You are on page 1of 184

1

Introduction
What is Pvti used for ?
Lunching Pvti
The Main Panel
Define Components
Characterisation of Plus Fraction
The Fluid Model
Samples In Pvti
Phase Plot
Exercises

2
Fluid Properties Estimation
Creating a Fluid System
Simulating Experiments
Regression
Exporting Eclipse Pvt Table

3
Fluid Flow Simulation Data

Grid & Geometry Property Model

PVT Model Geocellular Model SCAL Model

Eclipse Model
Production History Well Test
4
Different Sections In a Eclipse Data File

5
Pvti is a compositional pvt
equation of state based
program used for
characterizing a set of fluid
samples for use in our
Eclipse simulators.
We need Pvti because it is
vital that we have a realistic
physical model of our
reservoir fluid samples
before we try to use them in
a reservoir simulation.

6

Require knowledge of fluid behavior in reservoir, well and at surface
Over a wide range of pressures, temperatures and compositions

7
Need to predict:
Composition of well stream v.s. time
Completion design (wellbore liquids)
Gas injection or re-injection
Specification of injected gas- how much C3, 4, 5s to
leave in
separator configuration and conditions
Miscibility effects

8
To match an Equation of State to
observations
This is done to compensate for the inability to
measure directly all the things we need to know
about the hydrocarbons
To Create
Black-Oil PVT tables for a Black Oil model
Compositional PVT parameters for a
Compositional Model

9
The Main panel
Systems: Define Fluids and
Samples
Simulate: Experiments and
Observations
Regress : Match EoS
Export : Results to Simulators

10
11
12
13
14
Edit
Fundamentals
Fluid Model
Samples
Properties Estimation
Experiments
Observation

15
16
Edit
Fundamentals
Fluid Model
Samples
Properties Estimation
Experiments
Observation

17
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients
Split
Group

18
An Equation of State (EOS) is
an analytic expression relating
pressure to volume and
temperature
Best method for handling large
amounts of PVT data
Efficient and versatile means
of expressing thermodynamic
functions in terms of PVT data
None completely satisfactory
for all scientific and
engineering applications

19
20
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients
Split
Group

21
22
Library Component
User Component
Characterized Component

23
24
25
26
If you use characterization
components, you must generally
specify at least two out of the
following:
Molecular weight Mw
Specific gravity , Sg
Normal boiling point temperature
, Tb
Watson characterization factor ,
Kw

27
Two strings which specify the
characterization procedure
required for:
Critical properties.
Kessler-Lee (K), Cavett (C),
Riazi-Daubert (R), Winn (W) or
Pedersen (P)
Acentric factor.
Kessler-Lee (K), Edmister (E),
Thompson (T) or Pedersen (P).

28
Properties increasing with
increasing molecular weight
Tc Critical Temperature
Tb Normal Boiling Point
Vc Critical Volume
Acentric Factor
o Liquid Density
Pa Parachor

29
Properties decreasing with
increasing molecular weight
Pc Critical Pressure
Zc Critical Z-Factor

Having defined our


components and pseudo-
components, we can define
what our sample is made of.

30
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients
Split
Group

31
Strictly, binary interaction
coefficients are interpreted as
accounting for polar forces between
pairs of molecules.
Many authors have suggested that
binaries are the obvious Equation of
State parameter to adjust to match
Equation of State to laboratory
results, especially the Methane to
plus-fraction binary. However,
Pedersen et al., have shown that
this is problematic.

32
33
Katz and Firzoobadi
Experimentally determined for Non-Hyd:Hyd
Hyd:Hyd all zero except between C1 and CN+

kC1-CN+=0.14 - 0.06

Cheuh-Prausnitz
Theoretical consideration

2(V V )1/ 6
B

A1 1/ 3
c ,i c , j
ki , j
Vc ,i Vc1,/j3

34
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients
Split
Group

35
The volume shift corrections applied to the
three-parameter PR3 and SRK3 equations
of state assume that the mis-match in
predicted and measured liquid density at
some reference conditions on a component-
by-component basis can be used to correct
volumes at all other pressures and
temperatures. In an attempt to account for
the known temperature dependence, two
methods are available for modifying the
volume shifts.

36
No Temperature Dependence
Temperature Dependence
Linear Expansion Only
Polynomial correlations

37
38
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients

Split
Group

39
Insufficient description of heavier
hydrocarbons reduces the accuracy
of PVT predictions (Whitson C.H.,
SPEJ, p. 683, Aug. 1983)
Condensates and Volatile Oils are
particularly sensitive to plus fraction
composition and properties
Laboratories tend to give very limited
analysis to the plus fraction, i.e., MN+,
N+

40
The plus fraction often has an
importance that appears to far
outweigh its relatively
small mole fraction of a fluid sample.
In particular, saturation pressure
calculations can be extremely
sensitive to the mole fraction and
properties of the plus fraction. More
accurate predictions requiring less
regression of equation of state
parameters can be achieved if a
thorough description of the plus
fraction can be made.

41
This menu allows for the
automatic splitting of the plus
fraction in to a required
number of sub fraction for
subsequent use in a large
regression or for output to a
compositional simulator such
as one in Eclipse.
There are four methods
available from this option for
splitting the plus fraction ,
which must be the last
component :

42
Constant mole fraction
splitting (CMF)
Whitson
Multi feed split, or
semi continuous
thermodynamic
splitting

43
Equation of State
Components
Binary Interaction Coefficients
Volume Shifts
Thermal Properties
LBC Viscosity Coefficients

Split
Group

44
This menu allows for the automatic
grouping of the sub fraction for
subsequent use in a large regression
or for out put to a compositional
simulator such as the one in Eclipse.
There are three methods available
from this option for grouping the
components :
Mole fraction
Molecular weight
Mixing Rule

45
Compositional simulator
uses same EOS model as
PVTi
Flash calculations can take
50% of simulation time
Reduce number of
equations reduce
number of components

46
Basis for grouping
similar properties, eg MW
same log(K) versus p trend
insensitivity of experiments to trial
grouping

Obvious candidates
iC4 and nC4 C4
iC5 and nC5 C5

Add N2 to CH4, CO2 to C2H6 (at low


concentrations)

47
Edit
Fundamentals
Fluid Model
Samples
Properties Estimation
Experiments
Observation

48
49
50
51
View
Samples
Observation
Library

52
53
Finger plot give an idea of the
nature that is condensate or
volatile oil, of a given fluid sample
providing a reasonable split of the
heptanes plus, then condensate
typically has straight line or down
tuning, slope proceeding towards
the heavier fractions whilst a
volatile oil has an upturning ,slope
as it usually contains more heavy
fraction

54
55
56
Utilities / Units
Edit / Fundamentals
Edit / Fluid Model
Equation of state

57
This Exercise describes how to use PVTi for Fluid Properties Estimation.Fluid properties estimation
can provide quick-look PVT tables at the well site.A saturation pressure (bubble or dew-point)
together with a reservoir composition are sufficient inputs to provide a quick-look simulation, giving
an initial estimation of fluid properties in advance of a full fluid analysis in the lab.After completing

this Exercise you should be able to use PVTi as a simulation tool for fluid properties estimation.

CO2 0.91
N2 0.16
C1 36.47 Unit :Field
C2 9.67 Temp Unit : Fahrenheit
C3 6.95
Percentage
IC4 1.44
NC4 3.93
Gage Pressure
IC5 1.44 Pb = 2516.7 psig
NC5 1.41
Temp = 220 F
C6 4.33
C7+ 33.29

Mw C7+ 218
Spg C7+ 0.8515

58
Split The C7+ Component to 4
Components By :
Whitson Method
Draw the phase and finger plot
Compare the Phase Plots

59
Edit
Samples
Properties Estimation
Experiments
Exercises

60
61
62
63
64
65
Define Sample 1 (ZI) as
Separator Oil
Define Sample 2 (Gas) as
Separator Gas
Mixing Type By : Gas/Oil Ratio
New Sample Name:Recomb
System Temp: 205 F
System Press: 2000 Psia

66
67
Single Point
Pressure Depletion
Injection Study
Separators

68
69
Feed this container with N moles of fluid -
composition CO2 N2 C1 C 2-3C 4-6 C 7-10 C 11-15
C 16-20 C 20+ (know Zi mole fraction feed)

Flash: Determine amount, properties


and composition of the vapor and
liquid at EQUILIBRIUM

Temperature and
Pressure Set

70
K-values = Equilibrium Constants

V yi
yi
Ki
xi L xi

71
Specify temperature
and feed composition
of OIL
PVTi returns pressure
where phase transition
occurs.

72
Specify temperature
and feed composition
of GAS
PVTi returns pressure
where phase transition
occurs.

73
Definition: The intensive
properties of the vapor
and liquid become equal
Intensive properties -
independent of the
amount of component
Extensive properties -
dependent on the amount
of substance in the
system, e.g. heat content,
volume internal energy.

74
75
76
Simulation Section
Defining Fluid System
of GAS5
MAKE DEW POINT
CALCULATION

77
78
Specify a temperature and a
series of pressures
Pick: OIL, GAS or SIN (true
one-phase system, such as
dry gas above the
cricondontherm)
Saturation volume will be
used as a normalization
volume

79
At p > psat there are no compositional changes and
CVD and DL are equivalent to CCE

Vapor Vapor
Cell
Volume at
liquid
liquid Bubble Point

Liquid Liquid

p>pb pb p<pb p<<pb

80
Specify a temperature and a
series of pressures.
Applied to liquid/oil systems only
All gas is removed at each
pressure step
Last pressure step will be a
reduction to standard conditions -
automatic.

81
Schematic Diagram of
Differential Liberation Withdrawn
Gas
Withdrawn
Gas

Vapor
Vapor
Cell
Liquid
Volume at
Liquid Liquid Liquid Liquid Bubble Point

p>pbub pbub p<pbub p<<pbub

82
Separator tests are conducted to determine
the changes in the volumetric
behavior of the reservoir fluid as the fluid
passes through the separator
(or separators) and then into the stock tank.
The resulting volumetric
behavior is influenced to a large extent by the
operating conditions, i.e.,
pressures and temperatures, of the surface
separation facilities. The primary
objective of conducting separator tests,
therefore, is to provide the Liquid Liquid
essential laboratory information necessary for
determining the optimum
surface separation conditions, which in turn will pbub
maximize the stock-tank p>pbub
oil production.

83
Separator Separator Gas/Oil Ratio Formation Molar fraction Density Density
Pressure Temperature Volume to Liquid of Liquid of Vapor
o
Barsa C Factor Stream Fraction Fraction

50 50 91.46 0.642 697.41 44.614

to

1.0132 30 105.78 2.0441 0.344 787.22 1.623

Cumulative for 232.38 2.0441 0.344 795.25 1.260


Separator Train

1.0132 15.5556 240.81 2.0925 0.336 797.48 1.280

25 25 133.89 0.583 731.70 22.646

to

1.0132 5 53.23 1.8629 0.418 783.37 1.612

Cumulative for 187.86 1.8629 0.418 777.25 1.064


Separator Train

84
85
86
87
88
89
90
Cannot predict viscosities from EOS:
phase flow property
Two most widely used correlations
Lohrenz-Bray-Clark (LBC)
Pedersen et al
LBC OK for gases and volatile oils, very
poor for heavier oils
Pedersen better for gases and oils, but
not good for heavy oils (presence of
asphaltenes)

91
92
Based on Corresponding States Method
(CSM)
A group of substances obey CSM if functional
dependence of reduced quantity on other
reduced quantities is the same for all
components in the group
Pedersen
mr = f(Tr, Pr)

Alternative Ely and Hanley


mr = f(Tr, r)

93
Viscosity a parameterized function of reduced
density

r
c

where critical density


1
1 N

c xi Vc ,i
Vc i 1
To give
a1 a2 r a3 r a4 r a5 r
2 3 4

94
95
A Reliable Prediction of The
Pressure Performance of a
Gas Condensate Reservoir is
Necessary in Determining
Reserves And Evaluating Field
Separation Methods.

96
Specify a temperature
(below cricondotherm) and
a series of pressures
Applies to both oil and
condensate systems
Vapor removed to restore
cell to original volume
Relative volume reported is
the fraction of the cell filled
with liquid after the gas is
removed

97
Withdrawn
Gas
Withdrawn
Gas

Vapor Vapor
Cell
Vapor Volume at
Vapor Dew Point
Vapor
Liquid Liquid

p>pdew pdew p<pdew p<<pdew

98
It should be performed on all
Condensates and volatile oils as
these are the fluids which are going
to undergo the greatest
compositional changes if the
reservoir pressure is allowed to drop
below the saturation pressure.
As the pressure drops below the
bubble point/dew point pressure, the
following calculations and
procedures are taken:

99
Simulation Section
Defining Fluid System of GAS5
Simulating Dew Point Pressure
Calculation
Simulating CCE Experiments
Simulating CVD Experiments
Observed Data:Vap-Z Factor-
Liquid sat Moles Recoverd
Plotting Results

100
Simulation Section
Defining Fluid System of
GAS5
Split Heavy component to 3
,Using Multi Feed Method.
Simulating CCE Experiments
Simulating CVD Experiments
Observed Data:Vap-Z Factor-
Liquid sat Moles Recovered
Plotting Results

101
102
103
Why Regress EOS parameters?
Incomplete fluid description
Limitations of cubic EOS

Problems of regression
Multi-variable
Non-linear

104
Check measured data for
consistency and quality
Compositions sum to 100%?
Pressure-dependent data: correct
trends?
Material balance on CVD?
Property definitions?
Consistent units?
Plus fraction description?
EOS: Use three-parameter
model - extra degree of
freedom in si (Volume Shift
Parameter)

105
Vary properties of poorly
defined components, i.e., plus
fraction(s)
Choose as few properties as
possible
Bounding Rms or
Variables limits
Redundancy in variable set: trial and
error to find optimum set or
sensitivity matrix Aij = ri/xj

Ensure variable monotonicity

106
(Tc, pc), or Omegas of plus
fraction(s): saturation pressure,
liquid dropout, etc.
Volume shift: Z-factors, densities,
etc.
Zc or Vc for LBC viscosity
Consider
Experiment set
Observation set and weights
Variable set and limits

107
Dont Use Library Component As
Regression Parameter
Pc, Tc & w of any Non Library
Component
Pc , Tc & w of any Component With
Molecular Weight of C7 or Heavier
OmegA & OmeagB of Any
Component With Molecular weight of
C7 or Heavier

108
Set of variables:

x ( x1 , x2 ,..., xN ) T

Define Residuals:

ri ( x) yiobs yicalc ( x) (i 1,2,..., M )


where M < N
then, Rms Error

1 M 2
f ( x) ri ( x)
2 i 1

109
110
Experiments and observations
Laboratory Measurements
CCE
CVD
DL
Separator Test

Regression: which variables?


When? How?
Regression weights

111
112
113
114
Regression
Using Fluid Model of Exercise-7
Fitting an EoS by regression
Regression using the normal
Variables
Plot The Results

115
Oil based muds are widely used in offshore drilling
applications. Of concern however is the resulting
contamination associated with obtaining high quality samples
of formation hydrocarbons. The filtrate of oil based muds is
highly soluble in formation hydrocarbon fluids, therefore, any
contamination of the sample with oil based mud filtrate can
significantly affect the composition and phase behavior of the
formation fluids. The reservoir fluid samples for PVT tests can
either be collected by bottom hole and/or surface sampling
techniques as and when appropriate. During the drilling
process, due to over-balance pressure in mud column, mud
filtrate invades the formation. If an oil-based mud is used in the
drilling, it can cause major difficulties in collecting high quality
formation fluid samples. As the filtrate of oil-based
drilling mud is miscible with the formation fluid, it could
significantly alter the composition and phase behavior of the
reservoir fluid. Even the presence of small amount of oil-based
filtrate in the collected sample, could significantly affect the
PVT properties of formation fluid.

116
Oil based muds are in widespread
use and often contaminate PVT
samples taken at the well site.
PVTi offers two methods for
cleaning oil based muds :
Removing oil based mud
contamination by skimming
method.
Removing oil based mud
contamination by subtraction
method.

117
118
119
120
MW C25+ =400
SPG =.89857

121
Mud composition

122
123
One objective of PVT Analysis
Produce data for simulation
Type of model to use
Blackoil Model
Compositional
All assume that EOS has been
tuned to reliable measured data

124
Different Sections In a Eclipse Data File

125
126
127
128
129
130
131
132
133
134
135
136
137
Region 1

Region 2

138
PB = 2516.7 PSIG
Temp = 220 F

139
140
141
Exporting
Eclipse 100 PVT
tables
Changing the unit
system
Generating Eclipse
100 PVT tables

142
Exporting Eclipse 100 PVT
tables
Changing the unit
system
Generating Eclipse 100
PVT tables

143
144
When can you use a
Black-Oil model?

When should you use


a compositional
Model?

145
PVTi has several simulations
available for investigating gas
injection processes.The three
that correspond closely to
laboratory experiments are:
Swelling Test
Vaporization Test
Multiple Contact Test

146
147
148
149
150
151
152
Moles of Injected
Gas Sat.Press

Injected Gas : CO2


Temp : 302 F

153
Moles of Injected Relative vol.
Gas

154
155
An oil-gas displacement is immiscible if
the oil and gas segregate into separate
phases.
Oil-gas relative permeabilities and
capillary pressures are used.

A displacement is miscible if the


mixture of oil and gas forms a single
hydrocarbon phase.
Oil-gas relative permeabilities and
capillary pressures are not needed.

156
Under normal conditions, oil & gas
reservoir fluids form distinct, immiscible
phases
Immiscible phases are separated by an
interface
associated with inter-facial tension (IFT)
when IFT=0, fluids mix => MISCIBILITY
residual oil saturation to gas (and water)
directly proportional to IFT
miscible displacement characterized by
low/zero residual oil saturations

157
Establishment of miscibility
depends on
pressure (MMP)
fluid system compositions
Miscibility normally
determined by laboratory
measurement
Miscibility difficult to predict
analytically
complex phase behavior
derivation of surface tension

158
Three basic types of
miscible process
first-contact miscibility
condensing-gas drive
vaporizing-gas drive

159
Example Oil: C1 - 31% Injection gas: C1
nC4 - 55%
C10 - 14%
Pressure/Composition Diagram
4000 for Mixtures of C1 with C1/nC4/C10 Oil.

Pressure Plait point Cricondenbar (3250 psig)


Psia

Bubble Pts
Dew pts

0
0 100
50
Volume % Methane

160
Rule 1:
For 1st Contact Miscible -
Pressure of Displacement
must be above
Cricondenbar

161
Pressure > MMP
All points between solvent and
reservoir oil lie in single phase
region
Need high concentrations of
solvent - expensive

162
Injection gas is enriched with
intermediate components such as:
C2, C3, C4 etc
Mechanism:
Phase transfer of intermediate MW hydrocarbons
from the injected gas into the oil. Some of the gas
Condenses into the oil.
The reservoir oil becomes so enriched with these
materials that miscibility results between the
injection gas and the enriched oil.

163
Injection Gas Injection Gas Injection Gas Injection Gas

oil

Equilibrium Oil Transferred to Next Cell

Condensing Gas Drive

164
Mixing 1: Injection gas with Reservoir Oil
Mixture M1 splits into L1 and V1
(liquid and Vapor)
Mixing 2: Injection gas with Liquid L1
Mixture M2 splits into L2 and V2 V1
Mixing 3: Injection gas with Liquid L2 V2
Mixture M3 splits into L3 and V3 V3
Mixing 4: Injection gas with Liquid L3 injection gas
Mixture M4 splits into L4 and V4 G
V4
The enriched Liquid Li position moves toward
the Plait Point until a line connecting the M M4
M2 3
injection gas and the enriched liquid lies M1 Plait Point
only in the single phase region.

L4
L1 L2 L3
reservoir oil
o

extension of critical tie line

165
Miscibility developed at the gas compositions with NO
trailing edge of the injection multiple contact miscibility

gas

gas compositions with


multiple contact miscibility

line from reservoir oil tangent


to 2 phase envelope

O
gas compositions with
reservoir oil first contact miscibility

extension of critical tie line

166
Pressure < MMP
Solvent and oil not miscible
initially
Solvent components transfer to
liquid oil phase
Repeated contact between oil
and solvent moves system
towards plait (critical) point
(dynamic miscibility)

167
For systems with oil composition
to left of tie line, solvent
composition must lie to right
Field behavior is more
complicated
continuous, not batch, contact
both phases flow
actual phase behavior more complicated,
especially near plait point

168
169
As P increases the two phase region becomes
smaller. At some point gas A is to the right of the
limiting tie line and MCM develops.

95-98% miscible
X X X X X
X
X
X
Oil Recovery X
% X Minimum Miscibility Pressure
(MMP)
P

Results from slim tube displacements at various


pressures

170
171
172
Injection Gas - Lean Gas, C1,
CO2, N2

For vaporizing gas drive -


multiple contact miscibility
Mechanism: Intermediate
hydrocarbon components in the
oil vaporize to enrich the gas.
As the leading edge of the gas
slug becomes sufficiently
enriched, it becomes miscible
with the reservoir oil.

173
Injection Gas
Equilibrium Gas Transferred to Next Cell

oil oil oil oil oil oil

174
injection gas
Mixing 1: Injection gas with Reservoir Oil G
Mixture M1 splits into L1 and V1 V1
(liquid and Vapor)
Mixing 2: Gas Mix V1 with reservoir oil M1 o
V2
Mixture M2 splits into L2 and V2 M2
o V3
Mixing 3: Gas Mix V2 with reservoir oil
Mixture M3 splits into L3 and V3 M3
o V4
Mixing 4: Gas Mix V3 with reservoir oil V5
Mixture M4 splits into L4 and V4 M4 o
o
Mixing 5: Gas Mix V4 with reservoir oil
Mixture M5 splits into L5 and V5 M5

The enriched Gas Vi position L3 L4


L1 L2
moves toward the Plait Point L5
until a line connecting the
enriched gas and the
reservoir oil lies
only in the single
phase region.

o reservoir oil

175
injection gas
Miscibility developed at the G
leading edge of the injection
gas

For MCM in a Vaporizing Gas Drive


The Reservoir Oil composition MUST
lie to the right of the limiting tie line

176
177
178
179
180
Typical uses of Black-Oil and
Compositional:
Black-Oil: Pressure Depletion,
Heavy to medium oils
Compositional: Gas injection,
Miscibility,Near-critical fluids,
Condensates

181
Reservoir compositions xi, yi
from depletion experiment, i.e.,
CVD or DL
Whitson and Torp: flash liquid
and vapour through separators
Blackoil properties ratio of
reservoir/separator volumes, etc.
Coats: vapour as Whitson and
Torp
Liquid volumes by mass conservation
Satisfies reservoir oil density

182
First Contact Miscibility Pressure
Experiment
Specify a temperature and two named samples
Calculates the lowest pressure at which the samples
will be directly miscible (always one phase) in all
proportions.

183
Taking Exercise-11
Add First Contact & Multiple
Contact Miscibility Experiments
Compare The Results.

184