You are on page 1of 41

COMIMSA Module 10

Module 10

Visual Inspection and other NDE


Methods and symbols
COMIMSA Module 10

1. Introduction

Under some specifications, a knowledgeable welding inspector has the

authority to accept welds by visual examination alone.

Some of the welds in a structure, however can not be easily certified.

The welding inspector can employ one or more of the following methods

to collect the necessary evidence for specification compliance:

1) NDE - ASNT SNT TC 1A


2) Chemical Analysis qualified to ASTM standards.
3) Metallurgical Analysis
4) Mechanical Testing
COMIMSA Module 10

1. Introduction

There are three principal features to be considered when choosing an

examination method:

1) Limitations of the examination methods

2) Acceptance standards.

3) Economics
COMIMSA Module 10

2. Visual Examination

It has been shown that an effective program of visual inspection results in

the early discovery of most defects that, if left undetected, would later be

found by using a more costly method of NDE

Visual examination is limited to the detection of surface discontinuities.

However, when conscientiously applied before, during, and after welding.


COMIMSA Module 10

2. Visual Examination

Preventing discontinuities before a weld is complete is one of the most

important features of visual examination


COMIMSA Module 10

2. Visual Examination
COMIMSA Module 10

2. Visual Examination
COMIMSA Module 10

2. Visual Examination
COMIMSA Module 10

2. Visual Examination
COMIMSA Module 10

2. Penetrant Testing (PT)


Penetrant testing is a sensitive method used for locating discontinuities,

such as crack and porosity in non porous materials.

Clean discontinuities open to the surface (precleaning).

Penetrant liquid is applied to the surface to be examined (dwell time)

The excess of penetrant is then cleaned from the test surface.

Developer powder is applied.

ASTM E165, Standard Practice for Liquid Penetrant Inspection


COMIMSA Module 10

2. Penetrant Testing (PT)

Following the application and drying

of the developer, all indications are

evaluated accordance with

applicable specification.
COMIMSA Module 10

2. Penetrant Testing (PT)


COMIMSA Module 10

2. Penetrant Testing (PT)


Uses

Magnetic materials and non magnetic which cannot be examined by


magnetic particle.

Advantages

Inexpensive and quick


Process simple
Few false or nonrelevant indications on smooth surfaces

Limitations

Discontinuities must be clean and open to surface


Deleterious substances used in penetrants on welds and base
metals
Difficult to remove from discontinuities
Weld surface should be ground smooth before inspection
COMIMSA Module 10

3. Magnetic Testing (MT)


Is used for locating surface or near surface discontinuities in
ferromagnetic materials.

This method involves the establishment of a magnetic field within the


material and can be examined with:

Prods

Yokes

Coils

ASTM E709, Guide for Magnetic Particle Inspection


COMIMSA Module 10

3. Magnetic Testing (MT)


COMIMSA Module 10

3. Magnetic Testing (MT)

The electric field to generate the magnetic field can be:

Current Discontinuities Comments


AC Surface Improved sensitivity in rough surfaces
Slightly below
DC
surface
Surface and Benefits of both types of magnetizing
HWAC
below surface currents
COMIMSA Module 10

3. Magnetic Testing (MT)


COMIMSA Module 10

3. Magnetic Testing (MT)


Uses

Quality of welds, can detect:

Surface cracks in the weld or metal base


Laminations or other discontinuities on the prepared edge of the
metal base
Incomplete fusion
Undercut
Subsurface cracks

Advantages

Reveals discontinuities not open to the surface or filled with some


substance
Faster and more economical than PT
Require less cleaning prior to examination
COMIMSA Module 10

3. Magnetic Testing (MT)

Limitations

Applicable only to ferromagnetic materials

Difficulties in weldments where the magnetic characteristics of the

deposited weld metal differ appreciably from those of the base metal.

Difficulties where the magnetic field is not properly oriented.

Indications in dissimilar metals joints

Must be applied in at least two directions


COMIMSA Module 10

4. Radiographic Testing (RT)

The application of radiography for weld

examination depends on:

Weld joint location


Joint configuration
Material thickness
Radiography uses X ray or gamma radiation that penetrates through the

part and produces an image on a film or plate. Selection of the radiation

source for a particular thickness of weld is a critical factor.

ASTM E94, Standard Recommended Practice for Radiographic Testing


COMIMSA Module 10

4. Radiographic Testing (RT)


COMIMSA Module 10

4. Radiographic Testing (RT)

The use of a variable light intensity viewer is helpful when viewing and
analyzing radiographs.

Determining the film density at various points is also necessary and is


usually accomplished through the use of a device referred to as
densitometer.

To indicate the acquired sensitivity of a given radiography a device


referred as an image quality indicator (IQI) is placed adjacent to the area
of interest.
COMIMSA Module 10

4. Radiographic Testing (RT)


There are two types of IQIs :

Shim type - holes


Wire type - wires

The sensitivity of the radiograph

is determined by which one of the

three holes, or wire diameters is

visible on the radiograph.


COMIMSA Module 10

4. Radiographic Testing (RT)


There are two types of IQIs :
COMIMSA Module 10

4. Radiographic Testing (RT)


Advantages

RT can detect surface and subsurface discontinuities

Limitations

As the joint becomes more complex increase the cost and decrease
the amount of information.

Discontinuities must be approximately aligned with the radiation


beam.

Laminations and lamellar tearing are rarely detected.

Initial setup for this testing requires a high capital expense.

Radiation Hazard
COMIMSA Module 10

5. Ultrasonic Testing (UT)

The ultrasonic methods uses the transmission of mechanical energy in


wave form at frequencies above the audible range.

Reflections of this energy by discontinuities in metals are detected.

ASTM E1032, Radiographic Examination of Weldments


COMIMSA Module 10

5. Ultrasonic Testing (UT)


Uses

In the pulse-echo technique:

A transducer transmits a pulse of high frequency sound into the


material

The reflected sound is received from a discontinuity, the opposite


surface or other surfaces of the part.

The reflected sound is received as an echo which, together with the


original pulse, is displayed on the screen of a cathode ray tube
(CRT).
COMIMSA Module 10

5. Ultrasonic Testing (UT)


Uses
COMIMSA Module 10

5. Ultrasonic Testing (UT)

Uses

Before testing, the instrument to be

used must be calibrated against a

reference standard.
COMIMSA Module 10

5. Ultrasonic Testing (UT)


Uses

When a sound beam intercepts the plane of discontinuities at or near 90,


a maximum reflected signal will return to the transducer.

In scanning welds, this is achieved by angle beams into the work, though
a Lucite wedge and into the work through water, oil, or similar coupling
material

The equipment must be calibrated using a standard reference block,


such as the IIW calibration block.
COMIMSA Module 10

5. Ultrasonic Testing (UT)

Advantages

Detect both surface and subsurface discontinuities

For pulse-echo testing, access is necessary to only one side of the


work.

The size of flaws and their location may be determined quantitatively

More sensitive than RT to planar discontinuities


COMIMSA Module 10

5. Ultrasonic Testing (UT)

Limitations

Materials with large grain size tend to scatter and disperse the sound
beam.

The scan pattern must be sufficient to pass the projected sound


beam through the entire volume of the weld and HAZ to permit
detection of possible discontinuities.

For contact testing, surface must be smooth

Personnel require more training and experience


COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)

ET requires that the part under test be subjected to the influence of an


alternating electromagnetic field.

This test detects surface or subsurface discontinuities in any material that


is an electrical conductor.
COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)

The electromagnetic field induces

eddy current and also magnetic

fields.

Information gathered by probe


coils is transmitted to a test circuit
and analyzed electronically

Electromagnetic field frequency


are usually in the range of 500
5000 hertz.
COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)


Uses

ET is employed on magnetic or

nonmagnetic materials.

The magnitude and direction of


the eddy currents are detected
by the coil which acts through
electronic circuitry to register
the discontinuity.

If a variation in flux is
associated with discontinuities
in the material, the
discontinuities are detected.
COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)

Advantages

Automate examination at high speed and relatively low cost.

Indications produced are proportional to the actual size of the


discontinuity.

Contact of probes with the work is unnecessary. .


COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)

Advantages
ET can detect many material characteristics:

Electrical conductivity

Magnetic permeability

Thickness of a nonconductive coating.

Alloy content

Heat Treatment

Presence of discontinuities at or below the surface.


COMIMSA Module 10

6. Eddy Current (Electromagnetic) Testing (ET)

Limitations

Any magnetic or electrically conductive surface dirt must be removed


before inspection.

Design of the coil appropriate for shape of the component to be tested.

Limit of penetration in nonmagnetic metals is approximately below


the surface.
COMIMSA Module 10

7. NDE Symbols
COMIMSA Module 10

7. NDE Symbols
COMIMSA Module 10

7. NDE Symbols

You might also like