You are on page 1of 18

UEBHERR

AfterSales Service International Service Information


Service information no. 02/2006 LHG/TKD-Ne/09.02.06

Appliance Documentation

CN(es) 3303 / 3803 from Index 21


Model: 001, 003, 088, 210

NoFrost combined refrigerator-freezers

02200600SI_gb.doc
Service Information No. 02/2006 (Version 01) CN(es) ..03

Contents

1.0 Operating and control elements3


2.0 Functions at a glance3
3.0 Description of the appliance4
3.1 Refrigerator compartment: 4
3.2 NoFrost freezer compartment 4
3.3 Refrigerating circuit 5
4.0 Control and functional components6
4.1 Refrigerator compartment 6
4.2 NoFrost freezer compartment 7
5.0 Refrigeration circuit8
5.1 Refrigerator compartment 8
5.2 NoFrost freezer compartment 8
6.0 Special features9
6.1 Solenoid valve 9
6.1.1 Electrical actuation of the solenoid valve 9
6.1.2 Schematic diagrams solenoid valve 9
7.0 Assembly instructions9
7.1 Refrigerator compartment 9
7.1.1 Evaporator sensor 9
7.1.2 CN(es) 3303 / 3803 from -21 fan 10
7.2 NoFrost freezer compartment 11
7.2.1 Air sensor, evaporator module and fan module 11
7.2.2 Temperature fuse, evaporator sensor and defrosting heater 12
7.2.3 Fan and reed PCB 12
7.2.4 Water drain valve 13
7.3 Solenoid valve 13
7.4 Integral PCB 14
8.0 Technical data16
8.1 Refrigerator compartment 16
8.2 NoFrost freezer compartment 16
9.0 Service menu17
9.1 NoFrost freezer compartment defrosting "-15C LED" (evaporator must be cold) 17
9.2 Demo mode 17
9.3 Service mode 18
10.0 Table of error codes18

Page 2 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

1.0 Operating and control elements

0> (2> (s

Refrigerator Freezer compartment


compartment 1 : Control button, 2 : Alarm OFF button for audible alarm
ON / OFF, temperature setting. button lit = active alarm for too high
3 : Temperature setting display temperature in freezer compartment.
refrigerator compartment 4 : Temperature setting display
freezer
compartment
5 : SuperFrost button,
button lit = function switched on.
6 : Control button,
ON / OFF for the entire appliance
(refrigerator and freezer
compartment), temperature setting.

2.0 Functions at a glance


Control: Electronic control system

Temperature display: Set value display


Refrigerator
no
Temperature alarm: compartment: Freezer
visual and audible
compartment:
Door alarm: Refrigerator
audible
compartment: Freezer
audible
compartment:
Fan: Refrigerator
compartment: no
CN(es) 3303 / 3803 from -20
Refrigerator yes
CN(es) 3303 / 3803 from -21
compartment: Freezer yes
compartment:
Refrigerator
automatic
Defrosting: compartment: Freezer
automatic
compartment:
Refrigerator
yes
Interior light: compartment: Freezer
no
compartment:
SuperCool: no

SuperFrost: Automatic (time-controlled)

Service menu: Start by button combination

Refrigerating system: 1 standard compressor with solenoid valve


Page 3 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

3.0 Description of the appliance


The CN(es) ..03 is a combined refrigerator-freezer with a NoFrost freezer compartment. The appliance has a
compressor. The refrigerator and freezer compartment evaporator is activated via a bi-stable solenoid valve.
Both evaporators are connected in series (see 3.3 Schematic diagram: Refrigerating circuit).
Therefore the refrigerator compartment can be operated only in conjunction with the freezer compartment.
However, it is possible to operate the freezer compartment on its own.

3.1 Refrigerator compartment:


The refrigerator compartment is equipped with a foamed-in evaporator and an evaporator sensor. The sensor is
separately replaceable.
The evaporator sensor is responsible for switching off the refrigeration, sees to the defrosting of the refrigerator
compartment evaporator and switches the refrigeration on.
A fan is optionally activatable for even temperature distribution.

Only CN(es)

Fig. 3.1 Schematic diagram


refrigerator compartment

3.2 NoFrost freezer compartment


The freezer compartment is equipped with a NoFrost rear wall evaporator module, fan module, air sensor and
evaporator sensor. Both sensors are separately replaceable. The defrosting phases are initiated by way of the
electronic control system, taking compressor running time and door openings into account.

Reed switch
Fan

Air sensor .

Evaporator

Evaporator sensor

Compressor

Fig. 3.2 Schematic diagram NoFrost freezer compartment

Page 4 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

3.3 Refrigerating circuit

Condenser Refrigerator

Fig. 3.3 : Schematic diagram refrigerating circuit

Page 5 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

4.0 Control and functional


components
4.1 Refrigerator compartment
Electronic control system: Series 3 electronic control system: integral PCB.

Setting range: +9C / +7C / +5C / +3C / +1 C

Display range: 9C / 7C / 5C / 3C / 1C * (set value display)


Door alarm:
When: After the refrigerator compartment door has been open for 60 secs.
Audible: 3 beeps.
Interior light:
Position: Inside left.
Function: - Is switched on as soon as refrigerator compartment door is opened.
- Is switched off after door has been open for 15 minutes.
Reed PCB: Position: In front panel.
Function:- Switches the interior light on when the door is opened.
- Switching contact for door alarm.
Only CN(es) 3303 / 3803 from -21
- Switches the fan (if activated)
off when the door is opened.
Evaporator sensor:
Position: Behind cover, on rear wall, level with light housing.
Function:- Refrigerator compartment evaporator sensor or freezer
compartment air sensor switches the compressor ON.
- Refrigerator compartment evaporator sensor and freezer
compartment air sensor switch the compressor OFF.
- Switches solenoid valve to position A (refrigerator + freezer
compartment)
- Switches solenoid valve to position B when the switch-off valve is
reached (freezer compartment only)
Fan:
CP(es) 3303/3803 from Position: At the centre back of the ceiling of the compartment liner.
Index -21 Function:ON: - Fan switch ON and
- compressor ON and
- refrigerator compartment door closed and
- solenoid valve at position A (refrigerator + freezer
compartment)
OFF: - Fan switch OFF or
- compressor OFF or
- refrigerator compartment door open or
- solenoid valve at position B (freezer compartment)
During start-up the fan is activated only from an evaporator sensor
temperature of +12C and colder.

Defrosting:
Automatic during standstill phase of the compressor. Automatic when solenoid
valve is set to position B (freezer compartment).
Compressor:
Function: ON: - Refrigerator compartment evaporator sensor switch-
on value or
- freezer compartment air sensor switch-on value.
Note: On-delay time (8 mins.) must have elapsed.
OFF: - Refrigerator compartment evaporator sensor switch-
off value and
- freezer compartment air sensor switch-off value

Page 6 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

4.2 NoFrost freezer compartment


Electr. control system: See 4.1 Refrigerator compartment.

Setting range: -15C / -18C / -21C / -25C / -32C

Display range: -15C / -18C / -21C / -25C / -32C (set value display)
Temperature alarm:
When: measured sensor temperature is 7K warmer than set value
(e.g. set value: -18C, actual value for 90 min. at 11C ^ alarm)
SuperFrost alarm value: Actual value = -10C

Audible: 4 beeps (suppressed for 90 min. during start-up)


During startup the alarm LED is permanently lit (acknowledged alarm), the
audible alarm is switched off.
After defrost end the alarm is suppressed for 30 min.

Door alarm:
When: With open freezer compartment door after 60 secs.
Audible: 3 beeps.
Reed PCB:
Position: In freezer compartment fan housing.
Function: - Turns off the fan when the door is opened.
- Switching contact for door alarm.
Fan:
Position: At top in middle of freezer compartment.
Function: ON: - compressor on and
- freezer compartment door closed and
- evaporator sensor switch-on value reached.
Switch-on value evaporator sensor:
a) During start-up / after defrosting phase: -25C.
b) in normal operation 2K colder than freezer compartment air sensor.
OFF: - Compressor off or
- freezer compartment door open.

Air sensor:
Position: In sensor holder on air duct cover.
Function: - Freezer compartment evaporator sensor or refrigerator
compartment air sensor switches the compressor ON.
- Freezer compartment air sensor and refrigerator compartment
evaporator sensor switch the compressor OFF.
Evaporator sensor:
Position: Inserted into lamellar evaporator.
Function: - Ends the defrosting phase.
- Switches the freezer compartment fan on.
Evaporator heater:
Only one heater for evaporator and defrost water drain channel.
Safety temperature restrictor, connected in series with heater.
Activated via electronic control system (see Defrosting).

Page 7 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

Defrosting: The defrosting phase is started:


- During start-up after 6 hours cumulative compressor running time.
- After a cumulative compressor running time of 12 to a maximum of
60 hours, depending on the number/duration of the door openings.
When the defrosting phase begins, the compressor and the fan are switched off
and the defrosting heater is switched on.
The defrosting heater remains switched on until:
- the evaporator has reached +5C or
- 50 minutes have elapsed.
After the end of the heating phase, the compressor is switched on with a
10 minute delay.
If the SuperFrost function is activated during the defrosting phase, this will not
interrupt defrosting.

Water drain valve:


Foamed in water drain, water drain valve can be drawn off for cleaning
purposes
(see 7.2.4 Assembly instructions water drain valve).

SuperFrost: Cooling of freezer compartment to -37C (65 hours).

Compressor: See 4.1 Refrigerator compartment -compressor-

5.0 Refrigeration circuit


5.1 Refrigerator compartment
Evaporator: Rear wall evaporator, foamed in.
Injection
Solenoid valve in position A (refrigerating + freezing):
point / flow
Introduction of refrigerant in refrigerator compartment evaporator top left, then
sequence:
transition to freezer compartment evaporator.
Solenoid valve:
2 capillary tubes (long coil refrigerator compartment, short coil freezer
compartment).

Compressor: 1 standard compressor.


On-delay time of 8 mins.

5.2 NoFrost freezer compartment

Evaporator: Lamellar evaporator, in the rear wall of the freezer compartment.


The defrosting heater is attached directly to the evaporator.

Solenoid valve in position B (freezing):


Injection point:
Top left on lamellar evaporator.

Solenoid valve: See 5.1 Refrigerator compartment -solenoid valve-.

Compressor: See 5.1 Refrigerator compartment -compressor-.

Frame heater: Foamed-in liquid heater in area of freezer compartment door.

Page 8 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

6.0 Special features


6.1 Solenoid valve
6.1.1 Electrical actuation of the solenoid valve
With this model a bi-stable solenoid valve is used. This means that after actuation the solenoid valve maintains
the respective switching state.

To sum up:
To check actuation of the solenoid valve, we recommend using the service menu (see 9.3 Service mode "L" ).
Here the switching of the solenoid valve can be clearly heard.

6.1.2 Schematic diagrams solenoid valve

Freezer compartment Refrigerator compartment and freezer


addressed compartment
addressed

Fig. 6.1.2 / 2

7.0 Assembly instructions


7.1 Refrigerator compartment
7.1.1 Evaporator sensor
Evaporator sensor: - Undo screw of the evaporator sensor cover (see Fig. 7.1.1/ 1)
- Remove evaporator sensor cover.
- Undo marked screw for evaporator sensor mount (see Fig. 7.1.1/ 2).
- Disengage evaporator sensor.

Fig. 7.1.1/ 1 Fig. 7.1.1/ 2

Page 9 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

7.1.2 CN(es) 3303 / 3803 from -21 fan


Fan: - Undo fastening screws of the fan (see Fig. 7.1.2/ 1).
- Pull off connecting cable, unlock fan switch (see Fig. 7.1.2/ 2) and press out
forwards.
- Remove air guide plate from fan housing (see Fig. 7.1.2/ 3).
- Remove fan from motor mount.
- Cable routing in fan housing (see Fig. 7.1.2/ 5) for installation.

fan

Fig. 7.1.2/ 4 Fan motor

Fig. 7.1.2/ 5 Cable routing

Page 10 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

7.2 NoFrost freezer compartment


7.2.1 Air sensor, evaporator module and fan module

Air sensor: Engaged in sensor holder on air duct cover.

Evaporator module: Remove drawers and glass shelves in freezer compartment, detach air sensor, un
screw the Torx screws marked in the picture with an arrow and remove the rear
wall. By releasing the plastic screw arrow 1, the evaporator module can be lifted
and drawn forwards.

Fan module: Undo plastic screws arrow 2 and 3. Also undo Torx screws arrows 4 and 5, then the
fan module can be swung out.

Air duct panel

i
*
(((ii?
*
If

t \
Fig. 7.2.1/ 1 Freezer compartment with air duct Fig. 7.2.1/ 2 Freezer compartment without air

,t Air sensor

Page 11 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

7.2.2 Temperature fuse, evaporator sensor and defrosting heater

Temperature fuse: The temperature fuse can be replaced separately with a conversion kit.
The conversion kit comprises: - 1 temperature fuse
- 2 pressure connectors
- 2 shrinkdown tubings
Please note:
Always attach the compression joint to the red and blue lines of the temperature
fuse. As soon as the white line of the defrosting heater is cut, the defrosting heater
is destroyed.

Evaporator sensor: Is inserted into lamellar evaporator.

Defrosting heater: Is clipped into the evaporator fins. Can be replaced if defective.

Temperature fuse

mi nmimwi

Evaporator sensor

Fig. 7.2.2 Evaporator module

7.2.3 Fan and reed PCB


Fan: The fan is inserted in the plastic module with rubber buffers. The line is equipped
with a removable plug.

Reed PCB: The reed switch is inserted in the fan module.

Fig. 7.2 .3/ 1 Fan module Fig. 7.2 .3/ 2 Fan module with reed PCB

Page 12 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

7.2.4 Water drain valve


The water drain valve is accessible from the compressor niche. It is situated just above the
evaporation tray of the compressor.

7.3 Solenoid valve

Permanent magnets

Attention: insert correctly

\
The magnets must repel each other.

Fig. 7.3 Solenoid valve

@ Refrigerator compartment (C

Dryer
Freezer compartment

Refrigerating connections are printed on the solenoid valve cover:

KS: Refrigerator compartment capillary


GS: Freezer compartment capillary

Page 13 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

7.4 Integral PCB

Covers: Disengage covers.

Fig. 7.4/ 1 Fig. 7.4/ 2

Front panel: Undo screws of front panel.

(
Fig. 7.4 / 4

Fig. 7.4/ 3

Sensor cable: Detach sensor cable from cable clamp.

Fig. 7.4 / 5

PCB carrier: Disengage PCB carrier of the integral PCB from the front panel at the marked points,
in the order indicated.

Fig. 7.4 / 6

Page 14 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

After unlocking, swing the PCB carrier out of the front panel in the arrow direction.

Fig. 7.4 / 7

Integral PCB: Disengage integral PCB from PCB carrier at the marked points.

Fig. 7.4/ 8

Page 15 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

8.0 Technical data


8.1 Refrigerator compartment

Interior light: Wattage: 25 watts


Voltage: 230 volts
Socket: E14

Fan: Wattage: 5.8 watts


Only CN(es) Voltage: 230 volts
3303/3803 Speed: 1700 rpm
from -21
Sensor values: Evaporator sensor

Temperature C Resistance value kOhm


+35 3.1
+30 3.8
+25 4.7
+20 5.9
+15 7.3
+10 9.3
+5 11.9
0 15.3
-5 19.8
-10 25.9
-15 34.1
-20 45.3
-25 60.8
-30 82.3
-35 112.8

8.2 NoFrost freezer compartment


Fan: Wattage: 4 watts
Voltage: 230 volts

Speed: 2150 rpm winding not measurable through connections


(electronic fan)
Solenoid valve: Voltage: 230 volts (actuated with half-waves)
Resistance: 2.8 kOhm, at +20C

Defrosting heater: Wattage: 132 watts


Voltage: 230 volts

Current: 0.55 amperes

Resistance: 404 ohms, (+20C)

Protection against - +93C, in series with defrost heater


overheating: - Cannot be reactivated and, once actuated, it has to be replaced
Sensor values: Air and evaporator sensor See 8.1 Refrigerator compartment.

Page 16 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

9.0 Service menu

The service menu may be used only by customer service technicians.

Start conditions: Both rotary buttons have to be set to 0.

9.1 NoFrost freezer compartment defrosting "-15C LED" (evaporator must be cold)
Keep SuperFrost depressed and turn freezer compartment control button from 0 to the right until
SuperFrost LED flashes.
Set control button so that -15C LED is lit, SuperFrost flashes.
Press SuperFrost, the appliance is now in defrost mode.
The defrosting phase is started.
The defrosting phase is complete as soon as the evaporator reaches +5C or after 50 minutes.
The appliance automatically switches back to normal operation.
The defrosting phase can be ended prematurely by switching the appliance off and on again.

9.2 Demo mode


Keep SuperFrost depressed and turn freezer compartment control button from 0 to the right until
SuperFrost LED flashes.
Now turn until the -18C LED is lit.
-18C LED is lit = demo mode is deactivated.
To activate the demo mode, press SuperFrost.
-18C LED flashes = demo mode is activated.
To deactivate the demo mode, press SuperFrost.
If no change is wanted, do not press SuperFrost, but set the control button to "0".
When the demo mode is active, the compressor is not addressed.
Attention: The demo mode cannot be deactivated by power OFF/ON. This is possible only via the
service menu.

Page 17 of 18
Service Information No. 02/2006 (Version 01) CN(es) ..03

9.3 Service mode


Keep SuperFrost depressed and turn freezer compartment control button from 0 to the right until
SuperFrost LED flashes.
Now turn until the -21C LED is lit.

Press SuperFrost, service mode is active.


Open and close both doors. LEDs light up in groups.
Turn both control buttons from "0" to "max". LEDs light up in groups.
Press each button. LEDs light up in groups.
All the loads can be addressed individually using the SuperFrost button.
SuperFrost LED flashes alternately with
o 9C / -15C o LED No load addressed
-18C o 7C LED Compressor ON, solenoid valve in position B (freezer compartment)
Compressor ON, solenoid valve in position A (refrigerator compartment +
LED
freezer compartment)
o -21 CLED: Fan freezer compartment Defrost
o -25CLED: heater freezer compartment Light ON
o 1C/-32CLED: Fan ON, when fan switch is set to ON
o 5C LED:
End: Set both control buttons to "0".

10.0 Table of error codes


Error code Audible Alarm LED Defective component Emergency operation
alarm
SFLED
2 Hz in Evaporator sensor for Refrigerator compartment is
yes no
synchronism with refrigerator compartment cyclically controlled
3C LED
SFLED
2 Hz in Freezer compartment air Compressor continuous
yes no
synchronism with sensor operation
-15C LED
SFLED
2 Hz in Evaporator sensor, freezer Compressor continuous
yes no
synchronism with compartment operation
-18C LED

The audible alarm can be switched off with the alarm OFF button.

Page 18 of 18