You are on page 1of 70

Network Interference Investigation

Classification of Interference sources in network

R99 Power Control

HSDPA Power Control

HSUPA Power Control

R99 Power Control

Uplink Open Loop Power Control of R99

Downlink Open Loop Power Control of R99

Uplink Inner Loop Power Control of R99

Downlink Inner Loop Power Control Of R99

Uplink Outer Loop Power Control of R99

Downlink Power Balancing of R99

UL Open Loop Power Control of R99 Common


Channel (PRACH)
The transmission power of the first preamble :
Preamble_Initial_Power Primary CPICH DL TX power CPICH_RSCP UL interference Constant Value

Where
1. Primary CPICH DL TX power
(PcpichPwr) the transmission
power of the P-CPICH
2. CPICH_RSCP measured by UE
3. UL interference measured and
obtained by NodeB and updated in
real time in SIB7
4. Constant Value (ConstVal) a
value related with the cell
environment. It is a value depends on
the service rate and quality carried
by PRACH.

UL Open Loop Power Control of R99


Common Channel (PRACH)
The transmission power of the PRACH control part :

PRACH_C_Power Preamble_Initial_Power Power Ramp Step P p-m


Where,
1 Power Ramp Step (PRStep) the power offset between two continuous
preambles.
2 Pp_m (POPpm[MAX_ PRACH _TFC]) the power offset between the control
channel and the last preamble of the message part.
The transmission power of the PRACH data part :

BetaC[MAX_ PRACH
_TFC]

(BetaD[MAX_ PRACH _TFC])

UL Open Loop Power Control of R99 Dedicated


Channel (DPCCH/DPDCH)
DPCCH Initial Power

DPCCH _ Initial _ power DPCCH _ Power _ offset CPICH _ RSCP


Where
1 DPCCH_Power_offset determined by DPCCH open loop power control
method.
2 CPICH_RSCP the CPICH channel code power
DPCCH _ Power _ Offset Eb / N 0 (dB ) ( N T I T )(dBm) PG (dB) CPICH _ TX _ Power

Where
Eb/No: quality factor of the DPCCH PILOT domain (DpcchPilotEbN0).
NT+IT uplink interference,
PG service processing gain, 256.
CPICH_TX_Power (PcpichPwr) transmission power of the P-CPICH.

UL Open Loop Power Control of R99 Dedicated


Channel (DPCCH/DPDCH)
Determining the gain factor c and d
1 For single service
c and d are configured directly according to different service rates and different
TFC. It is usually required that either c or d must be 15.
For example: UL PS64k streaming/interactive/background Service
c

TFC Format

0336, 0144

15

1336, 0144

15

14

2336, 0144

11

15

4336, 0144

15

0336, 1144

15

1336, 1144

14

15

2336, 1144

10

15

4336, 1144

15

2 For multiple service


c and d are calculated by RNC according to reference TFC.

Downlink Open Loop Power Control of R99 Common


Channel

P-CPICH power is configured depends on the proportion of maximum transmission


power of the cell.
Other downlink common channel power is configured as a power offset of P-CPICH
power.

Channel

Power Parameter

Default Value

P-CPICH

PcpichPwr

33dBm

P-SCH

PschPwr

-3dB

S-SCH

SschPwr

-4dB

AICH

AichPwr

-7dB

PICH

PichPwr

-7dB

P-CCPCH (BCH )

BchPwr

-3dB

S-CCPCH bears the transport channel of PCH and FACH, and the number
of FACH channels is variable, the transmission power (PchPwr) of each
PCH and the maximum transmission power (MaxFachPwr) allowed for each
FACH beared by a certain S-CCPCH is specified in related protocol.

Downlink Open Loop Power Control of R99 Dedicated


Channel

Initial power of DL DPCH data domain is calculate based on


CPICH Ec/N0
Eb
Ptx ,init

N 0
PG

req

Ptx ,CPICH
max min

min
Ptx ,total
L k1
E c cpich

k2
1

10

N0

The power of control domain (TPC/CFTI/Pilot) is power offset


relative to the power of data domain.

DL DPCH TFCI :PO1 (DpchPO1),


DL DPCH TPC :PO2 (DpchPO2) ;
DL DPCH PIOLT :PO3(DpchPO3)

The maximum and minimum values of DPCH power is


MaxDlDpchPwr and MinDlDpchPwr.

Uplink Inner Loop Power Control of R99

UlIlPcAlg =1 , the transmission power can be


adjusted in every timeslot.

Suppose the TPCs of all radio link sets are 1, then TPC_cmd=1 (to
increase transmission power).
Suppose one TPC coming from any radio link set is 0, then

TPC_cmd=-1 (TPC being 0 indicates the transmission power should


be decreased).

UlIlPcAlg =2, the transmission power is adjusted


once every five timeslots.

Downlink Inner Loop Power Control Of R99

Downlink DPCH power is P(k) = P(k - 1) + PTPC(k) + Pbal(k) ,

where

if TPC est (k ) 1 and sum (k ) TPC Power_Raise_Limit

1)

if TPC est (k ) 1 and sum (k ) TPC Power_Raise_Limit

TPC

PTPC ( k )
0

TPC

sum (k )

TPC

k 1

if TPC est (k ) 0

(i )

TPC
i k DL_Power_Averaging_Window_Size

is the power adjustment step (TpcDlStep), and


Power_Raise_Limit is PwrRaisLim.
Two power control modes (DPCMode) are also available to determine
PTPC(k):

DPCMode = 0, UE sends a TPC command at each timeslot.

DPCMode = 1, UE sends the same TPC command for three timeslots.


(ZTE RNC not support now)

2) Pbal(k) is a correction value obtained according to the downlink power


control process.

Uplink Outer Loop Power Control of R99

As to DCH service Using Threshold Algorithm Based on


CRC to modify SIRtarget in time:

In a valid time window (ValidTimeWin), sum all the transport block


that have received as BLOCK_SUM, and sum all the error blocks
as BLOCKerror_SUM.
Increase SIRtarget immediately as soon as BLOCKerror_SUM is
higher than the error transport block number threshold
(ErrorThresh) while BLOCK_SUM is no more than a predefined
number (BLERAccpPeriod) ;
Decrease SIRtarget only when BLOCK_SUM is no less than the
BLERAccpPeriod and the BLOCKerror_SUM is less than the
ErrorThresh,
Normally, the increased step (UlSirTargUpStep) is bigger than
decreased step (UlSirTargDnStep) .

The initial SIR target is ULInitSIR;


The maximum SIR target is ULMaxSIR;
The minimum SIR target is ULMinSIR;

Downlink Power Balancing of R99

A simple formula for calculating Pbal is as follows:

bal

(1 r )( Pref PP CPICH Pinit ) precision 0.5dB

Where,
Pref is a reference power, which equals to DL Reference Power.
N

DL _ Re fer _ Power

DL _ Re fer _ Power

j 1

DL _ Re fer _ Power ( dB) j PDPDCH P _ CPICH _ Power

PDPDCH (dBm) TCP PO3

Pinit is the code power of the last timeslot in the previous adjustment
period.
r is the adjustment convergence coefficient (AdjRatio) that ranges 0~1.

DpchPO1
Parameter name

DPCH PO1

Abbreviated name

DpchPO1

3GPP name

PO1

3GPP reference

TS 25.423;TS 25.433

Description

This parameter indicates the power offset between


the DL DPCH TFCI domain and the DPCH data
domain.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(0..6) dB step 0.25 dB

Default value

(Service related)

DpchPO2
Parameter name

DPCH PO2

Abbreviated name

DpchPO2

3GPP name

PO2

3GPP reference

TS 25.423;TS 25.433

Description

This parameter indicates the power offset between


the DL DPCH TPC domain and the DPCH data
domain.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(0..6) dB step 0.25 dB

Default value

(Service related)

DpchPO3
Parameter name

DPCH PO3

Abbreviated name

DpchPO3

3GPP name

PO3

3GPP reference

TS 25.423;TS 25.433

Description

This parameter indicates the power offset between


the DL DPCH PILOT domain and the DPCH data
domain.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(0..6) dB step 0.25 dB

Default value

(Service related)

UlIlPcAlg
Parameter name

Uplink Inner Loop Power Control Algorithm

Abbreviated name

UlIlPcAlg

3GPP name

Power Control Algorithm

3GPP reference

TS 25.331

Description

This parameter indicates which uplink inner loop


power control algorithm is used. For algorithm 1
inner loop power control is done every timeslot. For
algorithm 2 inner loop power control is done every 5
timeslots.

Working scope

UTRAN Cell and Service Related

Value range

1: Algorithm 1
2: Algorithm 2

Default value

Algorithm 1

TpcStepSize
Parameter name

TPC Step Size

Abbreviated name

TpcStepSize

3GPP name

TPC step size

3GPP reference

TS 25.331

Description

This parameter indicates the TPC step size for


uplink inner loop power control. Only when inner
loop power control algorithm 1 is selected, this
parameter needs to be configured. For algorithm 2,
default value of TPC step size is 1 and this
parameter is not needed.

Working scope

UTRAN Cell and Service Related

Value range

(1,2)dB

Default value

1dB

DPCMode
Parameter name

DPC Mode

Abbreviated name

DPCMode

3GPP name

DPC Mode

3GPP reference

TS 25.433; TS 25.423

Description

This parameter indicates which downlink inner loop


power control algorithm is used. There are two
DPC
Mode inner power control algorithm:
kinds of
downlink
single TPC and TPC triplet in soft. And which
algorithm to be used should be configured to UE.

Working scope

UTRAN Cell

Value range

0: Single TPC
1: TPC Triplet in Soft

Default value

single TPC

TpcDlStep
Parameter name

TPC DL Step Size

Abbreviated name

TpcDlStep

3GPP name

FDD TPC Downlink Step Size;

3GPP reference

TS 25.433; TS 25.423

Description

This parameter indicates the step size fo the


downlink inner loop power control. Normally, the
DPC
Mode
value in
good
channel condition is smaller than in
bad channel condition.

Working scope

UTRAN Cell and Service Related

Value range

(0.5, 1, 1.5, 2)dB

Default value

1dB

MaxDlDpchPwr
Parameter name

DPCH Maximum DL Power

Abbreviated name

MaxDlDpchPwr

3GPP name

Maximum DL Power; Maximum DL TX Power

3GPP reference

TS 25.423; TS 25.433

Description

This parameter indicates the maximum downlink


DPCH transmission power. When performing the
downlink inner loop power control, the new
transmission power must be smaller than or equal
to the configured DPCH Maximum DL Power. If the
newly computed transmission power is larger than
the configured DPCH Maximum DL Power, make it
equal to the configured DPCH Maximum DL Power.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-35..15 ) dB step 0.1 dB

Default value

(Service related)

MinDlDpchPwr
Parameter name

DPCH Minimum DL Power

Abbreviated name

MinDlDpchPwr

3GPP name

Minimum DL Power

3GPP reference

TS 25.423; TS 25.433

Description

This parameter indicates the minimum downlink


DPCH transmission power. When performing the
downlink inner loop power control, the new
transmission power must be larger than or equal to
the configured DPCH Minimum DL Power. if the
newly computed transmission power is smaller than
the configured DPCH Minimum DL Power, make it
equal to the configured DPCH Minimum DL power.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-35..15) dB step 0.1 dB

Default value

(Service related)

MaxUlDpchPwr

Parameter name

Maximum Allowed Uplink DPCH Transmission Power

Abbreviated name

MaxUlDpchPwr

3GPP name

Maximum allowed UL TX power; Maximum Allowed UL


Tx Power

3GPP reference

TS 25.423; TS 25.331

Description

This parameter indicates the maximum allowed UL


power used to limit the maximum transmission power of
the UE. When performing the uplink inner loop power
control, the newly calculated transmission power of UE
may be over the Maximum allowed UL TX power, in
such case the UE can only transmit with Maximum
allowed UL TX power.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

-50..33 dBm step 1

Default value

33dBm

UlSirTargUpStep
Parameter name

Uplink SIR Target Up Step Size

Abbreviated name

UlSirTargUpStep

3GPP name

3GPP reference

Description

This parameter indicates the step of increasing the


uplink SIR target.

Working scope

UTRAN Cell and Service Related

Value range

(0.1..0.5)dB step 0.1dB

Default value

UL PS 384kbps: 0.5dB
Other services: 0.3dB

UlSirTargDnStep
Parameter name

Uplink SIR Target Down Step Size

Abbreviated name

UlSirTargDnStep

3GPP name

3GPP reference

Description

This parameter indicates the step of decreasing the


uplink SIR target.

Working scope

UTRAN Cell and Service Related

Value range

(0.1..0.5)dB step 0.1dB

Default value

0.1dB

ULInitSIR
Parameter name

Uplink Initial SIR Target

Abbreviated name

ULInitSIR

3GPP name

UL SIR Target

3GPP reference

TS 25.423; TS 25.433

Description

This parameter indicates the initial SIR target of the


uplink physical channel. The target SIR is the
standard to perform the uplink inner loop power
control. The value has effect on the convergence
speed of the power control.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

-8.2..17.3 dB step 0.1 dB

Default value

(Service related)

ULMaxSIR
Parameter name

Maximum Uplink SIR Target

Abbreviated name

ULMaxSIR

3GPP name

Maximum Uplink SIR

3GPP reference

TS 25.423; TS 25.433

Description

This parameter indicates the maximum uplink


target SIR, which is used to give the range for the
target SIR of the outer loop power control.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

-8.2..17.3 dB step 0.1 dB

Default value

(Service related)

ULMinSIR
Parameter name

Minimum Uplink SIR Target

Abbreviated name

ULMinSIR

3GPP name

Minimum Uplink SIR

3GPP reference

TS 25.423

Description

This parameter indicates the minimum uplink target


SIR, which is used to give the range for the target
SIR of the outer loop power control.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

-8.2..17.3 dB step 0.1 dB

Default value

(Service related)

Technical Description

R99 Power Control

HSDPA Power Control

HSUPA Power Control

MBMS Power Control

HSDPA Power Control


Power Offsets of HS-DPCCH-related
Domains
HS-PDSCH Measurement Power Offset
Total Power Allocation of HSDPA

Power Offsets of HS-DPCCH-related Domains

HS-DPCCH carries the ACK, NACK and CQI information, Its


power control is same with UL DPCCH power control, except
that the power gain factor hs is different.
In normal mode, hs is calculated by UE according to ACK,
ACK and CQI using the following formula:

hs c 10

HS DPCCH

20

Where:
c is the power gain factor of UL DPCCH.
When HS-DPCCH is activated, each slot of HS-DPCCH, HS-DPCCH is set
with the following methods:
i) When HS-DPCCH carries the HARQ ACK information: If ACK = 1, then
HS-DPCCH = ACK; if ACK = 0, then HS-DPCCH = NACK.
ii) When HS-DPCCH carries the CQI information: HS-DPCCH = CQI.

HS-PDSCH Measurement Power Offset

When measuring CQI, UE supposes the power of HSPDSCH is:

PHSPDSCH PCPICH
Where,

is the measurement power offset (MeasPwrOffset);

is obtained by UE through querying the table depending on


the UE category.

Total Power Allocation of HSDPA

There are three HSDPA total power allocation methods. The


system determines which allocation method applies according
to the parameter HsdschTotPwrMeth configured in OMCR.

Total Power Allocation of HSDPA


Total Power Allocation of HSDPAStatic allocation by RNC
Configure the percentage of power occupied by HSDPA: HspaPwrRatio in OMCR.

Total Power Allocation of HSDPADynamic allocation by RNC


i)

Initial HS-PDSCH and HSSCCH total power


(HspaPwrRatio) is configured
in OMCR
ii) During the system operation,
the HS-PDSCH and HSSCCH total power
dynamically adjusted
according to condition
described is right figure.

Total Power Allocation of HSDPA


Total Power Allocation of HSDPAFree allocation of NodeB
Free power allocation is determined by algorithm of NodeB based on
available power, service priority and CQI.

AckPwrOffset
Parameter name

HS-DPCCH ACK Power Offset for Single Radio


Link or Intra-NodeB Handover

Abbreviated name

AckPwrOffset

3GPP name

ACK Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH ACK domain relative to DPCCH when UE
has a single link or is in the intra-NodeB handover.

Working scope

RNC

Value range

0..9

Default value

NackPwrOffset
Parameter name

HS-DPCCH NACK Power Offset for Single Radio


Link or Intra-NodeB Handover

Abbreviated name

NackPwrOffset

3GPP name

NACK Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH NACK domain relative to DPCCH when
UE has a single link or is in the intra- NodeB
handover.

Working scope

RNC

Value range

0..9

Default value

CqiPwrOffset
Parameter name

HS-DPCCH CQI Power Offset for Single Radio Link


or Intra-NodeB Handover

Abbreviated name

CqiPwrOffset

3GPP name

CQI Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH CQI domain relative to DPCCH when UE
has a single link or is in the intra-NodeB handover.

Working scope

RNC

Value range

0..9

Default value

InterAckPwrOfst
Parameter name

HS-DPCCH ACK Power Offset for Inter-NodeB


Handover

Abbreviated name

InterAckPwrOfst

3GPP name

ACK Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH ACK domain relative to DPCCH when UE
is in inter-Node B handover.

Working scope

RNC

Value range

0..9

Default value

InterNackPwrOfst
Parameter name

HS-DPCCH NACK Power Offset for Inter-NodeB


Handover

Abbreviated name

InterNackPwrOfst

3GPP name

NACK Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH NACK domain relative to DPCCH when
UE is in inter-Node B handover.

Working scope

RNC

Value range

0..9

Default value

InterCqiPwrOfst
Parameter name

HS-DPCCH CQI Power Offset for Inter-NodeB


Handover

Abbreviated name

InterCqiPwrOfst

3GPP name

CQI Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the power offset of HSDPCCH CQI domain relative to DPCCH when UE
is in inter-NodeB handover.

Working scope

RNC

Value range

0..9

Default value

CqiCycle
Parameter name

CQI Feedback Cycle

Abbreviated name

CqiCycle

3GPP name

CQI Feedback Cycle

3GPP reference

TS 25.433

Description

This parameter indicates the CQI feedback cycle,


to determine the time to send CQI. When the value
is 0, the UE does not feed back the channel quality.

Working scope

RNC

Value range

(0, 2, 4, 8, 10, 20, 40, 80, 160) ms

Default value

2ms

CqiRepFactor
Parameter name

CQI Repetition Factor

Abbreviated name

CqiRepFactor

3GPP name

CQI Repetition Factor

3GPP reference

TS 25.433

Description

This parameter indicates the CQI repetition factor,


indicating the number of consecutive repetitions of
the CQI.

Working scope

RNC

Value range

1..4

Default value

AnackRepFactor
Parameter name

ACK-NACK Repetition Factor

Abbreviated name

AnackRepFactor

3GPP name

ACK-NACK Repetition Factor

3GPP reference

TS 25.433

Description

This parameter indicates the ACK-NACK repetition


factor, indicating the number of consecutive
repetitions of the ACK and NACK.

Working scope

RNC

Value range

1..4

Default value

HsscchPwrOffset
Parameter name

HS-SCCH Power Offset

Abbreviated name

HsscchPwrOffset

3GPP name

HS-SCCH Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the HS-SCCH power


offset, which is relative to the power of downlink
DPCH pilot bits.

Working scope

Service Related

Value range

(-32..+31.75) dB step 0.25

Default value

HspaPwrRatio
Parameter name

HSPA Total Downlink Power

Abbreviated name

HspaPwrRatio

3GPP name

HS-PDSCH, HS-SCCH,E-AGCH, E-RGCH and EHICH Total Power

3GPP reference

TS 25.433

Description

The parameter indicates the initial value of the total


transmission power of HS-PDSCH, HS-SCCH, EAGCH, E-RGCH and E-HICH codes, which is a
ratio relative to the maximum DL transmission
power of the cell.

Working scope

UTRAN Cell

Value range

(1..100) % step 1%

Default value

40

MeasPwrOffset
Parameter name

HS-PDSCH Measurement Power Offset

Abbreviated name

MeasPwrOffset

3GPP name

Measurement Power Offset

3GPP reference

TS 25.433

Description

This parameter indicates the assumed HS-PDSCH


power offset relative to P-CPICH/S-CPICH power
used for CQI measurement.

Working scope

UTRAN Cell

Value range

(-6..13)dB step 0.5 dB

Default value

Technical Description

R99 Power Control

HSDPA Power Control

HSUPA Power Control

HSUPA Power Control

Uplink E-DPCCH/DPCCH Power Offset

Uplink E-DPDCH/DPCCH Power Offset

Downlink E-AGCH/RGCH/HICH Power

HSUPA Uplink Outer Loop Power Control

Uplink E-DPCCH/DPCCH Power Offset


The uplink E-DPCCH open loop power control of HSUPA is realized by setting a
reasonable E-DPCCH power offset relative to that of DPCCH.
According to 25.214 standard, the gain factor ec of E-DPCCH is calculated using the
following formula in non-compressed mode:

ec c Aec
Where,
c is the gain factor of uplink
dedicated control physical channel of
R99.
Aec is obtained from E-DPCCH
power offset (E-DPCCH) that is
configured at high level and then
mapped in the right table .

Signalled values for


E-DPCCH

Quantized amplitude ratios


Aec = ec/ c

30/15

24/15

19/15

15/15

12/15

9/15

8/15

6/15

5/15

Uplink E-DPDCH/DPCCH Power Offset


Reference E-TFC and ed,ref
The 3GPP specifies that RNC notifies UE and NodeB of a group of reference ETFC and the corresponding E-DPDCH power offset relative to DPCCH, to be used by
UE and NodeB to calculate the power needed by other non-reference E-TFC.
ed,ref is the reference gain factor of the reference E-TFC, and for each reference ETFC, the ed,ref can be calculated using the following formula:

ed ,ref c Aed
Where,
c is the gain factor of uplink
dedicated control physical channel of
R99.
Aed is obtained from E-DPCCH
power offset (E-DPCCH) that is
configured at high level and then
mapped in the right table .

Signalled values for


E-DPDCH

Quantified amplitude ratios


Aed

29

168/15

28

150/15

27

134/15

..

6/15

5/15

Uplink E-DPDCH/DPCCH Power Offset


ed
The gain factor of E-DPDCH is defined as ed, which can be of a different value for each
E-TFC and HARQ offset.
For the number jth E-TFC, the gain factor ed,j,harq of the related E-DPDCH can
be calculated using the following formula

ed , j ,harq ed , ref

Le,ref

Ke, j

Le, j

K e ,ref

10

harq

20

Where,
Le,ref : the number of E-DPDCHs used by reference E-TFC.
Le,j : the number of E-DPDCHs used by the number jth E-TFC.
Ke,ref : the number of data bits of reference E-TFC.
Ke,j : the number of data bits of the number jth E-TFC.
harq: HARQ power offset (EdchHarqPOFdd);

Downlink E-AGCH/RGCH/HICH Power


For E-AGCH, E-RGCH and E-HICH, the power is in the form of power offset.
E-AGCH power offset (EagchPOTti2 or EagchPOTti10, depending on different TTIs)
E-RGCH power offset (ErgchPOTti2 or ErgchPOTti10, depending on different TTIs)
E-HICH power offset (EhichPOTti2 or EhichPOTti10, depending on different TTIs)

When F-DPCH is configured, the power offset is relative to F-DPCH TPC domain.
When F-DPCH is configured, the power offset is relative to F-DPCH TPC domain.

Update:
The configuration of the power offsets in OMCR are related with different services.
When the control plane detects changes (establishment, addition, deletion and
modification) in the sub-services carried by DPCH, the new power offset is obtained
from the database according to the number of sub-service and then configured again.
When TTIs change, the power offsets are configured again.
In the macro diversity status, the power offset is updated. For a multi-link case, EAGCH power offset takes the value of E-AGCH Power Offset + Macro Diversity Gain.

HSUPA Uplink Outer Loop Power Control


Reflect service quality:
HARQ failure
Number of HARQ Retransmission (NHR)
In fact, when HARQ failure happen, it can be converted to a certain NHR
according to the maximum retransmission :
NHR = CorrNumHarqToNhr * MaxRetransEdch
Where,
CorrNumHarqToNhr is correction coefficient for converting HARQ failure to
NHR;
MaxRetransEdch is the maximum number of retransmissions for E-DCH.

To better reflect the channel quality, the average NHR value during a statistical
period is usually taken as the basis for decision. The average NHR during a
statistical period is defined as:
I

Num Re TransDiffAve NHRi / I


i 1

HSUPA Uplink Outer Loop Power Control

Update method:

i)

If NumReTransDiffAve > NhrThrUp, increase SIRtarget


by one adjustment step;

ii) If NumReTransDiffAve < NhrThrUp, decrease SIRtarget


by one adjustment step.

HSUPA Uplink Outer Loop Power Control

SIRtarget adjustment in the case of concurrent services:


i) SIRtarget is increased as long as one service triggers it to be increased.
ii) SIRtarget is not decreased unless all services with valid NHR statistics
indicate to decrease SIRtarget. Services with invalid NHR statistics are
excluded from the combination of power control.
iii) Some services need to decrease SIRtarget while some others need SIRtarget
to remain the same, In this way, SIRtarget is not adjusted to guarantee QoS of
all services.

HSUPA Uplink Outer Loop Power Control


Coupling implementation of HSUPA and R99 outer loop power control
As the outer loop power control
event algorithm of E-DCH
introduced, it may affect the
current outer loop power control
algorithm in some cases. In this
case, a final decision described
in right table should be made by
RNC.
In the right table:
indicates increase,
for decrease,
- for no adjustment (remain
unchanged),
for invalid NHR statistics.

E-DCH

DCH

State

Combination Result

10

11

12

13

14

15

16

(invalid NHR statistics, no


adjustment)

EdpcchPOTti2
Parameter name

Quantified E-DPCCH/DPCCH Power Offset 2ms


TTI

Abbreviated name

EdpcchPOTti2

3GPP name

E-DPCCH/DPCCH power offset; E-DPCCH Power


Offset

3GPP reference

TS 25.331 25.423 25.433

Description

This parameter indicates the quantified EDPCCH/DPCCH power offset configured to 2ms EDCH transmission time interval.

Working scope

RNC

Value range

0..8

Default value

EdpcchPOTti10
Parameter name

Quantified E-DPCCH/DPCCH Power Offset (10ms


TTI)

Abbreviated name

EdpcchPOTti10

3GPP name

E-DPCCH/DPCCH power offset; E-DPCCH Power


Offset

3GPP reference

TS 25.331 25.423 25.433

Description

This parameter indicates the quantified EDPCCH/DPCCH power offset configured to 10ms
E-DCH transmission time interval.

Working scope

RNC

Value range

0..8

Default value

ScheInfoPOTti2
Parameter name

Power Offset for Scheduling Info (2ms TTI)

Abbreviated name

ScheInfoPOTti2

3GPP name

E-DCH Power Offset for Scheduling Info; Power


Offset for Scheduling Info

3GPP reference

TS 25.331 25.433

Description

This parameter indicates the power offset for


scheduling information configured to 2ms E-TTI.
When no MACd PDUs are included in the same
MACe PDU, UE will use power offset for scheduling
information as HARQ power offset to compute the
transmission power of E-DPDCH.

Working scope

RNC

Value range

0..6

Default value

ScheInfoPOTti10
Parameter name

Power Offset for Scheduling Info (10ms TTI)

Abbreviated name

ScheInfoPOTti10

3GPP name

E-DCH Power Offset for Scheduling Info; Power


Offset for Scheduling Info

3GPP reference

TS 25.331 25.433

Description

This parameter indicates the power offset for


scheduling information configured to 10ms E-TTI.
When no MACd PDUs are included in the same
MACe PDU, UE will use power offset for scheduling
information as HARQ power offset to compute the
transmission power of E-DPDCH.

Working scope

RNC

Value range

0..6

Default value

EagchPOTti2
Parameter name

E-AGCH Power Offset for TTI 2ms

Abbreviated name

EagchPOTti2

3GPP name

E-AGCH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-AGCH in
2ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-2dB

EagchPOTti10
Parameter name

E-AGCH Power Offset for TTI 10ms

Abbreviated name

EagchPOTti10

3GPP name

E-AGCH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-AGCH in
10ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-9dB

ErgchPOTti2
Parameter name

E-RGCH Power Offset for TTI 2ms

Abbreviated name

ErgchPOTti2

3GPP name

E-RGCH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-RGCH in
2ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-3dB

ErgchPOTti10
Parameter name

E-RGCH Power Offset for TTI 10ms

Abbreviated name

ErgchPOTti10

3GPP name

E-RGCH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-RGCH in
10ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-9dB

EhichPOTti2
Parameter name

E-HICH Power Offset for TTI 2ms

Abbreviated name

EhichPOTti2

3GPP name

E-HICH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-HICH in
2ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-3dB

EhichPOTti10
Parameter name

E-HICH Power Offset for TTI 10ms

Abbreviated name

EhichPOTti10

3GPP name

E-HICH Power Offset

3GPP reference

TS 25.423 25.433

Description

This parameter indicates the power offset relative


to DL DPCH pilot domain configured for E-HICH in
10ms E-TTI.

Working scope

UTRAN Cell, Service and Diversity Mode Related

Value range

(-32 .. +31.75)dB step 0.25 dB

Default value

-9dB

NhrThrUp
Parameter name

NHR Threshold to Adjust SIR Target Upward

Abbreviated name

NhrThrUp

3GPP name

3GPP reference

Description

This parameter indicates the number of HARQ


retransmission (NHR) threshold to increase SIR
target. When the NHR exceeds the threshold, RNC
shall increase the SIR target. It is only applicable
for the services carried on E-DCH.

Working scope

Service Related

Value range

(0..15) step 0.01

Default value

10ms E-TTI
2ms E-TTI

0.03
0.3

NhrThrDown
Parameter name

NHR Threshold to Adjust SIR Target Downward

Abbreviated name

NhrThrDown

3GPP name

3GPP reference

Description

This parameter indicates the number of HARQ


retransmission (NHR) threshold to decrease SIR
target. When the NHR is less than the threshold,
RNC shall decrease the SIR target. It is only
applicable for the services carried on E-DCH.

Working scope

Service Related

Value range

(0..15) step 0.01

Default value

10ms E-TTI 0.01


2ms E-TTI 0.1