SDH Introduction

A brief description of the dedicated SOH bytes (see ITU-T Recommendation G.707 for more information):
A1: Frameword (11110110).
A2: Frameword (00101000).
J0: Regenerator Section Trace [See the Path Trace property sheet].
B1: BIP-8 checksum for the regenerator section [See the Performance chapter].
B2: BIP-24 checksum for the multiplex section [See the Performance chapter].
MS1 and MS2: Media Specific bytes. Used by Nera equipment for Radio Protection Switching communication.
MS3: Media Specific byte. Used by Nera equipment for:
RF-id: [See the Path Trace property sheet].
Remote Reset: [See the Remote Reset property sheet].
ATPC: control signal for ATPC. [See the Power property sheet].
E/M-Wire for E1, E2 and F1. [See the SVCE Telephone property sheet]. E2 is not available for InterLink service telephone.
K1 and K2: Intended to be used for:
Multiplex Section - Automatic Protection Switching.
MS-RDI: Multiplex Section-Remote Defect Indication.
S1: Synchronization status.
M1: Multiplex Section - Remote Error Indication (MS-REI). [See the Performance chapter]
SOH bytes available for user channels (64kb/s, 2Mb/s Wayside, DCC, SVCE telephone):
E1: Intended to be used as Orderwire for regenerator section termination. Default timeslot for SVCE telephone. Can be
used for SVCE telephone, 64kb/s or DCC.
E2: Intended to be used as Orderwire for multiplex section termination. Can be used for SVCE telephone, 64kb/s or DCC.
F1: Intended to be used for V.11 or G703 interfaces. Default timeslot for 64kb/s channels. Can be used for SVCE
telephone, 64kb/s or DCC.
D1-D3: Intended to be used as embedded control channel for regenerator section. Single bytes can be used for 64kb/s or
DCC Line. Multiple bytes can be used for DCC.
D4-D12: Intended to be used as embedded control channel for multiplex section. Single bytes can be used for SVCE
telephone, 64kb/s or DCC. Multiple bytes can be used for DCC.
NU: National Use. The use may be restricted by national regulations. Can be used for SVCE telephone, 64kb/s, DCC or
2Mb/s Wayside.
UN: Unused. Can be used for SVCE telephone, 64kb/s, DCC or 2Mb/s Wayside. The E1, E2 and F1 timeslots can be used
in conjunction with the E/M Wire (MS3 timeslot) when control signals are required (E.g. if using a PABX adapter on a SVCE
Board).

Interlink NL200x

**

**

Tsel = Backbone Trans Sulawesi


Tsel = Backbone Trans Jawa Bali

INTERLINK INDOOR MOUNTED

Interlink Split Mounted

Interface Baseband Board

Modem Board

TRANSCEIVER

INTERLINK INDOOR
MOUNTED

INTERLINK SPLIT MOUNT

SUPERVISORY BOARD

SVCE BOARD

Auxiliary Services Board

Alarm Display & Relay Board

Power Filtering Board

SmartMetro

Note: Max capacity for 1 rack is


4x63E1=252E1

SmartMetro Slot Assignment

SmartManager

Tsel: version 4.0.02

NetMaster

Oracle license:
-oracle standard edition one max 10 clients
-oracle standard max 5 clients
-oracle enterprise edition 10 max 10 clients
NetMaster license:
-one client included

Recent condition & future


plan

Recent Condition of SDH NERA mgt network


Application: NEW-NMS
software release: R7L01
Service area: Backbone Trans Jawa-Bali,several NEs' at Medan Inner
& Ambon
NE to manage: Interlink, Citylink, NL29x
Server-Client existing: Wismul(Server),Jakarta(TBS & Wismul),
Bandung, Semarang, Surabaya

Future Plan
Server 1
Application: NEW-NMS
software release: R7L01
Service area: Citylink & NL29x network only (Jawa-Bali-Mdn)
Location: Wismul
Server 2
Application: NET-MASTER
software release: R10F
Service area:Backbone Trans Jawa-Bali (Interlink)
Location: Data center, TBS
Server 3
Application: NET-MASTER
software release: R10F
Service area:Backbone Trans Sulawesi (Interlink)
Location: Data center, TBS

THANK YOU