Water
Vapor Reflux
Wet
Gas Expander
Chill-Down
Feed Gas Slug Catcher Dehydration
Heat Exchange
II
DEETHANIZER
Recovered
Wet Vapors
HP Condensate Cond
Flash NGL
Vapors Reboiler
Vapor
Recovery Stabilizer
I Vapors
190 psig
FROM FIELD 110oF 2nd 1st F
GATHERING 1,300 psig 94oF PIC
5.7 MMscfd
S
INLET GAS
PIC 107oF
95oF 3.4 MMscfd
1,300 psig 175 psig
LIC
SLUG CATCHER
PIC 485 psig
STABILIZER
WET HP CONDENSATE FIC 250 psig 235 psig
F
500 psig F
S
CONDENSATE
STABILIZER 14,860 B/D
PRODUCT COOLER TO STORAGE
DESHIDRATACION DE GAS Y REGENERACION
TAMIZ MOLECULAR (TREN #1 O #2)
INLET FILTER GLYCOL INLET GAS DEHYDRATORS Adsorb: 24 Hrs (1,265 psig)
SEPARATOR CONTACTOR COALESCER FILTER (MOLE SEIVE BEDS) Regen: 12 Hrs (450 psig)
TRAIN #1 <2psi (Clean)
95oF
10psi (Dirty)
220 MMscfd PDI
WET GAS <2psi (Clean)
10psi (Dirty) 30 gpm
FROM SLUG PDI
CATCHER FI
LC Adsorption Adsorption
5-8 psi
LC
PDI
LC LC
TO CONDENSATE LC
SEPARATOR Normally Regen
No Flow 450oF
WET COND
Normally No Flow
5 MMscfd
FIC
REGEN GAS
470 psig 5 gpm
FIC
TO RESIDUE GAS <2psi (Clean)
COMPRESSORS PDI 10psi (Dirty)
TIC
REGEN GAS 450oF 1,255 psig
Water Vapor/Stripping Gas REGEN GAS COMPRESSORS
To Warm Flare GLYCOL DRY GAS
CONTACTOR REGEN GAS
F
490 psig SCRUBBER
110oF DRY GAS DUST TO CRYO UNIT
LIC Hot Oil
470 psig FILTERS
Lean Glycol TIC 110oF 5 MMscfd
TEG 440 psig REGEN GAS
99.5 wt%
REGENERATION REGENERATION
SYSTEM 35 gpm LIC FROM BOOSTER COMPRESSOR
GAS HEATER
REGEN GAS DISCH COOLER
COOLER
Rich Glycol
Water
CD
SISTEMA REGENERACION GLICOL (TREN #1 O #2)
Blanket Gas
Set @ 0.5 psig
From Fuel
Gas Header
Set @ 5 psig
GLYCOL OVHD
FROM COOLER
F
GLYCOL CONTACTOR 209oF
AND
REGEN GAS GLYCOL CONTACTOR 110oF
112oF GLYCOL REFLUX COIL
RICH TEG LC LC
128oF
GLYCOL Hydrocarbon
Set @ 50 psig REGENERATION Skim Liquid
Blanket Gas STILL Water To
From Fuel Disposal
Gas Header CD
GLYCOL FILL & TIC
GLYCOL FLASH Set @ 60 psig MAKE-UP 400oF
TANK GLYCOL REBOILER
F
LG
Hot Oil
128oF
60 psig
Stripping Gas FI
LC LC From Fuel Gas Header
TIC LIC
TIC
277oF
TO PRODUCT
STORAGE PROPANE RECOVERY 110oF TIC
38%
NGL PROD
PRODUCT
COOLER
MALVINAS PROCESS FLOW DIAGRAM
GAS CHILLDOWN & LIQUIDS RECOVERY SYSTEMS (SCORE w/ J-T)
FFIC
Set @ 495 psig
PIC F
BOOSTER COMPRESSOR
DISCH. COOLER 10% Of Inlet Rate
RESIDUE GAS GAS / GAS REFLUX 22MMscfd
FIC
470 psig EXCHANGER CONDENSER
TO RESIDUE PIC
-24oF
COMPRESSORS VVVVVVVV--VVVVVVVV
Residue 90oF
BOOSTER 470 psig VVVVVVV VVVVVVVV
Compressor
COMPRESSOR -23oF
Speed Control DEETHANIZER
(Bypassed) 19oF C EXPANDER
86% Inlet PC or FC
30oF O Signal
<
FROM DRY GAS SIC
DUST FILTERS C
FIC
Warm Gas Bypass Set @ FFC O O
DRY GAS +5oF 213MMscfd 1225psig -23oF
J-T VALVE
96oF TIC C
1,255 psig DEETHANIZER DEETHANIZER SIDE
219.8 MMscfd FEED PREHEATER LIQ / GAS EXCHANGE 473psig 0%
28oF LIC FIC
0gpm
VVVVVVVV--VVVVVVVV DEETHANIZER FFIC
14% 16oF
REFLUX
LIC
VVVVVVV VVVVVVVV COLD ACCUMULATOR FIC
SEPARATOR DEETHANIZER 100% 480 psig
Set @ 208gpm
HS TIC -19oF REFLUX PUMPS 230 gpm DEETHANIZER
O Pump Min Flow Recycle REBOILER
LIC
71oF TIC
TIC
277oF
TO PRODUCT
STORAGE PROPANE RECOVERY 110oF TIC
36%
NGL PROD
PRODUCT
COOLER
MANAGING PLANT PERFORMANCE
MAXIMIZING PROPANE RECOVERY
Max. Water Content Pisco C3 To Pass GPA Propane Dryness Test or D-2713-86
Max. CO2 Content, Mole % (Not Specified)
Corrosion Pisco C3 To Pass No.1 Copper Strip Test
Max. C2/C3 Ratio, LV% 2.0 (Pisco C3 Must Meet HD5 Spec)
Max. Design Pressure Of Storage, psig 250 psig @ 125oF
Normal Storage Op. Pressure, psig 70 psig @ 100oF
Max. Delivery Temperature To Storage, oF 110
Max. Delivery Pressure To Pipeline, psig 400
Max. Design Pressure Of Pumps, psig 450 @ 130oF
PRODUCT SPECIFICATIONS
MAINTAINING STABILIZED CONDENSATE ON SPEC
SLUG CATCHER
Operate at 1300 psig
Feed Liquids To Condensate Separator at Steady Rate
Service Sand Filter As Required To Keep Solids Out of the Condensate
CONDENSATE SEPARATOR
Operate at 485 psig
Maintain Water/Condensate Interface In Boot On Automatic Level Control
Maintain Condensate Liquid Level At Approximately 65-75% to Assure Residence Time For Water
Separation
CONDENSATE FLASH DRUM
Operate at 235 psig
Feed Liquids from Condensate Flash Drum on FIC w/ LIC resetting FIC
Maintain Liquid Level At Approximately 50-60%
STABILIZER BOTTOMS/FEED EXCHANGER
Maintain Feed To Stabilizer At 100oF
STABILIZER AND REBOILER
Maintain Reboiler Outlet Temperature Between 295 to 315oF
Calculate Stabilized Condensate C2/C3 Ratio Using Data From Chromatograph
Adjust Reboiler Temperature As Required to Maintain C2/C3 Ratio < 2.0 LV%
Use Stabilizer Reboiler Chart As A Guideline For Reboiler Temperature.
PRODUCT SPECIFICATIONS
MAINTAINING CRYO PLANT NGL PRODUCT ON SPEC PFD (SCORE)
PFD (GSP)
DEETHANIZER
Use Deethanizer Reboiler Charts (GSP J-T, GSP Expander, SCORE J-T, SCORE Expander)
Calculate C2/C3 Ratio Of Deethanizer Bottom Product Using Data From Chromatograph
Adjust Deethanizer Reboiler TIC as Required To Maintain C2/C3 Ratio < 2.0 LV%