Fault Isolation and Rectification Steps
RF Cable verification
NOTE: The TRX Test can be used to find any badly damaged RF cables but may not
identify all the damaged cables that can lead to the TRX/BCF restart issue. It may
also be necessary to perform the faulty cable isolation test.
The TRX test can be run for each individual TRX installed at the site.
Before this:-
Disable BB or AHOP from the sector under test.
The power for the sector should be PMAX=0 (set at BSC).
A faulty cable may give failed TRX test results with one of the following reasons:-
> Low Power in Abis1- Air3 Loop
> RF cables not connected.
* A snapshot of follows.
* A document is attached describing the Tests from BSC for different configurations.
The cable is an RG 400 cable with QMA Male type connectors at both ends. Cable codes:
994931b RA QMA RF CABLE ASSEMBLY 172 MM
994933b RA QMA RF CABLE ASSEMBLY 275 MM