The Power & Energy

Applications
industry

Competence in Power & Energy

Flow

Uwe Wagner
Slide 2

Competence in Power & Energy

Steam generator / inside view


Top-view
into the
vessel

Flow
Level
Analysis
Pressure

Evaporato
r pipes

Temperature
Gamma
Recorder

View from
below into
the vessel

Opening for
start up
burner

Discharge opening
for flyash

Competence in Power & Energy

Monitoring the start-up/support


burner
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

To initiate combustion and/or support coal firing of the


boiler, oil is used for the booster and supporting burner
A precise mass measurement installed in the oil flow line
is required for the exact batching and control of the
combustion process

Competence in Power & Energy

Monitoring the start-up/support


burner
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Coriolis mass flow: Promass


Compact device for direct,
precise mass measurement
(kg/h) no additional
instruments required
Replaces mechanical
systems that can obstruct
and block the furnace oil
flow line
No moving parts for
unimpeded flow and
operation of the furnace
(highest available)
Safe measurement, even
with poor quality oil

Competence in Power & Energy

Oil massflow to the start-up


burners in steam generator
Flow
Level
Analysis

Coriolis mass flow meter PROMASS

Advantages of PROMASS in comparison to positive displac

Pressure

Temperature
Gamma
Recorder

References PROMASS

Competence in Power & Energy

Oil massflow to the start-up


burners in steam generator
Flow

Coriolis mass flow meter PROMASS

Level
Analysis
Pressure
Temperature
Gamma
Recorder

Advantages of PROMASS
Direct massflow measurement
in kg/h
No moving parts
High accuracy
High dynamic 1000:1
No inlet- and outlet lengh
necessary
Simple installation (compact)
Devices are available for
temperatures up to 200 C and

Competence in Power & Energy

Positive displacers versus Coriolis flow meters


Flow

Application at the start-up burners of the steam generator

Level
Analysis
Pressure
Temperature
Gamma
Recorder

BEFORE
Positive displacers with a
major effort from the
instrumentation and a
danger of blocking

AFTER
Promass without moving
parts. Direct mass flow
signal and open system
without danger of
blocking

Competence in Power & Energy

Oil massflow to the start-up


burners in steam generator
Flow

Advantages of PROMASS in comparison to positive displa

Level
Analysis
Pressure
Temperature
Gamma
Recorder

Disadvantages of politive
displacers
Accuracy and calibration

depents on constant viscosity


High pressure loss e.g. filter
Conversion of volume to
massflow =>kg/h
Sensitive against dirt; therefore
higher risk of blockage and
danger of breakdown
Moving parts reduce the

Advantages - Promass
Accuracy is independent of oil
characteristics like density and
viscosity
Low pressure loss
Measuring of oil mass flow
direct without conversion
Promass can not blockage,
because the sensor is an open
pipe without built in
No moving parts ensures a high
lifetime and a maintenance-free

Competence in Power & Energy

Oil massflow to the start-up


burners in steam generator
Flow
Level

References
(Heated oil circuit to the different levels of the vessel)

Analysis
Pressure
Temperature
Gamma
Recorder

Oil supply system with various Promass flow meters

Competence in Power & Energy

Reference Power Station La Colette


(England)
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Power station La
Colette in England:
12 pcs. Promass
together with
Siemens Power
Generation

Competence in Power & Energy

Reference Power Station


Braunschweig
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Power Station
Braunschweig/Ger
many:
16 pcs Promass at
the steam
generator

Competence in Power & Energy

Reference Power Station Weiher


Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Power Station
Weiher,
Saarenergie/Ger
many
24 pcs Promass
at differnet levels
at the boiler

Competence in Power & Energy

Reference E.ON Power Station


Wilhelmshaven
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Power Station
Wilhelmshaven,
E.ON:
Promass at
different levels at
the boiler

Competence in Power & Energy

Main cooling water system


Flow

Round
treatment
basin

Level
Analysis
Pressure
Temperature

Air intake in
the lower
part of the
cooling
tower
Kohle-

Gamma
Recorder

lagerpla
tz

140 m high
cooling
towers

Cut view of a
main
condenser

Competence in Power & Energy

Water volumes in the main cooling


water system
Flow

Large volumes of cooling water flow through the main


condenser, helping to create a high degree of efficiency in
the power plant

Level
Analysis

In order to measure cooling water volumes, a measuring


device is required which supplies reliable values even with
Steam from
large pipe diameters
turbine-mean

Pressure

Temperature
Cooling tower
Gamma

Cooling water
circuit

pressure section

Low pressure turbine part

Recorder Drop collector


Trickling
system

Main-condenser

Cooling waterpump
Discharge

Return to the
water/steamcircuit

Competence in Power & Energy

Water volumes in the main cooling


water system
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Ultrasonic flow: Prosonic Flow


Installed directly on pipelines
via detecting sensors with
transmitter mounted
separately
External installation allowing
easy retrofit with no
intrusion into the pipe
Maintenance free with no
moving parts
No obstructions in the
pipeline and no pressure loss
Economical alternative for
large diameters up to 4000
mm

Competence in Power & Energy

Desalination
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

View of a
desalination
plant

Competence in Power & Energy

Volume measurement in
desalination
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Full desalination requires the production of pure water


necessary for the operation of steam boilers
Volumetric flow meters are required for the measuring of
deionized water in the water/steam circuit

Competence in Power & Energy

Volume measurement in
desalination
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Vortex flow: Prowirl


Alternative to dp flow with
orifice plates
Compact device for volume
measurement in deionized
water
Reliable measurement
independent of deionate
conductivity
Large measuring dynamics,
i.e. high turndown
Minimal pressure loss

Competence in Power & Energy

Volume measurement in
desalination
Flow
Level
Analysis
Pressure

Ultrasonic flow: Prosonic Flow


inline
Ideally suited for applications in
process control and utility
measurement in energy
production

Temperature
Gamma
Recorder

Short inlet and outlet length


reducing the space required for
installation in comparison to
orifice plates and Vortex meters
Loop powered transmitter with
accuracy up to 0.3%
Measures the flow of conductive
and especially non-conductive
liquids

Competence in Power & Energy

Control of raw water supply


Flow
Level

Additional water is required as replacement for the


condensate loss in the cooling system and feedwater in
the steam circuit

Analysis
Pressure
Temperature
Gamma
Recorder

The extraction flow rate must be measured in order to


control the chemical cleaning process

Competence in Power & Energy

Control of raw water supply


Flow

Electromagnetic flow:
Promag

Level
Analysis
Pressure
Temperature
Gamma
Recorder

Compact device especially


designed for raw water
usage with sizes from
15mm to 2000mm
Simple commissioning with
user-friendly quick setup via
large display and plain
language text
Relay outputs can be
configured for error
indication, material and
limit value monitoring
Pulse and analog outputs
are fitted as standard and
are freely configurable

Competence in Power & Energy

Level

Uwe Wagner
Slide 24

Competence in Power & Energy

Water-/Steam system
Water-/Steam
system with
pipes and
vessels

Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Steam
turbine
with

Competence in Power & Energy

Steam turbine
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Steam
turbine
Generato
r

Turbinehigh
pressure
section
middle
pressure
section
low pressure
section

Competence in Power & Energy

Innovation of Level in the


Water/Steam system
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Boiler
drum

High
pressure
preheater

Feedwater
tank

Low
pressure
preheater

Main
condenser

Competence in Power & Energy

Innovation of Level in the


Water/Steam system
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Guided radar: Levelflex M


Alternative to displacer/dp
level
Shutdowns avoided due to
independence of vacuum
(hotwell)
Automatic gas phase
compensation for large
measuring errors that can
occur due to high
temperatures and high
pressures (boiler/steam drum)
Independent of density
fluctuations, changing
dielectric numbers, gas
covering steam and vacuum

Competence in Power & Energy

Levelflex vs. traditional dp-level


LEVELFLEX

Flow

Differential pressure

Problem 1: different densities


Problem 2: vacuum

Level

P (bar) = h x x g

Analysis

Gamma
Recorder

Density

P (bar) in
the
container

Solution:
LEVELFLEX shows
the correct level

???
Wrong level indication

Temperature

Direct, exact level measurement

Pressure

1>2

An incorrect and reduced


level is shown, because the
transmitter does not take
the fluctuating densities
caused by changing loads
into account (1 2)

Competence in Power & Energy

Levelflex - THE newcomer in power plants


Flow

Application
Level
Analysis
Pressure
Temperature
Gamma
Recorder

To main
condenser
Levelflex
Bypass pipes
(2 out of 3)

Level measurement of the


condensed steam in front
of the turbine in the main
condenser (Hotwell)
Process: 0.1 bar, max. 40 oC
Measuring range: ca. 2.5 m

Benefits
Measurement with
Levelflex is not influenced
by vacuum => better
solution than differential
More reliable
pressure
measurement
Increased safety

E.ON Power plant Wilhelmshaven

Easier installation

Competence in Power & Energy

Level measurement with radar technology


Flow

Applications in the power plant => example of low


pressure preheater
Measuring technology
Power station Jiangsu Guohua Taichang in China

Level-transmitter (radar
instrument)
LEVELFLEX FMP40

Level
Analysis

Process

Pressure
Temperature

Control the level of the


condensed extraction steam to
protect the steam turbine from
damage.
Medium: Condensate (demiwater)
Operation: 7 bar, 180 oC
Measuring range : 2100 mm

Gamma

Levelflex
FMP40

Recorder

3 bypasses
Features
(2of3 selection)
Signal of
condensate levelLEVELFLEX is installed in a
LP-Preheater

Envelope curve

redundant installation with


three bypasses (2 of 3
selection) to implement the
safety concept of the power
station
The measurement is not
influenced by fluctuations in the
process or fluctuations in
density (pressure, temp.)

Competence in Power & Energy

Level measurement with radar technology


Flow

Application in power plant => example of feedwater


tank
Measuring technology
Level transmitter LEVELFLEX
FMP40

Level

Process

Analysis

Level measurement of
feedwater in the feedwater tank
of water/steam circuit

Pressure
Temperature
Gamma
Recorder

Levelflex
FMP40
3 bypasses
(2of3 selection)
Feedwater
tank

Medium: Feedwater
Operation: app. 10 bar, app. 170
o
C
Measuring range: app. 1600 mm

Features

LEVELFLEX has no moving


parts, therefore no wear and
tear
LEVELFLEX has no mechanical
moving parts, therefore no wear
LEVELFEX is suited for pressure
up to 400 bar or 400 C

SOTEC Waste-to-Energy Power Station TREA Freiburg

Competence in Power & Energy

Level measurement with radar technology


Flow

Application in power plant => example high


pressure preheater
Measuring technology
Power station Anhui Datang Huaibei in China

Level

Process

Analysis
Pressure
Temperature
Gamma
Recorder

Level transmitter LEVELFLEX


FMP45 Installation bypass at
HP Preheater

High Pressure
Preheater
Levelflex
FMP45
Bypass pipe
Envelope curve

Level measurement of the


condensed extraction steam
(auxiliary condensate) in the
High Pressure preheater.
Medium: Condensate (DemiWater)
Operation: 42,4 bar / 300 oC
Measuring range: app. 1100 mm

Features

LEVELFEX is suited very well for


high pressure and temperature
parameters in high pressure
preheaters
Analysis of the signal via the
envelope curve of the
transmitter, that can be viewed
on the display or with a laptop
The measurement is not
influenced by fluctuations in the
process or fluctuations in
density (pressure, temp.)

Competence in Power & Energy

Level measurement with radar technology


Flow

Applications in the power plant => example low


pressure preheater
Measuring technology
Power station Jiangsu Guohua Taichang in China

Level-transmitter (radar
instrument)
LEVELFLEX FMP40

Level
Analysis

Process

Pressure
Temperature

Control the level of the


condensed extraction steam to
protect the steam turbine form
damage.
Medium: Condensate (demiwater)
Operation: 7 bar, 180 oC
Measuring range : 2100 mm

Gamma

Levelflex
FMP40

Recorder

3 bypasses
Features
(2of3 selection)
Signal of
condensate levelLEVELFEX is installed in a
LP-Preheater

Envelope curve

redundant installation with


three bypasses (2 of 3
selection) to implement the
safety concept of the power
station
The measurement is not
influenced by fluctuations in the
process or fluctuations in
density (pressure, temp.)

Competence in Power & Energy

Level measurement with radar technology


Flow

Applications in the power plant => example low


pressure preheater
Measuring technology
Power station Guizhou Qianxi in China

Level
LP-Preheater
Analysis

Level-transmitter (radar
instrument)
LEVELFLEX FMP45

Process

Pressure
Temperature
Gamma

Levelflex
FMP45

Recorder

Redundant
installation

Control the level of the


condensed extraction steam to
protect the steam turbine form
damage
Medium: Condensate (demiwater)
Operation: 1 bar, 170 oC
Measuring range : 600 mm

Features

For safety reasons the


Signal of
condensate level LEVELFEX is installed in a

Envelope curve

redundant installation
The measurement is not
influenced by fluctuations in the
process or fluctuations in
density. (pressure, temp.)
For operating the application
with the envelope curve you can
use the display or the E+H
software TOF-Tool, together
with a laptop

Competence in Power & Energy

Low pressure preheater Today


radar technology
Flow

Measuring technology

Level

level-transmitter (radar
instrument)
LEVELFLEX FMP40/45

Analysis

Process

level measurement of the


condensed extraction steam
(auxiliary condensate) in
preheater (low pressure/high
medium:
pressure)main condenser
operation: max. 4 bar, max. 120
o
C
MB: to ca. 2 m

Pressure
Temperature
Radar device
Gamma
Recorder

Bypass pipe

Features

Pre heater

Old
measurem
ent

RWE power plant Niederaussem

LEVELFEX is suited for pressure


up to 400 bar and 400 degrees
C. This ensures great safety.
the instrument works without
moving parts; no wear.
the measurement is not
influenced by fluctuations in the
process or fluctuations in
density. (pressure, temp.).

Competence in Power & Energy

Level measurement with radar technology


Flow

Applications in the power plant => example low


pressure preheater
Measuring technology
Level-transmitter (radar
instrument)
LEVELFLEX FMP40/45

Level
Analysis

Process

Level measurement of the


condensed extraction steam
(auxiliary condensate) in the
Low Pressure preheater
Medium: condensate (demiwater)
Operation: max. 4 bar, max. 120
o
C
Measuring range : app. 1500 m
Features

Pressure
Temperature
Instrument
Gamma
Recorder

Bypass pipe
LP-Preheater

Old
device

RWE Power Station Niederaussem

LEVELFEX is suited for pressure


up to 400 bar or 400 degrees C.
This ensures great safety
The instrument works without
moving parts; no wear =>
better than replacer
The measurement is not
influenced by fluctuations in the
process or fluctuations in
density. (pressure, temp.)

Competence in Power & Energy

Level measurement with radar technology


Flow

Applications in the power plant => example, main


condenser (2v3 selection)
Measuring technology
Level transmitter LEVELFLEX
installation in the bypass pipe
(2v3 - selection)

Level

Process

Analysis
Pressure
Temperature
Gamma
Recorder

Condenser
(Hotwell)
Levelflex
Bypass pipes
(2of3-choice)

Level measurement of the


condensed steam in front of the
turbine in the main condenser
(Hotwell)
Medium: condensate (demiwater)
Operation: ca. 0,2 bar, max. 40
o
C
Measuring range: app. 2,5 m
Features
Measurement with LEVELFLEX is
not influenced by vacuum; =>
better solution than differential
pressure
Installation is carried out easily
in the bypass

E.ON Power Station Wilhelmshaven

LEVELFLEX has no mechnically


moving parts, therefore no wear

Competence in Power & Energy

Level measurement with radar technology


Flow

Application in power plant => example main


condenser (separate version)
Measuring technology
Level transmitter LEVELFLEX
FMP40 installation as separate
version

Level

Process

Analysis
Pressure
Temperature
Gamma
Recorder

Condenser
(Hotwell)
Levelflex
(remote
electronics)
Bypass pipe

RWE Power plant Wachtberg

Level measurement of the


condensed steam below the
turbine in the main condenser
(Hotwell)
Medium: condensate (demiwater)
Operation: ca. 0,2 bar, max. 40
o
C
Measuring range: app. 2,0 m
Features
The measurement with
LEVELFLEX is not influenced by
vacuum; => better solution
than differential pressure
LEVELFLEX has no moving
parts, therefore no wear
Installation is easy in a bypass
pipe. With the separate version,
interfering vibration is not
passed on to the transmitter

Competence in Power & Energy

Level measurement with radar technology


Flow

Application in power plant => example feedwater


tank
Measuring technology
Level transmitter LEVELFLEX
FMP40

Level

Process

Analysis

Level measurement of
feedwater in the feedwater tank
of water/steam circuit

Pressure
Temperature
Gamma
Recorder

Levelflex
FMP40
3 bypasses
(2of3 selection)
Feedwater
tank

Medium: Feedwater
Operation: app. 10 bar, app. 170
o
C
Measuring range: app. 1600 mm

Features

LEVELFLEX has no moving


parts, therefore no wear
LEVELFLEX has no mechnically
moving parts, therefore no wear
LEVELFEX is suited for pressure
up to 400 bar or 400 degrees C

SOTEC Waste-to-Energy Power Station TREA Freiburg

Competence in Power & Energy

Level measurement in the


ammonia tank
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Guided microwave level:


Levelflex M
Low frequency guided
microwaves are proven to deliver
very reliable measurement in
ammonia tanks
Mounted in the tank or in a
bypass
Independent of density,
temperature or dielectric
constant
Measurement possible with foam
on the surface

Competence in Power & Energy

Level measurement in the


ammonia tank
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Level limit switch: Liquiphant S


Unaffected by flow, turbulence, bubbles,
foam, vibration, solids content or build up
No calibration required: quick, low-cost
startup
No mechanical moving parts: no
maintenance, no wear and tear, long
operation life
Self monitoring of fork for damage
increases plant safety

Competence in Power & Energy

Leakage detection at the


generator
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Because of heat build up, generators in a power plant must be


cooled. This is usually done with hydrogen cooling gas.
Discharge lines are located at the generator housing. If
lubricants reach the housing due to leakage in the thrust
bearings, the rise in liquid is detected by the Liquiphant limit
switch at the end of the discharge lines. The problem is then
recognized and can be eliminated.

Competence in Power & Energy

Leakage detection at the


generator
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Level limit detection:


Liquiphant
Compact instrument for level
limit detection in liquids using the
vibration principle
Ideal solution for applications
where space is limited
Leakage detection to protect
generator and protects pump
against running dry
Ex version for use in hazardous
areas where hydrogen may be
present
Maintenance free no moving
parts

Competence in Power & Energy

Pressure

Uwe Wagner
Slide 45

Competence in Power & Energy

References: Coal power


stations
Flow

Power Station Voerde

Level
Analysis
Pressure

Power Station Bergkamen

Temperature
Gamma

Power Station Herne

Recorder

Power Station Lnen

Competence in Power & Energy

Differential Pressure in the


Water/Steam system
Flow
Level
Analysis
Pressure
Temperature
Gamma
Recorder

Deltabar S
Very good
reproducibility and longterm stability
Used for flow, level and
differential pressure
monitoring to SIL2
Flow measurement
together with orifice
plates, pitot tubes and
other primary elements
Function-monitored
from the measuring cell
to the electronics Installation via impulse pipes (2oo3)