REAL TIME RADIOSCOPY

IMAGE
PROCESSING
REAL TIME
RADIOSCOPY (RTR)

ONISING RADIATION PASSED THROUGH AN OBJECT


RODUCE AN IMAGE ON A VIDEO MONITOR. IMAGE
IEWED IN CONCURRENT IRRADIATION.
-RAY IMAGE IS CONVERTED INTO A DIGITAL IMAGE
HROUGH A LONG CHAIN CONSISTING OF AN IMAGE
NTENSIFIER, OPTICAL LENS SYSTEM, VIDEO CAMER
ND ANLOG TO DIGITAL CONVERTER ELECTRONICS.
-RAY VOLTAGES - 50 TO 320 Kv
-RAY IMAGE - POSITIVE - SIZE LIMITED TO I.I.
SCREEN DIA (150 TO 400 mm)

REAL TIME RADIOSCOPY AND


DIGITAL IMAGE PROCESSING
TECHNIQUES FOR ON LINE
INSPECTION OF WELDS IN
BOILER TUBES
BY

R.J.PARDIKAR
NDT / BHEL
TIRUCHIRAPALLI - 14

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE INTENSIFIER TUBE SYSTEM

CONVERTS THE X-RAY IMAGE TO LIGHT THEN TO


ELECTRONS AND BACK TO LIGHT ON THE OUTPUT
SCREEN OF THE TUBE.
PRIMARY SCREEN
- CAESIUM IODIDE (CsI)
EFFICIENT WITH X-RAY
ENERGIES 30 - 320 Kv
IMAGE RESOLUTION - X2 OR X3
LUMINATION GAIN
- 3000 - 10,000
SUITABLE FOR MOST CCTV
CAMERAS

REAL TIME RADIOSCOPY


IMAGE PROCESSING

WHY REAL TIME RADIOSCOPY ON


TUBE WELDS?
A. INTRODUCTION OF SEMI-AUTOMATIC MIG
WELDING FOR BOILER TUBES IN 1970S.
B. TURN OVER PER SHIFT HIGH - 100 Jts.
C.CONVENTIONAL RADIOGRAPHY TIME
CONSUMING - COULD NOT COPE WITH
PRODUCTION SCHEDULE
D. SEGREGATION OF ACCEPTABLE TUBE WELDS
SIMPLE - FOR IMMEDIATE ASSEMBLY AFTER
EXAMINATION.

REAL TIME RADIOSCOPY


IMAGE PROCESSING

MERITS OF RADIOSCOPY

A. IMMEDIATE RESULTS - CONCURRENT WITH


EXAMINATION
B. FEED BACK ON WELDING PERFORMANCE MODIFICATION OF WELDING PARAMETERS POSSIBLE
C. COST EFFECTIVE IN THE LONG RUN ( FILMS SAVED)
D. DYNAMIC IMAGING OF FLAWS
E. ALIGHNMENT OF X-RAY BEAM FOR LACK OF FUSION
BY SWIVELLING ARRANGEMENT
F. STATIC VIEWING ON STOP-START CRITICAL AREA
G. REMOTE VIEWING , INCREASED SAFETY

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE QUALITY

ASSESSED IN TERMS OF :-

SHARPNESS
CONTRAST
NOISE LEVEL

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE UNSHARPNESS

THE DEFENITION OF AN X-RAY TELEVISION IMAGE IS


CONTROLLED BY :
THE INHERENT UNSHARPNESS OF PRIMARY
CONVERSION SCREEN (TYPICALLY - 0.3 mm)
GEOMETRIC UNSHARPNESS DUE TO X-RAY TUBE
FOCAL SPOT SIZE AND PROJECTIVE MAGNIFICATION
THE SIZE OF THE PIXEL MATRIX IN RELATION TO THE
LENGTH OF THE WELD IMAGED (TYPICALLY - 0.2 mm)
THE LINE RASTER OF THE TELEVISION DISPLAY (ONE
LINE PAIR - 0.4 mm)
IMAGE INTENSIFIER RESOLUTION VARIES WITH
ELECTRONIC MAGNIFICATION
VARIES FROM CENTRE TO EDGE

REAL TIME
RADIOLSCOPY IMAGE
PROCESSING
DEFECTS

1.
2.
3.
4.
5.
6.

IN STBW

BURN THROUGH
WIRE STUB
INCOMPLETE PENETRATION
LACK OF FUSION
GAS HOLE OR POROSITY
SURFACE DEFECTS

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE CONTRAST

FILM RADIOGRAPHY : CONTRAST ENHANCEMENT


FACTOR - 4 TO 6

RTR

CONTRAST

: NO INCREASE IN

RTR WITH IMAGE PROCESSING:


CONTRAST ENHANCEMENT PROGRAMMES FOR
BOTH OVERALL AND LOCAL - AVAILABLE

REAL TIME
RADEIOSCOPY IMAGE
PROCESSING

IMAGE NOISE

NOISY IMAGE :

PRODUCED BY SMALL QUANTA OF X-RAY


OBSCURES IMAGE DETAILS

WAYS TO MINIMISE NOISE IMAGE:


1. USE PRIMARY CONVERSION SCREEN
2. USE HIGH OUTPUT X-RAYS (HIGHER Kv)
3. SIGNAL INTEGRATION OVER SEVERAL SECS.

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE QUALITY REQUIREMENTS

WIRE TYPE IQI (CONVENTIONAL)


- NOT SATISFACTORY
- IQI SENSITYVITY - GOOD
- DEFECT SENSITIVITY - POOR

DUPLEX WIRE IQI


- TYPE III A OF BS 3971 : 1985
- HAS GOOD IQI AND DEFECT SENSITIVITY

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE PROCESSING

CONVERTS ANALOG SIGNAL TO DIGITAL


TV SIGNAL SAMPLED AND CONVERTED TO 1
BYTE DEEP DATA WORD
IMAGE SIZE 512X512=262144 PIXELS
A BLACK & WHITE IMAGE HAVE 262144 GREY
LEVELS
INTENSITY OF I PIXEL REPRESENTS 1 GREY
LEVEL
GREY LEVEL OF A PIXEL - 0 T0 255
INPUT SIGNAL DIGITALLY INTEGRATED OVER
SEVERAL VIDEO FRAMES

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE PROCESSING FOR


WELD INSPECTION

A) QUANTUM NOISE REDUCTION BY


FRAME INTEGRATION
B) THICKNESS EQUALISATION ACROSS
THE IMAGE
C) CONTRAST ENHANCEMENT (LOCAL /
OVERALL)
D) IMAGE CRISPENING BY EDGE
ENHANCEMENT

REAL TIME
RADIOSCOPY IMAGE
PROCESSING

IMAGE DATA ANALYSIS

PURPOSE :

- TO GET HIGH CONTRAST AND


- RESOLUTION OVER THE RAW IMAGE

STEPS :
- DIGITISATION OF ANALOG VIDEO IMAGE BY
ADC
- IMAGE ENHANCEMENT USING PROCESSING
SOFTWARE
- RECONVERSION OF DIGITAL SIGNAL TO
ANALOG IMAGE BY ADC

REAL TIME RADIOSCOPY


IMAGE PROCESSING

REAL TIME X-RAY IMAGING SYSTEM


FOR BOILER TUBES

1.
2.
3.
4.
5.
6.
7.

SYSTEM CONFIGURATION

TUBE HANDLING SYSTEM


X-RAY GENERATOR
IMAGE INTENSIFIER
OPTICAL COUPLING SYSTEM
VIDEO CAMERAS
IMAGE PROCESSOR
VIDEO MONITOR

REALTIME RADIOSCOPY
IMAGE PROCESSING

HANDLING DONE FROM RTR CONTROL


ROOM
1. TUBE STAND - TO STORE WELDED JTS.
2. TUBE MOVEMENT SYSTEM TO MOVE
THE WELD INTO THE RADIATION
CHAMBER
3. TUBE ROTATION SYSTEM

TUBE HANDLING SYSTEM

REAL TIME RADIOSCOPY


IMAGE PROCESSING

X-RAY GENERATOR

320 Kv - CONSTANT POTENTIAL

- DUAL FOCUS 3X3 mm OR 1.2X1.2 mm


- TUBE CURRENT - MAX. 10 Ma

IMAGE INTENSIFIER

INPUT SCREEN DIA


OUTPUT SCREEN DIA
RESOLUTION
VIEWING SCREEN

: 220 mm
: 20 mm
: 48 LINE PAIR / CM
: P 20

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE PROCESSING SOFTWARE

FOR IMAGE IMPROVEMENT


POINT TRANSFORMATION
GREY LEVEL MANIPULATION
TWO DIMENSIONAL TRANSFORMATION
MATHEMATICAL PROCEDURE
TRANSFORMS ORIGINAL IMAGE INTO
FILTERED IMAGE

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE PROCESSING SOFTWARE

DISPLAY / SAVE IMAGES & SUB-IMAGES


ACQUIRE IMAGES FROM X-RAY
HISTOGRAM
SCALING
GRADIENTS - SOBEL, LAPLACE, ROBERT
CONVULTION
ANNOTATION

REAL TIME RADIOSCOPY

IMAGE PROCESSING

FILTERS :
1. LOWPASS 2. HIGHPASS 3. MEDIAN
4. MODE 5. EXPONENTIAL 6. WALLIS
7. LAPLACIAN 8. GAUSS 9. LOGRITHMIC
IMAGE ADDITION / SUBTRACTION
ZOOM
BINARY
LINEAR INTENSITY MAPPING
ACQUIRING & ENHANCING TIME : 20 TO 120 SECS.
DEPENDING ON THE COMBINATION OF SOFTWARE

REAL TIME RADIOSCOPY


IMAGE PROCESSING

IMAGE PROCESSING
HARDWARE

1. PERSONAL COMPUTER
MAIN MEMORY - 64 MB RAM
HARD DISC
4 GB
2. DT 2851 - FRAME GRABBER BOARD
3. DT 2858 - FRAME PROCESSOR BOARD
4. OPTICAL DISC

REAL TIME RADIOSCOPY


IMAGE PROCESSING

CONCLUSION

DIGITAL IMAGE PROCESSING - AN ESSENTIAL


TOOL IN RTR EVALUATION

RELIABLE DEFECT DETECTION GUARANTEED


REDUCES HUMAN ERRORS IN INTERPRETATION
CAN SUBSTITUE FILM RADIOGRAPHY
SATISFIES NATIONAL & INTERNATIONAL CODES

INCREASES PRODUCTIVITY

REAL TIME RADIOSCOPY


IMAGE PROCESSING
EDGE

ENHANCEMENT

REMOVE HIGH AND LOW SPATIAL FREQUENCY


DATA FROM AN IMAGE BY USING DIGITAL
FILTERING
SPECIMEN REPRESENTS SUDDEN VARIATION IN
GREY LEVEL
THE GREY VARIATION CAN BE BOOSTED USING
FILTERS
EDGE ENHANCEMENT CAN SHARPEN THE
REPRESENTATION OF INTERNAL STRUCTURE

REAL TIME RADIOSCOPY


IMAGE PROCESSING

CONTRAST ENHANCEMENT

VIDEO SIGNAL DYNAMIC RANGE IS LIMITED


BECAUSE OF NOISE SUPRESSION TECHNIQUE
SPECIAL FUNCTION IS USED TO REPOSITION THE
DIFFERENT GREY VALUES BETWEEN BLACK AND
WHITE
BY MODIFYING THE BRIGHTNESS LEVELS, THE
HIGH FREQUENCY COMPONENTS ARE EMPHASISED
AND LOW FREQUENCY COMPONENTS ARE
ATTENUATED
THE ORIGINAL IMAGE DATA IS NOT MODIFIED BUT
THE DISPLAY ALONE IS SUITABLY MODIFIED

REAL TIME RADIOSCOPY


IMAGE PROCESSING
PROJECTIVE

MAGNIFICATION

THE IMAGE OF DETAIL IN THE WELD IS


PROJECTED LARGER THAN TRUE SIZE ON TO
THE SCREEN WITHOUT SIGNIFICANT LOSS IN
IMAGE SHARPNESS
MICROFOCAL X-RAY TUBE IS REQUIRED

PROJECTIVE MAGNIFICATION RESULTS IN


CONSIDERABLE REDUCTION IN THE PROPORTION OF
SCATTERED RADIATION REACHING THE DETECTOR
SCREEN AND IMPROVES THE CONTRAST OF IMAGE

THE MAGNIFICATION OF IMAGE MEANS THAT


THE NUMBER OF PIXELS ON SCREEN COVER
SMALLER AREA OF THE WELD

REAL TIME RADIOSCOPY


IMAGE PROCESING
PROJECTIVE

MAGNIFICATION

TO OBTAIN PROJECTIVE MAGNIFICATION OF (SAY)


5X, THE DETECTOR-TO-WELD DISTANCE MUST BE
FIVE TIMES LARGER THAN FOCUS TO WELD
DISTANCE. THIS MAY BE PHYSICALLY DIFFICULT .
RESULTS IN POOR WELD COVERAGE.
SLOWS THE SPEED OF INSPECTION.
IN RTR OF STB WELDS MAGNIFICATION OF THE
ORDER OF 1.3 TO 1.5 IS NORMAL.
DUAL LENS SYSTEM WITH MOTORISED ZOOM LENS
PROVIDES ADDITIONAL MAGNIFICATION OF 2X.

REAL TIME RADIOSCOPY


IMAGE PROCESSING
PROJECTIVE

MAGNIFICATION

THE UNSHARPNESS RELATIVE TO THE ACTUAL


SIZE OF THE SPECIMEN IS REDUCED.
HIGH MAGNIFICATION ABOVE 2 IS PRACTICABLE
ONLY WITH MICROFOCAL X-RAY EQUIPMENT.
HOWEVER POTENTIALLY A VERY POWERFUL
TECHNIQUE.

THANK

YOU