You are on page 1of 34

Basics

1RBS = 3BTS (BTS covers 1 sector cell)

1RBS can handle up to 12 TRXs (1TRX means 1 frequency)

An MO is a logical representation of HW unit and SW of the BTS in the BSC

In most cases one TG handles one RBS

One TG can consist of up to 16 frequencies

TRU (RBS2000) stands for transceiver group, 1 TRU handles one frequency, which
consist of 8 timeslots, each timeslot needs 16kbps bandwidth

AXE BSC :

RL commands used for cell handling

RX commands used for managed object handling

Managed objects Block Diagram


1.Transceiver

Group (TG)
2.Central Function (CF)
3.Digital Path (DP)
4.Concentrator (CON)
5.Transceiver Controller (TRX)
6.Transmitter (TX)
7.Receiver (RX)
8.Interface Switch (IS)
9.Timing Function (TF)
10.Time Slots (TS)

DP
CF

TF

RX
TRXC
0

TX
TS
0

IS

( UP TO 16 TRXCs)

TS
7

8 TS

TS
7

8 TS

RX
TRXC
15

TX
TS
0

CON

Managed object block diagram RBS2000 (G12)

Managed object block diagram RBS200 (G01)

9702380

RBS 2000 family

RBS 2206 Hardware overview

DXU-21 Distribution Switch Unit

DXU

Central control unit for RBS

Flashcard makes it possible to change a faulty DXU card, without the need for loading RBS
software from the BSC

OMT is the RBS configuration tool. All the RBS configuration data and the software stored
in flash memory card (size: 32Mb). Configuration file: ldb.dbb.

Distribution Switch Unit Functions

CF Central Function: the control part of a TG. The BSC communicates with the CF using
layer 2 LAPD, address: TEI = 62.

CON LAPD concentration for RBS 2000.

IS Interworking Switch: system interface to the 2 Mbit/s link, connects time slots to
transceivers.

TF Timing Function, synchronization with PCM link and generates a timing reference for the
RBS.

DP Digital Path, Layer 1, each of the PCM systems terminating in TG has an associated
supervision object, the DP.

dTRU double Transceiver Unit

Contains 2 TRXs for transmission and reception of carriers.

built-in combiner with the possibility of combining two TX signals into


one output.

Prepared for RX diversity

dTRU - Transceiver Unit functions

TRXC The transceiver controller is controlling all the functions for


signal processing, Radio receiving and Radio Transmitting.

RX The receiver provides the


functionality for one transceiver.

TX The transmitter provides the radio frequency transmission


functionality on a time slot basis for eight TSs using different time
slot numbers.

radio

frequency

reception

CDU & CXU

Combiners (CDU)

Interface between the transceivers (TRU) and the antenna system.

Signals are filtered before transmission and after reception with bandpass
filters.

RBS 2206 maximum 3 CDU

CDU-F used for high capacity solutions (Baseband hopping)

CDU-G is the most common used, it can be configured either for high
capacity or high coverage. It supports synthesizer hopping

Configuration Switch Unit (CXU)

Distributes the RX signal from CDU to dTRUs

Built up SW controlled switches

Makes it possible to reconfigure a cabinet without cable moving

Other Hardware Units

Standard HW units

ACCU-01: AC connection unit


DCCU: DC Connection unit
FCU: Fan Control Unit
IDM Distributes the internal 24V+ DC power to all other units
PSU Power Supply unit
DC filter
Battery Fuse unit (outdoor cabinets)
Climate unit
EPC bus: optical cable bus, for alarm signaling

Optional HW units

ASU (Antenna Sharing unit) is for co-siting, when other cabinet used together with the
RBS 2206 in the same sector
BBS battery backup system from external cabinet
ddTMA improves the receiver sensitivity, duplexing the RX and TX signals to the same
feeder cable. Power supply provided for TMA by bias injector.
DF: over voltage protector for external alarm cables
ESB is used for TG synchronization to expand one RBS cabinet with another RBS in the
same cell
HCU contains 3 hybrid combiners. Each hybrid combines 2 RF signals, delivered from
2dTRU into one
Battery backup, DC/DC converter, DC filter, Smoke detector, Transport module

RBS 2206 configurations with CDU-G

TG sync & Cascade mode

TG sync: More than 1 cabinet in one cell


Master / Slave mode used (RXMOI: TFMODE
parameter)
TFCOMPPOS is the distribution delay between the
master and slave TG , value depends on the
cablelenght. OMT able to calculate.
Cascade mode used when only 1 PCM available
for 2 RBSs

1 PCM
Cascade
mode

2 PCMs no
cascade mode

RBS0

RBS1

RBS0

RBS1

TFMODE

TEI

62

61

62

62

TFCOMPOSS

OMT

OMT

OMT

OMT

2 RBS in cascade mode with TG


sync

Cell data definition

A cell can be internal or external.

External cells: certain data must be known in order to carry out a handover from a
cell in its own BSC to a cell controlled by another BSC.

Useful cell handling commands:

RLDEI:CELL=cell, CSYSTYPE=[GSM900, GSM1800, GSM800, GSM1900], ext;


RLDEC: CELL=cell, CGI=cgi, BSIC=bsic, BCCHNO=bcchno,
NEWNAME=newname, AGBLK=agblk, MFRMS=mfrms, BCCHTYPE=bcchtype,
FNOFFSET=fnoffset, XRANGE=xrange;
Cell Power data configure, print: RLCPC, RLCPP
Cell Frequency and hopping data print: RLCFC, RLCHP
Channel group configuration, change RLDGI, RLCCC
Cell data print: RLDEP:CELL=xxxx;
Cell status: RLSTP:CELL=xxxx;
Cell Resource RLCRP:CELL=xxxx,DETAIL;
Cell removing: RLDEE:CELL=xxxx;
Cell neighbor relation print: RLNRP:CELL=xxxx,cellr=all,nodata;

BTS logical configuration


RBS
A-bis
TG=Transceiver Group
CF=Central Function
IS=Interface Switch
TF=Timing Function
CON=Connector

RXOTG-99
RXODP-99-0
RXODP-99-1
RXOCON-99-0

DXU (hw)
RXOIS-99

RXOTF-99
RXOCF-99

TRU (hw)
RXOTRX-99
RXOTX-99-0
RXORX-99-0

TRU (hw)
RXOTRX-99
RXOTX-99-1
RXORX-99-1

RXOTS-99-0-0
RXOTS-99-0-1
RXOTS-99-0-2
RXOTS-99-0-3
RXOTS-99-0-4
RXOTS-99-0-5
RXOTS-99-0-6
RXOTS-99-0-7

RXOTS-99-1-0
RXOTS-99-1-1
RXOTS-99-1-2
RXOTS-99-1-3
RXOTS-99-1-4
RXOTS-99-1-5
RXOTS-99-1-6
RXOTS-99-1-7

DP=Digital Path
TRX = Transceiver
TX = Transmission
RX=Receiver
TS=Timeslot

Managed objects definition

RXMOI:MO=RXOTG-99,COMB=HYB,RSITE=MUCSAROCSOGE, SWVER=B4402R009V;
RXMOC:MO=RXOTG-99,FHOP=SY,TRACO=POOL;
RXMOC:MO=RXOTG-99,CONFACT=2,ABISALLOC=FLEXIBLE,CONFMD=MINDIST,AHOP=OFF;
RXMOC:MO=RXOTG-99,ABIS64KTHR=0;
RXMOI:MO=RXOTF-99,TFMODE=SA;
RXMOI:MO=RXOCF-99,TEI=62,SIG=CONC;
RXMOI:MO=RXOIS-99;
RXMOI:MO=RXOCON-99,DCP=64&&87;

RXMOI:MO=RXOTRX-99-0,TEI=0,DCP1=178,DCP2=179&&186;
RXMOC:MO=RXOTRX-99-0,CELL=41772A,SIG=CONC;
RXMOI:MO=RXORX-99-0,RXD=AB,BAND=GSM900;
RXMOI:MO=RXOTX-99-0,BAND=GSM900,MPWR=47;
RXMOC:MO=RXOTX-99-0,CELL=41772A;

RXMOI:MO=RXOTS-99-0-0&&-7;

RXMOI:MO=RXOTRX-99-1,TEI=1,DCP1=187,DCP2=188&&195;
RXMOC:MO=RXOTRX-99-1,CELL=41772A,SIG=CONC;
RXMOI:MO=RXORX-99-1,RXD=AB,BAND=GSM900;
RXMOI:MO=RXOTX-99-1,BAND=GSM900,MPWR=47;
RXMOC:MO=RXOTX-99-1,CELL=41772A;

RXMOI:MO=RXOTS-99-1-0&&-7;

Managed Objects States

Cell activation

1. Connect transmission

RXAPI:MO=RXOTG-1,DEV=RBLT3-33&&-63,DCP=1&&31;
RXAPP:MO=RXOTG-1;
DTBLE:DIP=1RBL3;
BLODE:DEV=RBLT3-33&&-63;

2. Deblocking of managed objects

RXESI:MO=RXOTG-0, SUBORD;
(It can take a few minutes, especially when flash card is not pre-loaded with the BTS software)

3. Activate Cell

RXBLE:MO=RXOTG-0, SUBORD;

RLSTC:CELL=41772A,STATE=ACTIVE;

4. Check cell data

RXCDP:MO=RXOTG-1;
RLCRP:CELL=41772A;
RXMFP:MO=RXOTG-1,SUBORD,FAULTY;

Check cell resources

RLCRP:CELL=ALL; shows some cells are down:


<RLCRP:CELL=ALL;
CELL RESOURCES
CELL
BCCH
FUR138C
1
FUR138B
1
FUR138A
1
GA4134C
0
GA4134B
0
GA4134A
0
FUR138A
1
PSA135C
1
PSA135B
1

CBCH SDCCH NOOFTCH


1
7 12- 24
1
7 14- 28
1
7 14- 28
0
0
0
0
0
0
0
0
0
1
7 14- 28
1
7 14- 28
1
7 14- 28

RLCRP:CELL=ALL; shows some cells are down.


RLCRP lists only cells in active state
Command can be used RLCRP:CELL=ALL,detailed; switch, for more information
When using this command for one cell detailed information will be printed automatically

Check alarms and find TG

An easy way to recognize a cell without all resources available to run ALLIP or
ALLIP:PRCA=43;
<allip:prca=43;
ALARM LIST
A2/APT "GABSC41_E000B00" 122 040329
2152
CELL LOGICAL CHANNEL AVAILABILITY SUPERVISION
CELL
SCTYPE
CHTYPE
CHRATE
SPV
GA4134C
OL
TCH
FR
1
TCH
FR
2
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT
MO
RXOCF-15
END

RSITE
ALARM SLOGAN
WILTON_HOSPITAL LOCAL MODE

Find out which TG is connected to the cell, use RXTCP:cell=GA4134C,moty=RXOTG;


<rxtcp:cell=GA4134c,Moty=rxotg;
RADIO X-CEIVER ADMINISTRATION
TG TO CHANNEL GROUP CONNECTION DATA
MO
RXOTG-204
END

CELL
GA4134C
GA4134C

CHGR
0
1

Re-activate the cell


The workaround in this case to halt cell, block and take MOs out of service, and then
activate everything again.
Halt the cell (Cell restriction active alarm will present):
RLSTC: CELL=GA4134C,STATE=HALTED;
Block and take out of service MOs for TG:
RXBLI: MO=RXOTG-204,SUBORD,FORCE;
RXESE: MO=RXOTG-204,SUBORD;
Take in service and deblock MOs for the TG:
RXESI: MO=RXOTG-204,SUBORD; (This command needs a few minutes to be executed)
RXBLE: MO=RXOTG-204,SUBORD;
Activate cell:
RLSTC: CELL=GA4134C,STATE=ACTIVE;

Check resources
<rlcrp:cell=GA4134C;
CELL RESOURCES
CELL
GA4134C
CHGR
0

BCCH
1

CBCH
0

SDCCH
8

NOOFTCH
27- 54

BPC
6017

CHANNEL
TCH-1794
TCH-11749
TCH-11748

CHRATE
FR
HR
HR

SPV
1,2,3
1,3
1,3

STATE
IDLE
IDLE
IDLE

959

TCH-2529
TCH-13219
TCH-13218
TCH-2530
TCH-13221
TCH-13220
TCH-2531
TCH-13223
TCH-13222

FR
HR
HR
FR
HR
HR
FR
HR
HR

1,2,3
1,3
1,3
1,2,3
1,3
1,3
1,2,3
1,3
1,3

BLOC
BLOC
BLOC
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE

ICMBAND
1
1
1

CHBAND
800
800
800

64K
NONE

.
.
.

960
961

EGPRS
1
1
1
1
1
1

800
800
800
800
800
800

EGPRS
EGPRS

.
.
.
END

Check available resources for the alarmed cell with RLCRP:cell=GA4134C;

Verify BPC
<rlbdp:cell=GA4134C;
CELL CONFIGURATION BPC DATA
CELL
GA4134C
CHGR
0
1
END

NUMREQBPC
8
24

NUMREQEGPRSBPC
0
3

NUMREQCS3CS4BPC
0
0

TN7BCCH
GPRS

The number of BPC should be the same as the sum of the resources.
BPC = BCCH(1) + TCH (27) + SDCCH/8 (8/8) = 29 <> 32
CHGR: a group of frequencies handled in the same way within one cell. Channel
group 0 contains the Broadcast Control Channel (BCCH)
1 BPC (Basic Physical Channel) means 1 timeslot in 1 carrier.

Check the configuration of the TG


<rxcdp:mo=rxotg-204;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT CONFIGURATION DATA
MO
RXORX-204-0
RXORX-204-1
.
MO
ICM
.
RXOTS-204-9-1
RXOTS-204-9-2
RXOTS-204-9-3
.
MO
RXOTX-204-0
RXOTX-204-1
.
RXOTX-204-8
RXOTX-204-9
RXOTX-204-10
.
MO
RXODP-204-0

RESULT
CONFIG
CONFIG
.
RESULT

ARFCN
HOP
HOP
.
ARFCN

CONFIG
BLOCKED
BLOCKED
.
RESULT
CONFIG
CONFIG
.
CONFIG
CONFIG
CONFIG
.
RESULT
CONFIG

HOP

INSUFFICIENT TRX EQUIPMENT


END

.
ARFCN
206
HOP
.
HOP
HOP
203
.
SBITS

MISMATCH
NONE
NONE
.
TXAD TN
4
.
TXAD
2
9
.
3
4
0
N1
320

BPC

CHCOMB

960

OFFS

TCH

BSPWR
45
45

C0F
YES
NO

MISMATCH
NONE
NONE

43
43
43

NO
NO
YES

NONE
NONE
NONE

N3

N4

XRA
NO

ON

Check MO state
<rxmsp:mo=rxotg-204,SUBORD;!status BTS!
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT STATUS
MO
RXOTG-204
RXOCF-204
...
RXOTS-204-9-2
RXOTS-204-9-3
...

STATE
OPER
OPER

BLSTATE

BLO
0000
0000

BLA
0000
0000

LMO

BTS
STA
STA

CONF

COM
COM

MBL
MBL

0000
0000

0202
0202

0940
0940

DIS
DIS

UNCONF
UNCONF

The command RXMSP with the parameters SUBORD give us the information about the
status of all the MO in the TG. There are two Time slots (RXOTS-204-9-2 & RXOTS-204-93) manually block.
BLSTA
TE

DESCRIPTION

BLL

Load in progress. The Managed


Object may be blocked or in
operation.

BLT

Blocked due to testing.

MBL

Manually blocked.

BLO

Automatically blocked.

BLA

Blocked due to activity needed.

Check E1 configuration
APUSAGE

<RXAPP:MO=RXOTG-204;
RADIO X-CEIVER ADMINISTRATION
ABIS PATH STATUS
MO
RXOTG-204
DEV
RBLT3-2904

RBLT3-2920
3
RBLT3-2921
6
7
RBLT3-2922
RBLT3-2923
RBLT3-2924
RBLT3-2925
RBLT3-2926

RBLT3-4896
11
RBLT3-4897
RBLT3-4898
RBLT3-4899
RBLT3-4900

RBLT3-4914
RBLT3-4915
RBLT3-4916
RBLT3-4917
END

DCP
287

APUSAGE
MPLEX16
MPLEX16
MPLEX16
MPLEX16

APSTATE
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA

64K
NO
NO
NO
NO

TEI

303

CONC

TRXC SIGNAL

NO

304

CONC

CF/TRXC SIGNAL

NO

62

305
306
307
308
309

UNCONC
UNCONC
UNCONC
UNCONC
UNDEF

SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
IDLE

YES
YES
YES
YES
YES

CONC

TRXC SIGNAL

NO

2
3
4
5

UNDEF
UNDEF
UNDEF
UNDEF

IDLE
IDLE
IDLE
IDLE

NO
NO
NO
NO

19
20
21
22

UNCONC
UNCONC
UNCONC
UNCONC

SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA

YES
YES
YES
YES

10

DESCRIPTION

MPLEX16

voice

CONC

TRX/CF Signaling

UNCONC

IF 64K = YES then EDGE

UNDEF

Not defined. Not in service

APUSAGE

CONFIGURATION

MPLEX16

4 VOICE TS = 1 RBLT3

CONC

4 TRX = 1 RBLT3

UNCONC

1 EDGE TS = 1 RBLT3. General 9


per site (3 sectors site)

Check DIP state

In case when there is no traffic at all of the cells connected to one site it might be transmission
problem. Check which DIP is connected to the devices with NTCOP:SNT=ALL;
SNT
ETM2-0

SNTV SNTP
1 XM-0-0-2
21RBL3
42RBL3
3RBL3
24RBL3

51RBL3
12RBL3
33RBL3
11RBL3
12RBL3

DIP DEV
SNTINL
0RBL3 RBLT3-0&&-31
0
RBLT3-672&&-703
1
RBLT3-1344&&-1375
2
RBLT3-96&&-127
3
RBLT3-768&&-799
4

RBLT3-1632&&-1663
11
RBLT3-384&&-415
12
RBLT3-1056&&-1087
13
RBLT3-2904&&-2935
14
RBLT3-4896&&-4927
15

Check state of the DIP with DTSTP:DIP=11RBL3&&12RBL3;


<dtstp:dip=11rbl2&12rbl2;
DIGITAL PATH STATE
DIP
TYPE STATE LOOP TSLOTL DIPEND FAULT
11RBL3 IEX ABL
LOF
12RBL3 IEX ABL
LOF
END

SECTION

LOF means Loss Of Frame, we have transmission problem in this case

Deblock blocked MO
<rxble:mo=RXOTS-204-9-2;
RXBLE:MO=RXOTS-204-9-2;
<;
RADIO X-CEIVER ADMINISTRATION
MANUAL DEBLOCKING OF MANAGED OBJECT COMMAND RESULT
MO
RXOTS-204-9-2

STATE
PREOP

RESULT
ORDERED

END
<
COMMAND SESSION SUSPENDED
RADIO X-CEIVER ADMINISTRATION
MANUAL DEBLOCKING OF MANAGED OBJECT RESULT
MO
RXOTS-204-9-2

STATE
OPER

RESULT
EXECUTED

END
<rxble:mo=RXOTS-204-9-3;
RXBLE:MO=RXOTS-204-9-3;
<;
RADIO X-CEIVER ADMINISTRATION
MANUAL DEBLOCKING OF MANAGED OBJECT COMMAND RESULT
MO
RXOTS-204-9-3

STATE
PREOP

RESULT
ORDERED

END

Use command RXBLE to deblock the manually blocked MO

Check the TG status again


<rxcdp:mo=rxotg-204;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT CONFIGURATION DATA
MO
RESULT
ARFCN MISMATCH
RXORX-204-0
CONFIG
HOP
NONE
...
RXORX-204-11
CONFIG
HOP
NONE
MO
RXOTS-204-0-0
...
RXOTS-204-9-2
RXOTS-204-9-3
...
RXOTS-204-11-7

RESULT
CONFIG

ARFCN
HOP

TXAD
9

TN
7

BPC
7176

CHCOMB
TCH

CONFIG
CONFIG

203
203

0
0

3
2

1175
1174

TCH
TCH

0
0

NO
NO

ON
ON

CONFIG

HOP

6031

TCH

NO

ON

MO
RXOTX-204-0
RXOTX-204-1
RXOTX-204-2
RXOTX-204-3
RXOTX-204-4
RXOTX-204-5
RXOTX-204-6
RXOTX-204-7
RXOTX-204-8
RXOTX-204-9
RXOTX-204-10
RXOTX-204-11

RESULT
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG

ARFCN
206
HOP
HOP
HOP
200
HOP
HOP
HOP
HOP
HOP
203
HOP

TXAD
2
9
10
11
1
6
7
8
3
4
0
5

MO
RXODP-204-0

RESULT
CONFIG

SBITS

N1
320

MAIO EXCEEDS FREQUENCY SET SIZE


END

BSPWR
45
45
45
45
45
45
45
45
43
43
43
43
N3

OFFS
0

C0F MISMATCH
YES NONE
NO
NONE
NO
NONE
NO
NONE
YES NONE
NO
NONE
NO
NONE
NO
NONE
NO
NONE
NO
NONE
YES NONE
O
NONE
N4

XRA ICM
NO ON

Check cell resources again


<rlcrp:cell=GA4134C;
CELL RESOURCES
CELL
GA4134C

BCCH
1

CBCH
0

SDCCH
8

NOOFTCH
29- 58

...
CHGR
1

BPC
6031

CHANNEL
TCH-1801
TCH-11763
TCH-11762

CHRATE
FR
HR
HR

SPV
1,2,3
1,3
1,3

STATE
BUSY
LOCK
LOCK

ICMBAND
1
1
1

CHBAND
800
800
800

64K
NONE

959

TCH-2529
TCH-13219
TCH-13218
TCH-2530
TCH-13221
TCH-13220

FR
HR
HR
FR
HR
HR

1,2,3
1,3
1,3
1,2,3
1,3
1,3

BLOC
BLOC
BLOC
BUSY
LOCK
LOCK

1
1
1

800
800
800

EGPRS

TCH-275
TCH-8711
TCH-8710

FR
HR
HR

1,2,3
1,3
1,3

IDLE
IDLE
IDLE

1
1
1

800
800
800

NONE

...

960

EGPRS

...
7309
END

We have 29 TCH for FR, it should be 30, something is still wrong. (We have 4
frequencies for the cell, 8 timeslot for each, this means 32 timeslots, but 1 is occupied
by BCCH and an other one by SDCCH, so we have 30 TSs for TCH)

Bring on service the RBLT3


<RXAPP:MO=RXOTG-204;
RADIO X-CEIVER ADMINISTRATION
ABIS PATH STATUS
MO
RXOTG-204
DEV

RBLT3-2926

DCP

APUSAGE

APSTATE

64K

309

UNDEF

IDLE

YES

BRING ON SERVICE

<BLODI:dev=RBLT3-2926;
exdai:dev=RBLT3-2926;
EXDAI:DEV=RBLT3-2926;
<;
EXECUTED
<BLODE:dev=RBLT3-2926;

TEI

Check frequency hopping settings

<rlchp:cell=GA4134C;
CELL CONFIGURATION FREQUENCY HOPPING DATA
CELL
26112B
CHGR HSN HOP
MAIO
BCCD
0
35 OFF DEFAULT
YES
1
35 ON
2
YES
8
14
20
END

<rlcfp:cell=GA4134C;
CELL CONFIGURATION FREQUENCY DATA
CELL
26112B
CHGR SCTYPE SDCCH SDCCHAC TN CBCH
DCHNO
0
1
0
1 NO
35 OFF 93
2
1
1
0
0 NO
35 ON 104
1
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
END

We have 20 hopping frequencies, that's way the maximum for MAIO is 19

HSN HOP

Frequency Hopping types

In baseband hopping each


transmitter is assigned with a fixed
frequency.
At transmission all burst jumping from
one transmitter to the other
independently of the connection
The number of the frequencies can be
used for hopping = The number of
transmitters
Narrow-band combiners can handle
12 (16) transmitters.

In synthesizer hopping one transmitter


handles all frequencies belongs to the
same connection
The number of frequencies can be used
for hopping is independent from the
number of transmitters
Each TRX is configured to hop over a
large amount of frequencies (20 for
example)

Frequency hopping definitions

Random hopping sequence - > pseudo-random sequence

63 independent sequences, parameter HSN specifies which sequence will be used

Length of sequence ~ 6 minutes

Each transceiver in the same channel group in the same cell will be assigned with the same HSN (they
hop in the same way).

Avoid interference -> using an offset in the hopping sequence, called Mobil Allocation Index Offset
(MAIO).

CHGR: a group of frequencies handled in the same way within one cell. Channel group 0 contains the
Broadcast Control Channel (BCCH) and is automatically defined at cell definition.

________________________________
... , f 1 , f 4 , f 4 , f 3 , f 1 , f 2 , f 4 , f 1 , f 3 , f 3 , f 2 , ...
... , f 4 , f 3 , f 1 , f 2 , f 4 , f 1 , f 3 , f 3 , f 2 , f 2 , f 1 , ...
... , f 1 , f 2 , f 4 , f 1 , f 3 , f 3 , f 2 , f 2 , f 1 , f 4 , f 3 , ...
... , f 4 , f 1 , f 3 , f 3 , f 2 , f 2 , f 1 , f 4 , f 3 , f 1 , f 2 , ...

________________________________
Hopping sequences

BCCH: CHGR 0
TCH: CHGR 1 Frequency 104-123
MAIO: A=(0,2,4), B=(6,8,10), C=(12,14,16)
HSN: A=10, B=10, C=10
A valid GSM900 configuration with 20
hopping frequencies

Check MO fault information


rxmfp:mo=rxotg-2,subord,faulty;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION
MO
RXOTF-2

BTSSWVER
ERA-G04-R08-V01

RU RUREVISION
0
RUPOSITION

RUSERIALNO
RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER
00000
EXTERNAL FAULT CODES CLASS 2B
1
END

RXOTF external fault code class 2B means not useable PCM reference (see attached
database)

RBS Software handling

Check loaded software with RXMOP:MOTY=RXOTG;

<rxmop:mo=rxotg-204;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT DATA
MO
RXOTG-21

Download software to DXU with


RXMSC:MO=RXOTG204,SWVER=xxxxx;

Initiate SW change with


RXPLI:MO=RXOTG-204;

RSITE
AHOP COMB FHOP MODEL
MACETOWN_ESB
OFF HYB SY G12

SWVERREPL
B4402R009V
.
END

SWVERDLD

SWVERACT

Summary

RBS: DXU, dTRU, CDU, CXU


Managed objects: TG CF, CON, DP, TF TRXC TX, RX, T

Managed object state: UNDEF, DEF, COM, PREOP (FAIL), OPER (NOOP)

Cell checking, and re-activation:

Check resources: RLCRP


Check connected TG: RXTCP
HALT Cell: RLSTC
Block MO: RXBLI (SUBORD, FORCE)
Take out service: RXESE (SUBORD)
Take in service: RXESI (SUBORD)
Deblock MO: RXBLE (SUBORD)
Activate Cell: RLSTC