Maintenance Procedures

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-1


Objectives

This section gives an overview of maintenance features of OMC-R. It


describes briefly:
"Confidential information -- may not be copied or disclosed without permission".

OMC-R monitoring and defense principles: taking the appropriate


action corresponding to the detected fault or system malfunction.

OMC-R operating control procedures: diagnosing certain OMC-R


states (both hardware and software).

OMC-R maintenance procedures: corresponding to maintenance


procedure sheets.

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-2


Contents

OMC-R Monitoring and Defense Principles


"Confidential information -- may not be copied or disclosed without permission".

OMC-R Operating Control Procedures

E4XXX+A5000 (or E4002+ SSAs) Maintenance

OMC-R Configuration Check

OMC-R Database Check

OMC-R Database Re-installation

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-3


OMC-R Monitoring and Defense Principles

Via Asynchronous link


or Ethernet or X.25 OSI layers
(Q3)
"Confidential information -- may not be copied or disclosed without permission".

Monitoring
OMC-R
tasks
Diagnosis

Back up
Defense
Table of server
defense
thresholds
Workstations

Action

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-4


"Confidential information -- may not be copied or disclosed without permission".

OMC-R Operating Control Procedures

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-5


OMC-R Operating Control Procedures

Hardware diagnosis: LED's on OMC-R hardware elements


"Confidential information -- may not be copied or disclosed without permission".

Blackbox
Black box
Server

112 AliCEC104106103107142 RC
Pwr ECC

Samatrans
Station

2242
STN
Menu

1
Modem

N
RL2
TB2
L3
B3
Auto
X Terminal

Prog
PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-6
OMC-R Operating Control Procedures
Software Diagnosis

System trace file: /var/adm/messages

OMC-R software trace file: /CMN/base/diagnostic/omc_logfile


"Confidential information -- may not be copied or disclosed without permission".

Tests initialization diagnosis: /MD/diagnostic/diag_xxxx


/OMC/diagnostic/diag_xxxx
/CMN/diagnostic/diag_xxxx

Defence files: /OMC/data/defence/cf_def_log.YYYYMMDD


/MD/data/defence/cf_def_log.YYYYMMDD

Defence action file: /CMN/base/diagnostic/diag_defence

Data operation diagnosis: /usr/sybase/install/errorlog_syb

Control of the OMC-R application state (using background menu)

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-7


OMC-R Operating Control Procedures
Control the OMC-R State
Manager/MD-R server status <main server name>
Partition/of 25 159 KB (58% used)
Partition/tmp of 356 712 KB (1% used)
Partition/MD/restored/obs of 962 582 KB (1% used)
"Confidential information -- may not be copied or disclosed without permission".

Partition/MD/notif of 556 631 KB (1% used)


Partition/MD/restored/trace_function of 452 703 KB (1% used)
Partition/MD/restored/notif of 269 791 KB (1% used)
Partition/OMC/base of 156 991 KB (65% used)
Partition/MD/base of 122 695 KB (61% used)
Partition/MD/ssn of 288 855 KB (1% used)
Partition/OMC/data of 1 948 773 KB (27% used)
Partition/MD/obs of 1 948 773 KB (1% used)
SYBASE server is running on this server
Manager/MD-R is operational
All tasks are running (60 task(s))
The Manager MD-R server isnt fitted with SSA

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-8


E4xxx+A5000 (or E4002+SSAs) Maintenance (1/3)

E4XXX E4XXX
Power supply

Mirroring link
A5000+E4000
restart
"Confidential information -- may not be copied or disclosed without permission".

A5000 Check Local


partitions

SSA token
LCD Display
Sun

A0 B0 B1 A1 StorEdge A5000
Mirror state
0 0
Mount A5000
2 2 partitions
4 4
Umounting
6 6 partitions
8 8

10 10 Reboot
c ok

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-9


E4xxx+A5000 (or E4002+SSAs) Maintenance (2/3)

Power supply

SSA+E4000
Mirroring link restart
"Confidential information -- may not be copied or disclosed without permission".

Check Local
partitions

SSA token

SSA SSA Mirror state

Mount SSA
LCD Display partitions

A B Umounting
partitions

Reboot

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-10


E4xxx+A5000 (or E4002+SSAs) Maintenance (3/3)
These tools have to be run under croot when application is running:

rebuildmirror.sh c<x> synchronizes both SSA disk array devices or


"Confidential information -- may not be copied or disclosed without permission".

each A5000 block disk array device

repair_db.sh c<x>t<y>d<z>s<?> repair corrupted replicas

repair.sh <cxtydz> Allows to change a SSA disk without stopping OMC-R


repair_A5000.sh <cxtydz> Allows to change a A5000 disk without stopping OMC-R

stat_db.sh Displays the state of the replicas

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-11


OMC-R Configuration Check

Open an Unix window using background menu


"Confidential information -- may not be copied or disclosed without permission".

Log in as croot

Run the tool command ds_check.sh -Dcheck_grp

(Use ds_check.sh -h to list check_grp values)

results screen output


log file in /var/local/oam
filename=ds_check_db_log_hhmmss.yyyymmdd

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-12


OMC-R Database Check

Stop OMC-R application - Using MMI interface


- Using /home/omc/bin/appstop
"Confidential information -- may not be copied or disclosed without permission".

Open an Unix window using background menu

Log in as omc

Run the tool command ds_check_db.sh -NoFix or -Fix

Change the directory cd /var/local/oam

Read the result file in ds_check_db_log_hhmmss.yyyymmdd

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-13


OMC-R Database Re-installation

If both servers detect a database problem,


the following operations have to be performed:
"Confidential information -- may not be copied or disclosed without permission".

Removing of the files indicating that a switchover has been performed

Creation of the virgin databases

Restoration of an OMC-R BDE on the active server

Configuration of the OMC-R application on both servers

Restart of the OMC-R application on passive and active servers

See System Global Restoration Procedure in the appendix section

PE/TRD/CN/0303 12.02/EN March, 2000 Maintenance Procedures 8-14


"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Student Notes

Maintenance Procedures
8-15
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Student Notes

Maintenance Procedures
8-16