BASIC INSTRUMENTATION
Introduction:
The field of instrumentation includes the science and the art of measurement, control,
and process manipulation. Specifically, instrumentation is the technology of
creating, constructing, and maintaining the measuring and control devices and
systems that equip the manufacturing plants and research institutions.
So vital to todays expanding economy. Variables measured include temperature,
pressure, flow, liquid level, velocity, density, and many others.
2
Benefits of Electronics & Instrumentation in personal life & process
Industries.
Impact of Instrumentation in personal life increase Alertness,
Security, Time Saving etc
Alarming.
Fast response time
Increase process efficiency
Accurate Measurement & controls.
Data monitoring & historisation.
Graphical Presentation.
Fault diagnosis.
3
1. Measurement :
The art of measurement plays an important role in all branches of engineering and
science. Transducers and signal conditioners are the components of control loop,
which performs this task.
The transducer is defined as a device which, when actuated by one form of energy is
capable of converting into another form of energy. The transduction may be from
mechanical, electrical or optical to any other related form.
The signal conditioner can vary in complexity from a simple resistance network or
impedance matching network to complex multi stage amplifiers with or without
detectors demodulators and filters. Alternately, they are termed as signal modifier or
signal processors. The output signal may be usable analog or digital quantity.
4
Types of Signals:
Signals represent information. The representation may refer to the value (or) the
change in values of a physical dimension and may refer to transmission, processing
(or) storage of information.
An analog signal is a signal where each point in a continuous range of values of the
single parameter conveys different information.
Example:
1. Temperature range on thermometers
5
1.3 Digital signal :
A digital signal is a discrete, signal with a number of intervals of values of the signal
parameter.
Example:
1. Digital clock
2. Counting mechanism
2. Digital measuring device
A binary signal (two-point signal) is a single parameter signal with only two value
ranges.
It is therefore a signal conveying only two items of information.
E.g. On - Off
Yes- No
1 -0
6
2. Control :
In open loop control the transducer senses the physical parameter and it is converted to
usable signal by means of signal conditioner. The output of the signal conditioner can
be used for displaying or recording the physical quantity. It can be used to generate the
alarm condition but it does not influence the process on the basis of measured
parameter quantity.
ALARM
DISPLAY
7
2.2 Close loop control :
CV
SENSOR / PV
SIGNAL
CONDITIONER
CONTROLLER
CONTROLLED FEEDBACK
ELEMENT
8
CALIBRATION
Calibration must be performed periodically to test the validity of the performance of the
device or the system and requires the use of a standard for comparison of values.
9
ACCURACY
PRECISION
Precision is the closeness with which individual measurements are distributed about
their mean value. It refers to the degree of agreement of a set group of measurement
among themselves. It is equal to the mean value of the scatter of individual
measurements. It combines the uncertainty due to both random differences in results
in a number of measurement and the smallest readable increment in scale or chart
(given as the deviation of mean values).
10
ERROR
The output of a transducer is affected by the non-ideal behavior or the device, which
causes the indicated measurand value to deviate from the true value. The algebraic
difference between the indicated value and true value of the measurement and is
termed the error or the device. This error is usually expressed in per cent of the full-
scale output (% F.S.). The ratio of this error to the full-scale output is a measure of the
accuracy of the device.
ZERO DRIFT
Zero drift is the deviation observed in the instrument output with time from the initial
value when all the other measurement conditions are constant. This can be caused by
a change in component value due to variation in ambient conditions or due to aging.
SPAN
The range of the measurand variable for which an instrument is designed to measure
linearly is called the span. Sometimes it specifies the linear operating range of the
total scale.
11
PID Controlling:
PID stands for Proportional, Integral & Derivative. Controllers are designed to eliminate
the need for continuous operator attention. Controllers are used to automatically adjust
some variable to hold the measurement (or process variable) at the set-point. The set-
point is where you would like the measurement to be. Error is defined as the difference
between set-point and measurement.
(error) = (set-point) - (measurement) The variable being adjusted is called the
manipulated variable which usually is equal to the output of the controller. The output
of PID controllers will change in response to a change in measurement or set-point.
Manufacturers of PID controllers use different names to identify the three modes.
These equations show the relationships:
P Proportional Band = 100/gain
I Integral = 1/reset (units of time)
D Derivative = rate = pre-act (units of time)
12
Proportional Band
With proportional band, the controller output is proportional to the error or a change in
measurement (depending on the controller).
(controller output) = (error)*100/(proportional band)
With a proportional controller offset (deviation from set-point) is present. Increasing the
controller gain will make the loop go unstable. Integral action was included in controllers to
eliminate this offset.
Integral
With integral action, the controller output is proportional to the amount of time the error is
present. Integral action eliminates offset.
CONTROLLER OUTPUT = (1/INTEGRAL) (Integral of) e(t) d(t)
Notice that the offset (deviation from set-point) in the time response plots is now gone.
Integral action has eliminated the offset. The response is somewhat oscillatory and can be
stabilized some by adding derivative action.
Derivative
With derivative action, the controller output is proportional to the rate of change of the
measurement or error. The controller output is calculated by the rate of change of the
measurement with time.
CONTROLLER OUTPUT = dm/dt where m is the measurement at time t.
13
14
Various process parameter measurements and controlling :
a) Pressure
b) Level
c) Temperature
d) Flow
e) Ph & Conductivity
f) Weighing
h) Drives
15
Various Instruments used for process parameter measurements and controlling :
a) Pressure :
16
PRESSURE GAUGE
17
PRESSURE TRANSMITTER
18
PRESSURE TRANSMITTER
19
PRESSURE SWITCH
20
b) Level :
21
LEVEL GAUGE
22
LEVEL GAUGE
23
LEVEL SWITCH
24
LEVEL TRANSMITTER
25
c) Temperature :
Hotness or coldness measure of any substance. Also known as degree
of heat or quantity of heat.
Measuring Units:
Fahrenheit ( 0F ) : Introduced in 1709 by German philosopher
Fahrenheit. Melting point of ice is of 320F & boiling point of it is 212 0F.
0F = 9/5 X 0C + 32
26
Thermocouple:
Working Principle of Thermocouple is thermoelectric effect. If two
dissimilar metals are joined together so as to form a closed circuit,
there will be two junctions where they meet each other. If one of
these junctions is heated, then current will flow in the circuit. It can
be measured by electronic instrument. Current will flow
continuously until both temperatures become equal
Practical diagram
Indicator
27
Thermocouple details :-
28
Resistance temperature detector: (RTD)
The electrical resistance of a conductor changes as its temp. varies. The magnitude
of this changed with respect to a 1 deg.C change in temp. is known as the Temp.
Co-efficient. For Platinum it is 0.00385.
Rt = Ro ( 1+ T )
Rt = Resistance in ohms at Temperature T
Ro = Resistance in ohms at a reference temperature
= Temp. Co-efficient of resistance
29
Difference between RTD and Thermocouple :-
SR RTD THERMOCOUPLE
1 Low Range (-200 Deg. C to 600 High Range (-270 Deg. C to 2800 Deg. C)
Deg. C)
4 Below 33 Deg. C of span Not possible because ref. Junction is the ambient
measurement is possible. temp.
5 Parallel application not possible using It is possible.
one sensor.
30
d) FLOW :
Introduction :
Measurement of flow rate and quantity of the oldest of all measurements of process
variables in the field of instrumentation. Without flow measurements, plant
material balancing, quality control and even the operation of any continuous
process would be almost impossible.
Flow measurements are made both for fluids and solids.
1. Variable Head
2. Magnetic type
3. Turbine type
4. Variable area
5. Vortex flow meter
6. Ultrasonic flow meters
31
Vortex Flow Meter
32
e) PH :
1. Introduction :
A pH meter measures pH of solution and identify whether it is Acidic or Basic in nature.
Solution having pH more than 7 are Basic in nature and less than 7 are Acidic in nature.
Solutions having 7 pH is neutral.
Conductivity :
The unit of conductance , the reciprocal of OHM, is SIEMNs (s).It express the
measurement of the mobility or velocity of ions in an electrolyte under an imposed
electric field. Value of conductance, reported for one gram equivalent weight of the
conducting ion are termed equivalent conductivity..
33
f) Weighing:
To weigh an object means to measures the force of gravity on its mass at a particular
location.
W = mg
Where, W= weight of the object.
m = mass.
g = acceleration due to gravity.
34
g) Final Control Elements :
Control valves
I/P converters
Solenoid valves
35
Control Valve Classification
36
Control Valve
37
Butterfly Valve Globe Valve
38
Ball Valve
39
I/P Converters
40
41
h) VFD :
What is VFD :
Variable Frequency Drives vary the speed of an AC motor by varying the
frequency to the motor.
Benefits of VFDs
Step less speed can be achieved which is required in process control.
Energy Saving
Improvement in productivity.
Protection to motor from over Current. Life of equipments will increase.
42
43
i) PLC: PROGRAMMABLE LOGIC CONTROLLER
Introduction :
Programmable logic controllers are microprocessor based controller devices generally
used for processing digital Inputs/Output and digital data. Modern PLCs have the
enhanced communication capabilities and ability to process the Analogue signals also.
It is generally used for performing Arithmetic & logical operations, Sequential
operations, interlocks and Motion control.
PLC Diagram:
CPU PS MODULES
CHASIS
44
CPU
SLC 5/04 CPU
RUN FORCE
FLT DH+
BATT RS232
*
*
*
45
Functions / Operations:
3. Download: Transfer or copy of program 4. Upload: Copy & Saved the program
from PC to Processor. from processor to PC.
( Harddisk )
PC PLC / SLC
PC PLC / SLC
46
Addressing & Processor operation:
I / O addressing: I I - Input
or : e. s / b O - Output
: - Element Deliminator
E - Slot Number
. - Word Deliminator
s - Word Number
/ - Bit Deliminator
b - Terminal Number
Scan Time:
Scan Time = I /O scan + Program scan.
If program is small then scan time less, it depends on program.
Processor
Signal Flow:
Input Device Data Files Control
I : 1/0 Element
I : 1/0 O : 2/0
I : 1/0 O : 2/0
47
Operating Cycle:
Input / Output
Scan
Program Scan
Overhead
Process
Communication
48
PLC Language:
Ladder Diagram:
Symbol
Address Power Rail
PUSH BUTTON
I : 1/0 O : 2/0
Rung
Branch
O : 2/1
Instructions
49
CSF: Q 4.0
I 1.0
& =
I 1.1
Statement List :
: A I 1.0 Where, A is logical operation
: A I 1.1 I is Operand ID
: = Q 4.0 0.1 is parameter
: BE
50
DISTRIBUTED CONTROL SYSTEM ( DCS )
Introduction
A system that controls / functions throughout the plant .
Many processors handle the control / management functions .
Use a common data bus for communication .
US 1 US 2 US 3 US 4 US 5
AM AM HM 12
1 2 3 4 5 13 15
LCN - A
LCN - B
31 NIM NIM 32
NIM NIM
LCNA
AP 3/4
AP
14 MM
PRINT
ER
51
PHD
DCS Distributed Control System
52
PLC Programmable Logic Controller
Software limitations.
No Graphical view Directly.
Report or Trending facility can be can be availed by using external PC.
No direct alarming.
Modification / Addition / Deletion online not possible.
53
Important points for Selection of Instruments:
Application
Process Detail
Operating conditions e.g. Pressure , Temperature
Type of Instruments
Range
Size
Area of Operation
MOC
Installation
Make
Reliability
Cost
54
Dos & Dont for Instruments:
Dos :
Proper Inputs for selection of instrument.
Installation as per Process & Instrument standards.
Predictions, observations & Immediate actions.
Proper protections, cares.
Proper pneumatic & electrical connections.
Proper start ups & shutdowns
Maintain Basic conditions.
Inform to Instrument dept. about any abnormality in field Instrument.
Dont :
Avoid damping due to process variations.
Dont use instrument above the span.
55
56