max time for Sterile Water:


It

depends on the product temperature in supply pipe to the


balance tank. At temp. of 15 C the milk can stand about 6
hours before it is destroyed and the TA Flex unit has to be
cleaned and re-sterilized.

TM-TPVN/HT
7/23/16

Operation
Stop sequence (Shut down)

Can be ordered from all program steps


Start sequence:

The

BTD is empty and water rinse sequence is started. The


plant is cooling down and ended up in Parking position.

TM-TPVN/HT
7/23/16

Operation
Emergency Stop

Sequence

Push EMERGENCY STOP on the control panel to stop the plant


immediately. All pumps will stop and all valves will be deactivated.

Warning
The machine may contain hot liquid or cleaning solution,
handle with outmost care to avoid exposure.
Start after Emergency Stop
Release all Emergency Stop buttons
Reset on Homogenizer control panel and FCP
The plant must be emptied by means of Emergency
Emptying function

Note: CIP must be ordered if product has entered the plant

TM-TPVN/HT
7/23/16

Operation
Aseptic Intermediate Cleaning AIC

Sequence
AIC

can be ordered to extend the production period before


Full Cleaning (CIP) is required.
AIC takes about 40 minutes, the plant remains sterile in its
aseptic part.

Start Conditions
From Sterile Water or from
HB tank is ready
BTD cover closed (option)

Production

Start sequence
Select AIC lye/lye-acid mode
Press AIC - Start button

TM-TPVN/HT
7/23/16

Operation
Full Cleaning (CIP)

Sequence
Select CIP directly after finish production
The CIP takes about 120 minutes.

Start conditions
From
From
From

Parking position
Sterile Water
Production

Danger: Chemical hazard. Do not start CIP when theres


personnel in the risk area.

TM-TPVN/HT
7/23/16

Operation
Full Cleaning (CIP)

Start sequence
Select CIP lye, lye/acid or PAC mode
Press CIP - Start button
Function button is Indicated with white
When completed, CIP indication goes off

and the plant

stops.

TM-TPVN/HT
7/23/16

Operation
Full Cleaning (CIP)

Halt sequence
Press

CIP - Pause button

Restart sequence
Press

CIP - Restart button

TM-TPVN/HT
7/23/16

Operation
Emergency Emptying

Sequence
Use

function to

Flush out the plant


Emptying after Emergency Stop to cool down the equipment

Start conditions
From Parking position
All general conditions are

full-filled

Start sequence

TM-TPVN/HT
7/23/16

Operation
Cleaning of product inlet transfer line

Sequence
The cleaning is carried out by inlet transfer line system.
Cleaning solution will be directed through V15 & V12.
V15 will pulse to drain 10s every 5 minutes, V13 will lower-

seat lift 2s every 60s.

Condition:
The

Start sequence
V15

plant is in Parking position or not in Production steps.

& V12 activated

Sequence finished
TM-TPVN/HT
7/23/16

Shutdown
Plant shutdown sequence

Check points
Close air supply
Close steam supply
Close water supply
Switch OFF the main

switch in Control panel

TM-TPVN/HT
7/23/16

Maintenance UHT

TM-TPVN/HT
7/23/16

Maintenance UHT
Maintenance Manual

Heat exchanger
Pumps
Valves
Sensors and transmitters
Other process components

TM-TPVN/HT
7/23/16

Maintenance UHT
Preventive maintenance system

TM-TPVN/HT
7/23/16

Maintenance UHT
Preventive maintenance system

Preventive maintenance recommendations


specifies:
Activities (what to do)
Service interval (when to do)
Spare parts (what to change)

TM-TPVN/HT
7/23/16

Maintenance UHT
Spare parts

TM-TPVN/HT
7/23/16

Maintenance UHT
Components instructions

TM-TPVN/HT
7/23/16

Maintenance UHT
Troubleshooting

Mechanical system
Electrical system
Automation

TM-TPVN/HT
7/23/16

Maintenance UHT
Hands-on

TM-TPVN/HT
7/23/16

Day 4:
Aseptic Tank system

TM-TPVN/HT
7/23/16

Agenda: 4 days

Day 4: Aseptic Tank


08:00 08:15: Aseptic tank systems
08:15 08:45: Operations, processing parameters
10:00 10:30: Break
10:30 10:45: Technical data
10:45 11:00: Main components & functions
11:00 11:30: Process steps, activations
11:30 11:45: P&ID detailed tracing Use colored P&ID
11:45 12:00: Critical control points
12:00 13:00: Lunch
13:00 13:15: Cleaning
13:15 13:45: Trouble shooting & Alarm Handling
13:45 14:00: Recording
14:00 14:30: Break
14:30 15:00: Operation manual
15:00 15:15: Maintenance Aseptic Tank
15:15 15:30: Preventive maintenance system
15:30 15:45: Basic instructions to use Spare parts catalogue
15:45 16:15: Hands-on
16:30 17:00: Summary & Evaluation
TM-TPVN/HT
7/23/16

Machine Introduction

TM-TPVN/HT
7/23/16

Introduction Machine in processing line

TM-TPVN/HT
7/23/16

Machine Introduction Main components

TM-TPVN/HT
7/23/16

Machine Introduction Technical data

TM-TPVN/HT
7/23/16

Machine Introduction Technical data

TM-TPVN/HT
7/23/16

Machine Introduction Operations

Sterilizing
Cooling
Filling
Fill pipe
Emptying
CIP

TM-TPVN/HT
7/23/16

Process steps
Process cycle: Phases and Steps
Step 1 10: Pre-sterilization
Step 12 14: Cooling
Step 101 105: Production (Emptying)
Step 601 604: CIP (Full cleaning)
Step 501 502: Shutdown (Depressurize)

TM-TPVN/HT
7/23/16

Activation diagram

TM-TPVN/HT
7/23/16

Activation diagram

TM-TPVN/HT
7/23/16

Activation diagram

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 1 Drain 1.0 bar steam

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 2 Drain 2.7 bar steam

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 3 Pressurize

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 9 Heating

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 10 Sterilizing

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 12 Cooling 1

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 13 Cooling 2

TM-TPVN/HT
7/23/16

Machine steps Pre-sterilization


Step 14 Condensate drain

TM-TPVN/HT
7/23/16

Machine steps Production

TM-TPVN/HT
7/23/16

Machine steps Production


Step 101 Ready for Production

TM-TPVN/HT
7/23/16

Machine steps Production


Step 102 Filling to Low Level

TM-TPVN/HT
7/23/16

Machine steps - Pre-sterilization


Step 103 Filling above Low Level

TM-TPVN/HT
7/23/16

Machine steps Production


Step 104 Filling pipe to EVC

TM-TPVN/HT
7/23/16

Machine steps Production


Step 105 Ready for Emptying

TM-TPVN/HT
7/23/16

Machine steps CIP

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 601 Pressurizing

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 603 Circulation tank

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 701 (604) Flip 1 V101-V125

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 702 (604) Flip 2 V120-V600

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 703 (604) Flip 3 V126-CR127

TM-TPVN/HT
7/23/16

Machine steps CIP


Step 704 (604) Flip 4 V101A

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 200 Idle

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 201 Deact. V101F

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 202 Drain condensate

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 203 Act. V101G

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 204 Act. V101D

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 205 Act. V164

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 206 Deact. V164

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 207 Deact. V101D

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 208 Prepare to drain.

TM-TPVN/HT
7/23/16

Sub Program 1 Filling Sequence


Step 209 Flush out product

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 300 Idle

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 301 Prepare line for acting V121

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 302 Act V121

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 303 Product. line open to drain

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 304 Product. line close to drain

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 305 Flush out product Drain

TM-TPVN/HT
7/23/16

Sub Program 2 Filling/Emptying line


Step 306 Flush out product Steam rinse

TM-TPVN/HT
7/23/16

Critical control points (CCP)

TM-TPVN/HT
7/23/16

Critical control points (CCP)

Pre-sterilization:

Production:

TSL140, TSL160,TSL150, PSL130

Shutdown

TSL101, TSL140, TSL160, TSL170, TSL150


SA filter cartridge counter

PSL130

CIP

TT150, LT110, TSL140

TM-TPVN/HT
7/23/16

Critical control points (CCP)


Exchange of the filter cartridges
The

PLC system is counting each pre-sterilizing step and will


give an alarm after 50 pre-sterilizing cycles.
Replacements:
Exchange filter cartridge B with a new filter cartridge
Move the old filter cartridge B to position A
Discard the old filter cartridge A

TM-TPVN/HT
7/23/16

Lunch

TM-TPVN/HT
7/23/16

Care and Cleaning

TM-TPVN/HT
7/23/16

Care and Cleaning


Verify Cleaning

Daily check

Check recorder to see if cleaning completed correctly


Lye/Acid concentration

TM-TPVN/HT
7/23/16

Care and Cleaning


Verify Cleaning

Recommended check

Regularly weekly/monthly verify the cleaning result at critical points


such as V101 .
Visual check for any product residues after cleaning.
Make a swab test to check to cleaning result.
If necessary, adjust the cleaning circulation time and detergent
concentration.

TM-TPVN/HT
7/23/16

Care and Cleaning


Cleaning CPP

V101 inside
V121 inside
Agitator propeller Visco Jet
Spray balls

TM-TPVN/HT
7/23/16

Care and Cleaning


Recommended detergents & Concentration

TM-TPVN/HT
7/23/16

Care and Cleaning


External cleaning

TM-TPVN/HT
7/23/16

Alarms & Troubleshooting

TM-TPVN/HT
7/23/16

Alarm list

TM-TPVN/HT
7/23/16

Alarm list

TM-TPVN/HT
7/23/16

Alarm list

TM-TPVN/HT
7/23/16

Alarm list

TM-TPVN/HT
7/23/16

Alarm list

TM-TPVN/HT
7/23/16

Operation Manual

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Menu tree

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Overview menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Operating menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Start check menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Process value menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


PID menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


PID parameters menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Alarm list menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Trend diagram menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Service menu 1

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Service menu 2

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Force select menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Temperature guard menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Level guard menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Pressure guard menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Recipe edit menu

TM-TPVN/HT
7/23/16

Operation Manual - TPOP


Agitation speed

TM-TPVN/HT
7/23/16

Operation Manual Preparation


General check points

TM-TPVN/HT
7/23/16

Operation Manual Operation


General check points

TM-TPVN/HT
7/23/16

Operation Manual Operation


Tank operation

Start tank (Pre-sterilization)


Stop tank
Emergency Stop
Agitation
Emptying Manual emptying
Cleaning of tank

TM-TPVN/HT
7/23/16

Operation
Start tank (Pre-sterilization)

Selection/setting prior to start


Check the sterile air filter if it need to be replaced
Do not start when personnel is present in risk area

Start conditions:
Check
Check

no alarms are active


conditions in Start check menu

TM-TPVN/HT
7/23/16

Operation
Start tank (Pre-sterilization)

Start/Command sequence
Select Operation menu
Press Pre-sterilizing button
Press Start button (3)

(2)

TM-TPVN/HT
7/23/16

Operation
Start tank (Pre-sterilization)

Checks/Operation during sequence


Step No. and actual program
Watch out for any alarms

step are indicated

Sequence completed
Go to step 101 Ready for Filling
If necessary, reset load cell (Service

menu 1)

TM-TPVN/HT
7/23/16

Operation
Filling & Emptying

Sequence
When

product is detected at inlet, filling of the tank starts.

When

level reached above Low Level set point, the outlet


pipe will be filled with product.
If the filling stop before Low Level is reached and no more
product is available, apply temporary Low Level set point to
make the program advance:
o

At the Level guard LS 110 menu, set the Low Level set point
lower than the normal value. Program will advance to step 103,
then104.

TM-TPVN/HT
7/23/16

Operation
Filling & Emptying
Step advance to 103

TM-TPVN/HT
7/23/16

Operation
Filling & Emptying

Sequence
After

step 104 completed, Emptying sequence is ready and


will start when filling machines request.

Filling

and Emptying sequence can take place at the same

time:
Filling sequence stops when tank gets high level or
product is not available at inlet.
Emptying sequence stops when tank gets empty or FMs
stop requesting product.

TM-TPVN/HT
7/23/16

Operation
Manual emptying

Start sequence

Stop sequence

TM-TPVN/HT
7/23/16

Operation
Agitation (Option)

Conditions
In

production, agitator is running with speed relevant to tank


level.
During CIP, the agitator will run during specific steps
regardless of operator selections and tank level.

Start sequence

Stop sequence

TM-TPVN/HT
7/23/16

Operation
Stop tank

Sequence conditions
If

Finalize is ordered in program step Heating or Sterilizing,


the tank will bi cooled down before function is activated.

The

Finalize function can not be ordered when theres


product in the tank.
If Abort is chosen, the sequence is stopped at once.

TM-TPVN/HT
7/23/16

Operation
Hold process

Hold command (Pause)


Go to Operation menu
Select function to Hold
Press Hold button

TM-TPVN/HT
7/23/16

Operation
Restart

Restart after Pause


Go to Operation menu
Select function to restart
Press Restart button

TM-TPVN/HT
7/23/16

Operation
Cleaning (CIP)

General
Tetra

Alsafe must be cleaned before Pre-sterization and


Production.

The

system must be cleaned direct after each production


and if the system has been closed down for a lone time.
The system must be cleaned with lye every cleaning time
and at least one a week with lye and acid.

TM-TPVN/HT
7/23/16

Operation
Cleaning (CIP)
Conditions (in Start check menu)
The tank is empty
No function is selected

or program is in step Ready for

Filling 101
The CIP unit is not occupied

TM-TPVN/HT
7/23/16

Operation
Cleaning (CIP)
Sequence commands
Start

Hold

/ Abort

TM-TPVN/HT
7/23/16

Operation
Emergency Stop

Sequence
Push

EMERGENCY STOP button to stop the tank


immediately

Push and release EM button


The program will go to Step 0 if its in following sequences:
Pre-sterilizing: Step 1 14
Depressurizing: Step 501 502
The program will continue from where it was stopped if its in

following sequences:
Production: Step 101 105
CIP: Step 601 632
(Need to push restart button to continue)

TM-TPVN/HT
7/23/16

Shutdown
Plant shutdown sequence

Check points
Close air supply
Close steam supply
Close water supply
Switch OFF the main

switch in Control panel

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Maintenance Manual

Valves
Sensors and transmitters
Tanks and vessels
Other components

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Preventive maintenance system

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Preventive maintenance system

Preventive maintenance recommendations


specifies:
Activities (what to do)
Service interval (when to do)
Spare parts (what to change)

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Spare parts list

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Components instructions

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Troubleshooting

Mechanical system
Electrical system
Automation

TM-TPVN/HT
7/23/16

Maintenance Aseptic tank


Hands-on

TM-TPVN/HT
7/23/16

Final

Summary, Q&A
Evaluation Test

TM-TPVN/HT
7/23/16

Thank you!

TM-TPVN/HT
7/23/16