You are on page 1of 18

Air Conditioning

Copyright by Hyundai Motor Company. All rights reserved.

Air Conditioning

Specification
Items

PB (i20)

Compressor

Swash plate type (10PA17)

Condenser

Integrated receiver drier

Refrigerant (cc)

57020g

Pressure sensor type

APT

HVAC type

Center mounting type

Cooling fan

Single fan

Cooling fan control

Relay (Low/High)

Fin thermo sensor

Inserted in evaporator

Blower motor
SEMI CTR

Auto 8step (Manual 4steps)

HVAC

AQS sensor not applied


G/BOX

Remarks

CTR MTG
HVAC

G/BOX
(15)

In-car
(5) sensor applied (Motor type), No humidity sensor
FATC

Photo sensor located in the center of crash pad


Water temperature sensor signal is used
Feedback type (position sensor embedded)

TB: SEMI CTR TYPE : G/BOX


capacity
PB: CTR TYPE : G/BOX capacity 15
Diagnosis
by5~6
control panel or scanner

Air Conditioning

Inputs
Block diagram

Tail lamp, Rheostat (illumination)

Fin thermo sensor


In-car sensor
Ambient temperature sensor
Photo sensor

FATC
control

Water temperature sensor


APT

Vehicle speed

Eng. ECM

Switches
Auto, OFF, A/C, Recirculation,
Fresh, Defroster, Defogger, Mode,
Blower speed
Dial switch (temperature)
Power (B+, IG2) and Ground

module

Air Conditioning

Fin thermo sensor


Location & Specification

Temp. ()

Voltage (V)

Temp. ()

Voltage (V)

40

0.94

2.55

30

1.25

2.66

20

1.64

-5

2.94

10

2.12

-10

3.22

Sensor
ground

Sensor
power
(5V)

Air Conditioning

In-car sensor
Location & Specification

Temp. ()

Voltage (V)

Temp. ()

Voltage (V)

60

1.00

3.83

40

1.74

-20

4.52

20

2.78

-40

4.84

In-car sensor
motor (-)

Sensor
ground

Sensor
power (5V)

Air Conditioning

Ambient temperature sensor


Location & Specification
FATC
Ambient
temperature
sensor

Sensor power
(signal)

Trip computer
Sensor power
(signal)
Sensor ground

Air Conditioning

Photo sensor
Location & Specification

Sensor
ground

Sensor
power (5V)

Air Conditioning

Engine temperature sensor


Location & Specification

FATC
ECT
temperature
sensor

ECM, Cluster

Air Conditioning

APT (Automotive pressure transducer)


Location & Specification

A/C Switch
signal (HI)

Blower switch
ON signal

Eng. ECM

A/C
output

APT

Air Conditioning

10

Outputs
Block diagram
FET / Blower motor
Temperature actuator
Mode actuator

FATC
control
module

Intake actuator
Rear defogger
BCM
Rear defogger indicator
Compressor

A/C switch (high)


Blower switch ON

Eng. ECM

Resistor

A/C output
Condenser fan
K-line

Air Conditioning

11

Field Effect Transistor


Location & Specification

Blower
relay
M
D

FET
F/B

FET Gate voltage output

FET Drain voltage


feedback

Air Conditioning
Temperature actuator
Location & Specification

12
Temp. actuator
(Heating)

Sensor
ground
Sensor
power
(5V)
Sensor
f/back

Temp. actuator
Sensor power

5V

HI (32C)

4.55V

LO (17C)

0.45V

Temp. actuator
(Cooling)

Temp.
actuator

Air Conditioning

13

Mode actuator
Location & Specification
Mode actuator
(Defroster)

Sensor
ground
Sensor
power
(5V)

Mode actuator
Sensor power

5V

Vent

0.45V

Bi-level

1.50V

Floor

2.65V

Mix

3.50V

Defroster

4.55V

Mode
actuator
(Vent)

Sensor
f/back

Mode
actuator

Air Conditioning

14

Intake actuator
Location & Specification

A-connector

Recirculation/Fresh
actuator

B-connector

Terminal

Voltage

B-2

Sensor power(5V)

B-11

Sensor feedback

B-6

Sensor ground

A-22

Fresh mode

A-23

Recirculation mode

Air Conditioning

15

Owners setting procedure


Defroster logic control

Cannot be changed !

Temperature unit conversion

OFF button + AUTO button (3sec)

Air Conditioning

16

Diagnosis on the control panel


Procedure

IGN S/W: OFFON

Keep pressing OFF switch and press Mode


switch 4 times within 2sec.

Self-diagnosis
(Continuous check)

Press AUTO

Press AUTO
Proceed to next
step by A/C switch

Press OFF

Self-diagnosis
(Step by step)
Press OFF
FULL AUTO control

Air Conditioning

17

PTC (Positive Temperature Coefficient) Heater

PTC relay 3

PTC relay 2

PTC relay 1

PTC heater

Location of PTC relay 1, 2 and 3

Air Conditioning

18

PTC (Positive Temperature Coefficient) Heater

Condition satisfied

Relay control

PTC
relay 1

PTC
relay 2

Engine
ECM
Heater
Blower motor controller
control

Relay Control

PTC
relay 3

You might also like