You are on page 1of 41

Computer Based Training Module

Flow-Accelerated Corrosion for


non-FAC Personnel

March 2006
Introduction to Navigation

Module can be navigated in a linear fashion


Click Page Down or Enter
By following hyperlinks for more information
The file must be viewed in Slide Show mode for the
hyperlinks to work
Click on a hyperlink to go directly to related information
in the training, clicking page down or enter will take you
back to where you left off

2006 Electric Power Research Institute, Inc. All rights reserved. 2


Introduction to Flow-Accelerated Corrosion

Flow-accelerated corrosion (FAC) is a corrosion process


that degrades carbon steel material
FAC normally occurs above room temperature under
specific chemistry conditions normally found in power
plants
FAC requires that flowing water or water/steam mixtures
be in contact with the steel surface
FAC is normally related to turbulence especially near
fittings, e.g., elbows, orifices, valves

2006 Electric Power Research Institute, Inc. All rights reserved. 3


Description of FAC

FAC occurs when the normally protective iron-oxides


dissolve into the flowing stream
This results in a global attack (i.e., widespread thinning)
rather than local attack (i.e., pitting or cracking)
FAC caused failures are often sudden and catastrophic
Damage rates caused by FAC are dependent on the
water chemistry indicating that FAC is a corrosion process
not mechanical in nature (Information on Erosion)
For more details on the FAC Process

2006 Electric Power Research Institute, Inc. All rights reserved. 4


Why is FAC Important?

FAC has caused damage and has resulted in


Failures
Workmen killed or injured
Piping and equipment replacements
This experience has necessitated expensive plant
programs

2006 Electric Power Research Institute, Inc. All rights reserved. 5


Significant Experience Surry Unit 2

An 18 inch elbow in a condensate line ruptured catastrophically


in 1986
Four fatalities and several injuries resulted

Flow was from left to right


2006 Electric Power Research Institute, Inc. All rights reserved. 6
Significant Experience Mihama Unit 3

A 22 inch condensate
line downstream of an
orifice ruptured
Catastrophically in 2004

Five fatalities and


several injuries resulted
Flow from right to left.
Note orifice flange is at right edge of photo

More piping experience slide show


2006 Electric Power Research Institute, Inc. All rights reserved. 7
Significant Experience Point Beach 1

FAC also occurs in


equipment, particularly
feedwater heater
shells

Operating Conditions = 347F and about 88% quality

2006 Electric Power Research Institute, Inc. All rights reserved. 8


What Does FAC Damage Look Like?

Under single-phase (i.e.,


water only) conditions, the
damaged surface displays
a scalloped or orange-
peel surface
This type of surface is
conclusive evidence that
the damage is caused by
FAC
Depending on the
conditions, magnification
may be required to view Single-Phase FAC
Note 50m 0.002
the scalloping

2006 Electric Power Research Institute, Inc. All rights reserved. 9


What Does Damage Look Like?
(continued)

Under high quality,


two-phase conditions,
the surface may show
a pattern of dark and
light areas known as
tiger stripping
Tiger-striping is also
conclusive evidence of
FAC
More tiger striping
slide show
EDF Tiger Striping

2006 Electric Power Research Institute, Inc. All rights reserved. 10


Susceptibility Considerations Systems

Generally all of the secondary side in PWRs and the


equivalent BWR systems are susceptible to damage
Some BWR auxiliary systems (e.g., RHR) may also be
susceptible
Auxiliary systems such as building steam may also be
susceptible

2006 Electric Power Research Institute, Inc. All rights reserved. 11


Susceptibility Considerations Piping

Piping is susceptible to FAC if:


The material is carbon steel
There is water or wet steam flowing in the pipes
The water is deoxygenated (i.e., service water systems
do not experience FAC)
Note that both large bore (> 2 NPT) and small bore
piping systems are susceptible
More detail on small bore piping

2006 Electric Power Research Institute, Inc. All rights reserved. 12


Susceptibility Considerations Equipment

Carbon steel equipment in susceptible systems are


normally susceptible, especially:
Feedwater heaters slide show
MSR and other tanks slide show
Steam generator internals in PWRs slide show
Turbine casings

2006 Electric Power Research Institute, Inc. All rights reserved. 13


Known Problem Areas

Downstream of control valves


Downstream of level control valves e.g. Millstone 2 & 3
Downstream of flowmeters especially orifices
e.g. Mihama
Downstream of leaking valves and steam traps
Crossunder lines

2006 Electric Power Research Institute, Inc. All rights reserved. 14


Known Problem Areas
(continued)

Unknown materials of construction (i.e., documentation


shows FAC-resistant materials but really carbon steel)
Unknown piping components (i.e., insulation hides pipe
spool pieces or other components which may be wearing
at different rates than inspected piping)
Undocumented replacements (i.e., components were
replaced and no records kept). This can result in improper
wear predictions.

2006 Electric Power Research Institute, Inc. All rights reserved. 15


Plant Programs General

Programmatic recommendations for FAC programs are


found in the current revision of NSAC-202L
Recommendations for an Effective Flow-Accelerated
Corrosion Program
Interaction with other groups is a key part in successful
programs
Details on such interactions

2006 Electric Power Research Institute, Inc. All rights reserved. 16


Plant Programs Analysis

A susceptibility analysis is performed to determine the


extent of the plant program
CHECWORKS analysis to predict FAC damage rates in
susceptible systems, and predict component lifetimes
CHECWORKS also provides a comparison of predicted
and measured wear rates

2006 Electric Power Research Institute, Inc. All rights reserved. 17


Plant Programs Inspection

Large bore piping is normally inspected using the


ultrasonic inspection technique (UT), but occasionally
radiographic technique (RT) is used
Small bore piping is normally inspected using RT or by
UT scanning
Visual inspections (VT) are used under special
circumstances
CHECWORKS is normally used to store and manage
the UT inspection data

2006 Electric Power Research Institute, Inc. All rights reserved. 18


Plant Programs Other Elements

All components are evaluated for acceptance for


continued service
Repair/replacements decisions must be made, often
during outages. This process is dependent on the
component evaluation process.
Reinspection intervals for all components must be
determined
Future inspection and replacement scopes must be
determined

2006 Electric Power Research Institute, Inc. All rights reserved. 19


Ultrasonic Testing (UT) Practices

Large bore inspections are performed on a grid


Templates are sometimes used in place of a drawn grid
Hand-held instruments are used to take and record data
Data is usually analyzed using CHECWORKS
Hot UT, measurements during operation, is occasionally
used

2006 Electric Power Research Institute, Inc. All rights reserved. 20


Radiographic Testing (RT) Practices

Many utilities are still using film, but a number of utilities


are moving to the newer phosphor plate (digital) imaging
technique
Data interpretation and manipulation are easier with
digital images
Two measurement techniques are used
through wall usually used to determine the wall
thickness of large bore piping
tangential wall usually used for small bore piping
EPRI research is being directed at increasing the size
limits of through wall RT

2006 Electric Power Research Institute, Inc. All rights reserved. 21


Visual Inspection Practices

Among the specific areas where visual techniques are


used:
Crossunder normally done during crawl through of
piping
When valves and pumps are opened for maintenance,
the opportunity may be used to perform a visual
inspection
When a piece of equipment (e.g., feedwater heater) is
opened for maintenance, the opportunity may be used
to perform a visual inspection

2006 Electric Power Research Institute, Inc. All rights reserved. 22


Vessel Inspections Feedwater Heaters

The most commonly inspected vessels are feedwater


heater shells
There are several methods used to inspect vessels.
These are:
UT with grids insulation is removed, vessel is
gridded, data is taken
UT scans insulation is removed, and scans are made
and data recorded

2006 Electric Power Research Institute, Inc. All rights reserved. 23


Vessel Inspections Feedwater Heaters
(continued)

Pulsed Eddy Current is used through the insulation


Pulsed Eddy Current is used through the insulation. A
small portion of the insulation is removed an UT
measurements in this area are used to calibrate the PEC
measurements.
Automatic techniques using computer controlled
carriage to perform UT measurements
More information on heater inspections

2006 Electric Power Research Institute, Inc. All rights reserved. 24


What to Do if There is a Leak?

For large bore piping, leak before break does not


normally occur
Sudden, catastrophic failure is possible
Evacuate personnel and rope-off the area surrounding the
leak
Notify management
Notify FAC program owner

2006 Electric Power Research Institute, Inc. All rights reserved. 25


Material Considerations

Alloying elements can reduce the rate of FAC over


unalloyed carbon steel
Chromium has been shown to be the most important
alloying element with copper and molybdenum also
providing resistance
Some plants use alloy analyzers to account for trace alloy
content in their FAC programs

2006 Electric Power Research Institute, Inc. All rights reserved. 26


Materials Considerations
(continued)

Resistance to FAC has been shown to be well


represented by this bar graph

2006 Electric Power Research Institute, Inc. All rights reserved. 27


Replacement Considerations

The cost and availability of the material


The resistance to FAC (previous slides)
Thermal expansion of stainless steel versus carbon steel
may require a new pipe stress analysis
Welding issues including pre- and post-weld heat
treatment issues with chrome-moly material

2006 Electric Power Research Institute, Inc. All rights reserved. 28


Repair Options Piping

On piping and fittings, weld overlay may be used for


temporary repairs
For crossunder piping, there are several repair options:
Weld overlay
Flame/arc spraying
Slide show

2006 Electric Power Research Institute, Inc. All rights reserved. 29


Repair Options Feedwater Heater Shells

The approach used for repairing shells is called a


Window Repair cutting out a section of the shell and
replacing with a piece of rolled plate
Cap Repairs using engineered caps are sometimes
used
Slide show

2006 Electric Power Research Institute, Inc. All rights reserved. 30


Water Chemistry

Water chemistry is a key parameter in controlling the rate


of FAC
Oxygen, pH and hydrazine influence the rate of FAC
The specifics depend on the type of reactor system
BWR Chemistry
PWR Chemistry

2006 Electric Power Research Institute, Inc. All rights reserved. 31


Iron Transport

FAC is responsible for the generation of most of the iron


that is transported to the SG/BWR vessel
Calculations and experience show that this iron comes
primarily from equipment not piping
More information about iron transport

2006 Electric Power Research Institute, Inc. All rights reserved. 32


Where to Go for More Information

Unit program owner ______________ (filled in by utility)


FAC Book current revision a compendium of
information on FAC
NSAC-202L current revision programmatic information

2006 Electric Power Research Institute, Inc. All rights reserved. 33


Quiz

1. Would you expect FAC to occur in the feedwater system of fossil


plants? Hint the conditions are similar to the conditions in the
feedwater system of PWRs.
Yes
No
2. Would you expect FAC to be worse near an elbow or in an isolated
straight pipe?
Elbow
Pipe
3. What would be the best strategy for protecting a line Replace one
or two components with stainless steel or improve the water
chemistry?
Replace
Water Chemistry

2006 Electric Power Research Institute, Inc. All rights reserved. 34


Quiz

4. Is there an erosive component to FAC damage?


Yes
No
5. Inspection programs are the main part of a FAC program.
True
False
6. Which of the following parameters influence the rate of FAC?
a. Velocity
b. Local geometry
c. Wall material
d. Water chemistry
e. All of the above

2006 Electric Power Research Institute, Inc. All rights reserved. 35


Quiz

7. What are the inspection methods most commonly used


to locate FAC caused degradation?
a. UT for large bore
b. Hot UT for large bore
c. RT for small bore
d. Visual for special circumstances
e. All of the above
f. Items a, c & d
8. FAC damage always appears as tiger striping.
True
False

2006 Electric Power Research Institute, Inc. All rights reserved. 36


Quiz

9. FAC affects piping and equipment such as feedwater


heaters.
True
False
10. FAC caused damage may result in:
Piping failures
Equipment failures
High iron transport
Piping replacements
All of the above

2006 Electric Power Research Institute, Inc. All rights reserved. 37


Training Complete

2006 Electric Power Research Institute, Inc. All rights reserved. 38


DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
THIS DOCUMENT WAS PREPARED BY THE ORGANIZATION(S) NAMED BELOW AS AN ACCOUNT OF WORK
SPONSORED OR COSPONSORED BY THE ELECTRIC POWER RESEARCH INSTITUTE, INC. (EPRI). NEITHER EPRI,
ANY MEMBER OF EPRI, ANY COSPONSOR, THE ORGANIZATION(S) BELOW, NOR ANY PERSON ACTING ON
BEHALF OF ANY OF THEM:
(A) MAKES ANY WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, (I) WITH RESPECT TO
THE USE OF ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS
DOCUMENT, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR (II) THAT SUCH USE
DOES NOT INFRINGE ON OR INTERFERE WITH PRIVATELY OWNED RIGHTS, INCLUDING ANY PARTY'S
INTELLECTUAL PROPERTY, OR (III) THAT THIS DOCUMENT IS SUITABLE TO ANY PARTICULAR USER'S
CIRCUMSTANCE; OR
(B) ASSUMES RESPONSIBILITY FOR ANY DAMAGES OR OTHER LIABILITY WHATSOEVER (INCLUDING ANY
CONSEQUENTIAL DAMAGES, EVEN IF EPRI OR ANY EPRI REPRESENTATIVE HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES) RESULTING FROM YOUR SELECTION OR USE OF THIS DOCUMENT OR ANY
INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS DOCUMENT.
ORGANIZATION(S) THAT PREPARED THIS DOCUMENT
EPRI Solutions

NOTICE: THIS REPORT CONTAINS PROPRIETARY INFORMATION THAT IS THE INTELLECTUAL PROPERTY OF
EPRI, ACCORDINGLY, IT IS AVAILABLE ONLY UNDER LICENSE FROM EPRI AND MAY NOT BE REPRODUCED OR
DISCLOSED, WHOLLY OR IN PART, BY ANY LICENSEE TO ANY OTHER PERSON OR ORGANIZATION.

NOTE
For further information about EPRI, call the EPRI Customer Assistance Center at 800.313.3774 or e-mail
askepri@epri.com.
Electric Power Research Institute and EPRI are registered service marks of the Electric Power Research Institute, Inc.
Copyright 2006 Electric Power Research Institute, Inc. All rights reserved.
CITATIONS

This report was prepared by


EPRI Solutions
1661 Page Mill Rd
Palo Alto, CA 94304
Principal Investigator
J. Horowitz
T. Taylor
This report describes research sponsored by the Electric Power Research Institute (EPRI).
The report is a corporate document that should be cited in the literature in the following manner:
Computer-Based Training Module on Flow-Accelerated Corrosion (FAC) for non-FAC Personnel. EPRI, Palo Alto, CA:
2006. 1013249.
Export Control Restrictions The Electric Power Research Institute (EPRI)
Access to and use of EPRI Intellectual Property is granted with The Electric Power Research Institute (EPRI), with
the specific understanding and requirement that responsibility major locations in Palo Alto, California, and Charlotte,
for ensuring full compliance with all applicable U.S. and North Carolina, was established in 1973 as an
foreign export laws and regulations is being undertaken by independent, nonprofit center for public interest energy
you and your company. This includes an obligation to ensure and environmental research. EPRI brings together
that any individual receiving access hereunder who is not a members, participants, the Institutes scientists and
U.S. citizen or permanent U.S. resident is permitted access engineers, and other leading experts to work
under applicable U.S. and foreign export laws and collaboratively on solutions to the challenges of electric
regulations. In the event you are uncertain whether you or power. These solutions span nearly every area of
your company may lawfully obtain access to this EPRI electricity generation, delivery, and use, including
Intellectual Property, you acknowledge that it is your health, safety, and environment. EPRIs members
obligation to consult with your companys legal counsel to represent over 90% of the electricity generated in the
determine whether this access is lawful. Although EPRI may United States. International participation represents
make available on a case-by-case basis an informal nearly 15% of EPRIs total research, development, and
assessment of the applicable U.S. export classification for demonstration program.
specific EPRI Intellectual Property, you and your company
acknowledge that this assessment is solely for informational TogetherShaping the Future of Electricity
purposes and not for reliance purposes. You and your
company acknowledge that it is still the obligation of you and
your company to make your own assessment of the applicable
U.S. export classification and ensure compliance accordingly.
You and your company understand and acknowledge your Effective December 6, 2006, this report has been made publicly available in accordance with
obligations to make a prompt report to EPRI and the Section 734.3(b)(3) and published in accordance with Section 734.7 of the U.S. Export
appropriate authorities regarding any access to or use of EPRI Administration Regulations. As a result of this publication, this report is subject to only copyright
Intellectual Property hereunder that may be in violation of
protection and does not require any license agreement from EPRI. This notice supersedes the
applicable U.S. or foreign export laws or regulations.
export control restrictions and any proprietary licensed material notices embedded in the
document prior to publication.

2006 Electric Power Research Institute (EPRI), Inc. All rights reserved. Program:
Electric Power Research Institute and EPRI are registered service marks of
the Electric Power Research Institute, Inc. Nuclear Power 1013249

ELECTRIC POWER RESEARCH INSTITUTE


3420 Hillview Avenue, Palo Alto, California 94304-1395 PO Box 10412, Palo Alto, California 94303-0813 USA
800.313.3774 650.855.2121 askepri@epri.com www.epri.com

You might also like