Professional Documents
Culture Documents
CAJAMARCA
FACULTAD DE INGENIERIA
E.A.P. INGENIERIA CIVIL
1
INFORMACION REQUERIDA PARA EL DISEÑO DE MEZCLAS:
AGREGADO
PROPIEDAD AGREGADO FINO
GRUESO
Peso específico de masa.
Pe = 1150 kg/m^3
14 días 80%
X= 68.5714%
𝑓 ′ 𝑐 (28𝑑𝑖𝑎𝑠) . = 100∗491.313/68.5714 = 716.499 Kg/cm^2
𝒇′ 𝑪𝑹 = (𝒇′ 𝑪 )/(1-t*Cv)
1 55 57 64 652.3955148 878.2249003
n= 13
2 53 54 61 621.814475 837.0581081
X= 795.891316
3 52 52 59 601.4271152 809.61358
Sa = 88.5894866
4 55 57 64 652.3955148 878.2249003
Cva = 11.1308523
5 47 43.5 50 509.6839959 686.1132034
8 52 52 59 601.4271152 809.61358
9 59 60 67 682.9765545 919.3916925
13 58 60 67 682.9765545 919.3916925
PROBETA LECTURA DEL LECT. DEL ESCL L. E + RESISTENCIA A LOS RESISTENCIA A LOS 28
N* ESCL A 20* ERROR 10 DIAS kg/cm^2 DIAS kg/cm^2
1 48 45.5 52 530.0713558 713.5577315
n= 13
2 59 60 67 682.9765545 919.3916925
3 57 60 67 682.9765545 919.3916925 X= 800.746886
4 53 54 61 621.814475 837.0581081 Sb = 123.410621
5 44 38.3 44.3 451.5800204 607.8962982 Cvb = 15.411939
6 48 45.5 52 530.0713558 713.5577315
7 59 60 67 682.9765545 919.3916925
8 51 50.8 57.8 589.1946993 793.1468631
9 59 60 67 682.9765545 919.3916925
10 46 42 48.5 494.393476 665.5298073
11 42 35 41 417.9408767 562.6128268
12 59 60 67 682.9765545 919.3916925
13 57 60 67 682.9765545 919.3916925
PROBETA LECTURA DEL LECT. DEL ESCL L. E + RESISTENCIA A LOS RESISTENCIA A LOS
N* ESCL A 20* ERROR 10 DIAS kg/cm^2 28 DIAS kg/cm^2
1 57 60 67 682.9765545 919.3916925
2 53 54 61 621.814475 837.0581081
n= 13
3 47 43.5 50 509.6839959 686.1132034 X= 842.12479
4 49 47 53.5 545.3618756 734.1411276 Sc = 81.0964488
5 58 60 67 682.9765545 919.3916925
Cvc = 9.62997999
6 51 50.8 57.8 589.1946993 793.1468631
7 59 60 67 682.9765545 919.3916925
8 48 45.5 52 530.0713558 713.5577315
9 58 60 67 682.9765545 919.3916925
10 54 55.5 62.5 637.1049949 857.6415042
11 52 52 59 601.4271152 809.61358
12 58 60 67 682.9765545 919.3916925
13 57 60 67 682.9765545 919.3916925
1 en 20 1.645
1° CRITERIO:
1. POR GRANULOMETRÍA:
TMN= ¾”
MF= 2.2582
ANALISIS GRANULOMÉTRICO DEL AGREGADO GRUESO
1
%Ret. acum. 3´´, 1 2 ", 3/4", 3Τ8 " + 600
M. F Ag =
100
MF= 6.66234125
2° CRITERIO: 20/3 = 2.62” …. Peralte de la losa.
3° CRITERIO: 15/5 = 1.18” …. Entre encofrados.
4° CRITERIO: 3*e/4 …. Espacio entre refuerzos.
7.5cm
b. ¾” e = 8 – 1.905 = 6.095
c. 5/8” 8.0cm
e = 8 – 1.588 = 6.413
d. 5/8”
e = 8 – 1.588 = 6.413
FC = 𝟓𝟔𝟎 kg/m3
Nº = 13.176 bolsas/m3
.
NOVENO PASO: Calculo de los pesos de los aditivos.
mc = 5.20
3" 0 0 0 0 0 0
Agregado fino es = 33 %
Agregado grueso es = 67 %.
Treceavo paso: Volúmenes absolutos de los agregados:
AGREGADO FINO = 33% X 0.621m3 = 0.205 m3
AGREGADO GRUESO = 67% X 0.621 m3 = 0.416 m3
Humedad superficial:
Af =w% - % absorción = 4.2% – 1.18% = +4.68%
Ag =w% - % absorción = 0.98% – 1.45% = +0.23%
COSTOS:
Agregado fino = 0.213 m3 *90 S/m^3=19.17 S/.
Agregado grueso = 0.412 m3 *60 S/m^3=24.72 S/.
Aditivo 1 = 0.0093 m3 *70 S/m^3=0.65 S/.
Aditivo 2 = 0.0024 m3 *50 S/m^3=0.12 S/.
Aditivo 3 = 0.002m3 *60 S/m^3= 0.12 S/.
Fibra de acero = 0.0025m3 *120 S/m^3 =0.3 S/.
Cemento = 13.17 Bolsas/m^3=13.17*25=329.4 S/.
AJUSTE DE PROPORCIONES
Tal como se indicó en el acápite 28.2.1.1, la cantidad de agua requerida por metro cubico
de concreto deberá ser incrementada en 2lt. Por cada incremento de 1 cm hasta obtener
A/C=0.30
Con el incremento del aguan de mezclado deberá requerirse cemento adicional
para mantener la misma relación A / MC en 0.30 por lo tanto el nuevo contenido
de cemento
será :
FC=168.982/0.30=563.273 kg/m^3
9. CORRECCION EN EL AGREGADO GRUESO
Desde que el concreto fue encontrado sobrearenoso, la cantidad de agregado grueso por
unidad de volumen deberá ser incrementada en 10%.
El nuevo estimado para el peso del concreto, con 1.7% menor que el asumido de aire
será de :
Nuevo peso del concreto = 2410/ (1+1.7/100) = 2369.71 Kg /m3
11. CONTENIDO DE AGREGADO FINO
El peso del agregado fino requiere conocer primero el contenido de agregado grueso al estado de
saturado superficialmente seco:
De acuerdo a los ajustes efectuados, los nuevos pesos de la tanda, para un metro cubico de
concreto, como valores de diseño serán:
Cemento =563.273 kg/m3
Agua de disen = 168.982 lt/m3
Agregado fino seco = 419.395 kg/m3
Agregado grueso seco = 1212.64 kg/m3
Aditivo 1 = 11.2 kg/m3 Estos valores deberán ser corregidos por
Aditivo 2 = 2.8 kg/m3 condición de humedad de agregado a fin de
Aditivo 3 = 4.0 kg/m3 obtener los nuevos valores de obra.
Fibra de acero = 20 kg/m3
VALORES CORREGIDOS POR HUMEDAD
𝟏 ∶ 𝟎. 𝟕𝟖 ∶ 𝟐. 𝟏𝟕 𝟏𝟐. 𝟐𝟐 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔
13. CORRECCIÓN POR EL MÉTODO DE VOLÚMENES ABSOLUTOS
TOTAL 10044
T.M:3/4"
ABERTURA DE LOS TAMICES
Graficando la curva de Fuller
MALLA ABERTURA (MM)
2" 50
1" 25 A
3/4" 19
1/2" 12.5
3/8" 9.52
N° 4 4.75
N° 8 2.38
N° 10 2
N° 16 1.19
N° 20 0.85
N° 30 0.59
N° 50 0.3
N° 80 0.18
N° 100 0.15
N° 200 0.075
DE LA GRAFICA TENEMOS
C= 32
B= 0
A= 94
Pd : % que pasa por la
malla d
β= 65.96%
% en volumen absoluto del agregado grueso dentro de la
β: mezcla de agregados
INFORMACION REQUERIDA PARA EL DISEÑO DE LA MEZCLA:
AGREGADO
PROPIEDAD AGREGADO FINO
GRUESO
Peso específico de masa.
1" a 2" 205 200 185 180 160 155 145 125
3" a 4" 225 215 200 195 175 170 160 140
6" a 7" 240 230 210 205 185 180 170 …..
Cantidad aproximada de
aire atrapado. En 3 2.5 2 1.5 1 0.5 0.3 0.2
porcentaje
Según Fuller:
Debido a que el concreto es especial añadimos una adicion que aumente la resistencia mecánica
POR LO TANTO:
Peso seco del agregado grueso = 0.41 m3 X 2650 = 1095.07 -20= 1075.07 kg
Humedad superficial:
Af =w% - % absorción = 4.2% – 1.18% = +3.02%
Ag =w% - % absorción = 0.98% – 1.45% = - 0.47%
COSTOS:
Agregado fino = 0.22 m3 *90 S/m^3=19.80 S/.
Agregado grueso = 0.41 m3 *60 S/m^3=24.58 S/.
Aditivo 1 = 0.0093 m3 *70 S/m^3=0.65 S/.
Aditivo 2 = 0.0024 m3 *50 S/m^3=0.12 S/.
Aditivo 3 = 0.002m3 *60 S/m^3= 0.12 S/.
Fibra de acero = 0.0025m3 *120 S/m^3 =0.3 S/.
Cemento = 13.17 Bolsas/m^3=13.17*25=329.4 S/.
AJUSTE DE PROPORCIONES
Tal como se indicó en el acápite 28.2.1.1, la cantidad de agua requerida por metro cubico
de concreto deberá ser incrementada en 2lt. Por cada incremento de 1 cm hasta obtener
A/C=0.30
Con el incremento del aguan de mezclado deberá requerirse cemento adicional
para mantener la misma relación A / MC en 0.30 por lo tanto el nuevo contenido
de cemento
será :
FC=169.27/0.30=564.23 kg/m^3
9. CORRECCION EN EL AGREGADO GRUESO
Desde que el concreto fue encontrado sobrearenoso, la cantidad de agregado grueso por
unidad de volumen deberá ser incrementada en 10%.
El nuevo estimado para el peso del concreto, con 1.7% menor que el asumido de aire
será de :
Nuevo peso del concreto = 2410/ (1+1.7/100) = 2369.71 Kg /m3
11. CONTENIDO DE AGREGADO FINO
El peso del agregado fino requiere conocer primero el contenido de agregado grueso al estado de saturado
superficialmente seco:
De acuerdo a los ajustes efectuados, los nuevos pesos de la tanda, para un metro cubico de
concreto, como valores de diseño serán:
Cemento =564.23 kg/m3
Agua Efectiva = 169.27 lt/m3
Agregado fino seco = 418.788 kg/m3
Agregado grueso seco = 1195.15 kg/m3
Aditivo 1 = 11.2 kg/m3 Estos valores deberán ser corregidos por
Aditivo 2 = 2.8 kg/m3 condición de humedad de agregado a fin de
Aditivo 3 = 4.0 kg/m3 obtener los nuevos valores de obra.
Fibra de acero = 20 kg/m3
VALORES CORREGIDOS POR HUMEDAD
𝟏 ∶ 𝟎. 𝟕𝟕 ∶ 𝟐. 𝟏𝟒 𝟏𝟐. 𝟐𝟐 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔
13. CORRECCIÓN POR EL MÉTODO DE VOLÚMENES ABSOLUTOS
𝟏 ∶ 𝟎. 𝟗𝟎 ∶ 𝟐. 𝟏𝟒 𝟏𝟐. 𝟎𝟕 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔
INFORMACION REQUERIDA PARA EL DISEÑO DE MEZCLAS:
AGREGADO
PROPIEDAD AGREGADO FINO
GRUESO
Peso específico de masa.
Pe = 1150 kg/m^3
14 días 80%
X= 68.5714%
𝑓 ′ 𝑐 (28𝑑𝑖𝑎𝑠) . = 100∗491.313/68.5714 = 716.499 Kg/cm^2
𝒇′ 𝑪𝑹 = (𝒇′ 𝑪 )/(1-t*Cv)
1 55 57 64 652.3955148 878.2249003
n= 13
2 53 54 61 621.814475 837.0581081
X= 795.891316
3 52 52 59 601.4271152 809.61358
Sa = 88.5894866
4 55 57 64 652.3955148 878.2249003
Cva = 11.1308523
5 47 43.5 50 509.6839959 686.1132034
8 52 52 59 601.4271152 809.61358
9 59 60 67 682.9765545 919.3916925
13 58 60 67 682.9765545 919.3916925
PROBETA LECTURA DEL LECT. DEL ESCL L. E + RESISTENCIA A LOS RESISTENCIA A LOS 28
N* ESCL A 20* ERROR 10 DIAS kg/cm^2 DIAS kg/cm^2
1 48 45.5 52 530.0713558 713.5577315
n= 13
2 59 60 67 682.9765545 919.3916925
3 57 60 67 682.9765545 919.3916925 X= 800.746886
4 53 54 61 621.814475 837.0581081 Sb = 123.410621
5 44 38.3 44.3 451.5800204 607.8962982 Cvb = 15.411939
6 48 45.5 52 530.0713558 713.5577315
7 59 60 67 682.9765545 919.3916925
8 51 50.8 57.8 589.1946993 793.1468631
9 59 60 67 682.9765545 919.3916925
10 46 42 48.5 494.393476 665.5298073
11 42 35 41 417.9408767 562.6128268
12 59 60 67 682.9765545 919.3916925
13 57 60 67 682.9765545 919.3916925
PROBETA LECTURA DEL LECT. DEL ESCL L. E + RESISTENCIA A LOS RESISTENCIA A LOS
N* ESCL A 20* ERROR 10 DIAS kg/cm^2 28 DIAS kg/cm^2
1 57 60 67 682.9765545 919.3916925
2 53 54 61 621.814475 837.0581081
n= 13
3 47 43.5 50 509.6839959 686.1132034 X= 842.12479
4 49 47 53.5 545.3618756 734.1411276 Sc = 81.0964488
5 58 60 67 682.9765545 919.3916925
Cvc = 9.62997999
6 51 50.8 57.8 589.1946993 793.1468631
7 59 60 67 682.9765545 919.3916925
8 48 45.5 52 530.0713558 713.5577315
9 58 60 67 682.9765545 919.3916925
10 54 55.5 62.5 637.1049949 857.6415042
11 52 52 59 601.4271152 809.61358
12 58 60 67 682.9765545 919.3916925
13 57 60 67 682.9765545 919.3916925
1 en 20 1.645
1° CRITERIO:
1. POR GRANULOMETRÍA:
TMN= ¾”
MF= 2.2582
ANALISIS GRANULOMÉTRICO DEL AGREGADO GRUESO
1
%Ret. acum. 3´´, 1 2 ", 3/4", 3Τ8 " + 600
M. F Ag =
100
MF= 6.66234125
2° CRITERIO: 20/3 = 2.62” …. Peralte de la losa.
3° CRITERIO: 15/5 = 1.18” …. Entre encofrados.
4° CRITERIO: 3*e/4 …. Espacio entre refuerzos.
7.5cm
b. ¾” e = 8 – 1.905 = 6.095
c. 5/8” 8.0cm
e = 8 – 1.588 = 6.413
d. 5/8”
e = 8 – 1.588 = 6.413
FC = 𝟓𝟔𝟎 kg/m3
Nº = 13.176 bolsas/m3
.
NOVENO PASO: Calculo de los pesos de los aditivos.
mc = 5.20
3" 0 0 0 0 0 0
Agregado fino es = 33 %
Agregado grueso es = 67 %.
Treceavo paso: Volúmenes absolutos de los agregados:
AGREGADO FINO = 33% X 0.621m3 = 0.205 m3
AGREGADO GRUESO = 67% X 0.621 m3 = 0.416 m3
Humedad superficial:
Af =w% - % absorción = 4.2% – 1.18% = +4.68%
Ag =w% - % absorción = 0.98% – 1.45% = +0.23%
COSTOS:
Agregado fino = 0.213 m3 *90 S/m^3=19.17 S/.
Agregado grueso = 0.412 m3 *60 S/m^3=24.72 S/.
Aditivo 1 = 0.0093 m3 *70 S/m^3=0.65 S/.
Aditivo 2 = 0.0024 m3 *50 S/m^3=0.12 S/.
Aditivo 3 = 0.002m3 *60 S/m^3= 0.12 S/.
Fibra de acero = 0.0025m3 *120 S/m^3 =0.3 S/.
Cemento = 13.17 Bolsas/m^3=13.17*25=329.4 S/.
AJUSTE DE PROPORCIONES
Tal como se indicó en el acápite 28.2.1.1, la cantidad de agua requerida por metro cubico
de concreto deberá ser incrementada en 2lt. Por cada incremento de 1 cm hasta obtener
A/C=0.30
Con el incremento del aguan de mezclado deberá requerirse cemento adicional
para mantener la misma relación A / MC en 0.30 por lo tanto el nuevo contenido
de cemento
será :
FC=168.982/0.30=563.273 kg/m^3
9. CORRECCION EN EL AGREGADO GRUESO
Desde que el concreto fue encontrado sobrearenoso, la cantidad de agregado grueso por
unidad de volumen deberá ser incrementada en 10%.
El nuevo estimado para el peso del concreto, con 1.7% menor que el asumido de aire
será de :
Nuevo peso del concreto = 2410/ (1+1.7/100) = 2369.71 Kg /m3
11. CONTENIDO DE AGREGADO FINO
El peso del agregado fino requiere conocer primero el contenido de agregado grueso al estado de
saturado superficialmente seco:
De acuerdo a los ajustes efectuados, los nuevos pesos de la tanda, para un metro cubico de
concreto, como valores de diseño serán:
Cemento =563.273 kg/m3
Agua de disen = 168.982 lt/m3
Agregado fino seco = 419.395 kg/m3
Agregado grueso seco = 1212.64 kg/m3
Aditivo 1 = 11.2 kg/m3 Estos valores deberán ser corregidos por
Aditivo 2 = 2.8 kg/m3 condición de humedad de agregado a fin de
Aditivo 3 = 4.0 kg/m3 obtener los nuevos valores de obra.
Fibra de acero = 20 kg/m3
VALORES CORREGIDOS POR HUMEDAD
𝟏 ∶ 𝟎. 𝟕𝟖 ∶ 𝟐. 𝟏𝟕 𝟏𝟐. 𝟐𝟐 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔
13. CORRECCIÓN POR EL MÉTODO DE VOLÚMENES ABSOLUTOS
TOTAL 10044
T.M:3/4"
ABERTURA DE LOS TAMICES
Graficando la curva de Fuller
MALLA ABERTURA (MM)
2" 50
1" 25 A
3/4" 19
1/2" 12.5
3/8" 9.52
N° 4 4.75
N° 8 2.38
N° 10 2
N° 16 1.19
N° 20 0.85
N° 30 0.59
N° 50 0.3
N° 80 0.18
N° 100 0.15
N° 200 0.075
DE LA GRAFICA TENEMOS
C= 32
B= 0
A= 94
Pd : % que pasa por la
malla d
β= 65.96%
% en volumen absoluto del agregado grueso dentro de la
β: mezcla de agregados
INFORMACION REQUERIDA PARA EL DISEÑO DE LA MEZCLA:
AGREGADO
PROPIEDAD AGREGADO FINO
GRUESO
Peso específico de masa.
1" a 2" 205 200 185 180 160 155 145 125
3" a 4" 225 215 200 195 175 170 160 140
6" a 7" 240 230 210 205 185 180 170 …..
Cantidad aproximada de
aire atrapado. En 3 2.5 2 1.5 1 0.5 0.3 0.2
porcentaje
Según Fuller:
Debido a que el concreto es especial añadimos una adicion que aumente la resistencia mecánica
POR LO TANTO:
Peso seco del agregado grueso = 0.41 m3 X 2650 = 1095.07 -20= 1075.07 kg
Humedad superficial:
Af =w% - % absorción = 4.2% – 1.18% = +3.02%
Ag =w% - % absorción = 0.98% – 1.45% = - 0.47%
COSTOS:
Agregado fino = 0.22 m3 *90 S/m^3=19.80 S/.
Agregado grueso = 0.41 m3 *60 S/m^3=24.58 S/.
Aditivo 1 = 0.0093 m3 *70 S/m^3=0.65 S/.
Aditivo 2 = 0.0024 m3 *50 S/m^3=0.12 S/.
Aditivo 3 = 0.002m3 *60 S/m^3= 0.12 S/.
Fibra de acero = 0.0025m3 *120 S/m^3 =0.3 S/.
Cemento = 13.17 Bolsas/m^3=13.17*25=329.4 S/.
AJUSTE DE PROPORCIONES
Tal como se indicó en el acápite 28.2.1.1, la cantidad de agua requerida por metro cubico
de concreto deberá ser incrementada en 2lt. Por cada incremento de 1 cm hasta obtener
A/C=0.30
Con el incremento del aguan de mezclado deberá requerirse cemento adicional
para mantener la misma relación A / MC en 0.30 por lo tanto el nuevo contenido
de cemento
será :
FC=169.27/0.30=564.23 kg/m^3
9. CORRECCION EN EL AGREGADO GRUESO
Desde que el concreto fue encontrado sobrearenoso, la cantidad de agregado grueso por
unidad de volumen deberá ser incrementada en 10%.
El nuevo estimado para el peso del concreto, con 1.7% menor que el asumido de aire
será de :
Nuevo peso del concreto = 2410/ (1+1.7/100) = 2369.71 Kg /m3
11. CONTENIDO DE AGREGADO FINO
El peso del agregado fino requiere conocer primero el contenido de agregado grueso al estado de saturado
superficialmente seco:
De acuerdo a los ajustes efectuados, los nuevos pesos de la tanda, para un metro cubico de
concreto, como valores de diseño serán:
Cemento =564.23 kg/m3
Agua Efectiva = 169.27 lt/m3
Agregado fino seco = 418.788 kg/m3
Agregado grueso seco = 1195.15 kg/m3
Aditivo 1 = 11.2 kg/m3 Estos valores deberán ser corregidos por
Aditivo 2 = 2.8 kg/m3 condición de humedad de agregado a fin de
Aditivo 3 = 4.0 kg/m3 obtener los nuevos valores de obra.
Fibra de acero = 20 kg/m3
VALORES CORREGIDOS POR HUMEDAD
𝟏 ∶ 𝟎. 𝟕𝟕 ∶ 𝟐. 𝟏𝟒 𝟏𝟐. 𝟐𝟐 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔
13. CORRECCIÓN POR EL MÉTODO DE VOLÚMENES ABSOLUTOS
𝟏 ∶ 𝟎. 𝟗𝟎 ∶ 𝟐. 𝟏𝟒 𝟏𝟐. 𝟎𝟕 𝒍𝒕/𝒃𝒐𝒍𝒔𝒂𝒔