SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
BACKGROUND
79% of pump population in SLN is SPS Type.
About $20 million of OPEX in 2003.
Current OPEX running is about $1 million per
month.
January 2003 findings:
From all wells tested (37 wells) with MPFM, 21%
running with Improper design.
√ 80% due to under range capacity.
√ 20% due to insufficient stages
Potential OPEX saving due to SPS about $1
million/year.
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
OBJECTIVES
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
Objectives in Designing:
Maximize the incremental oil gain (not
necessarily the rate) or the NPV.
Influencing Factors:
Pump availability.
Reservoir capability.
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN Typical SPS Installation
Fuse Switchboard Wellhead Cable Feed
4 Main components in Junction
through
Transform
designing: er
ESP
CONTROL
Box
Well Head
Pump set
Power Cable
Pump size
Stages Pump
Motor lead extension
and cable guard
Motor size
4100 ‘ Pump Intake
Perforation >
Protector
Motor
Casing shoe
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
Consideration in designing:
How much fluid? Pump Size
Where is the intake? Pump set, Stages
How much power required? Motor size
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- PUMP SIZE
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- STAGES REQUIRED
Well Head
Pressure
Factors to overcome:
Tubing Friction
TDH = Hd + Ft + Pd
TDH
Stages
PUMP TABLE Head / Stages
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- IMPACT OF STAGES DESIGN
Well Head To Gathering Station
Pressure
Impact of Stages
Lacking
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- MOTOR SIZE
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- ON VSD APPLICATION WELL
Impact on power
3
NewFrequency
NewBHP BHP@ 60 Hz
60 Hz
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- ON VSD APPLICATION WELL
Impact on production
Production
Liquid Trend
Production ofof
Trend BKS #111
BKS # 111
Found outout
Found running onon
running HzHz 62.5
60 60 HzHz 6565
62.5 HzHz 67.5
67.5HzHz
2500 reversed.Set
reversed.Set to to Normal
Normal
2500
rate, bbl bfpd
2000
2000
Production,
1500
1500
1000
1000
LiquidOil
500
500
0
01 40 79 118 157 196 235 274 313 352 391 430 469 508 547 586 625 664 703 742
1 39 77 115 153 191 229 267 305 343 381 419 457 495 533 571 609 647 685 723 761
Time
Time
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS DESIGN
- ON VSD APPLICATION WELL
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS TROUBLESHOOTING
(Condition : Low Rate / Not Producing)
Not Pumping • Pump load is low (need to calculate the Fluid Not Downsize /
(Can be re-start) normal load and then compare the actual Support Workover
The pump can still be load to the normal load). (FNS)
function • FOP is low (Rule of thumb, below 500 ft).
• The fluid rate is below pump capacity.
• Pump load is low. Broken Shaft Recondition
• FOP is high and stable.
• The load during reversed rotation = the load
during forward rotation.
• No build up pressure on the surface.
• On the Amp Chart trend, there is sudden
decrease of Amp Load.
• The rate is below the pump capacity or no Under Stages Recondition w/
rate at all. Add Stages
• The pump load is normal.
• The load during reversed rotation < The load
during forward rotation.
• FOP is high.
• Still building up pressure at surface.
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS TROUBLESHOOTING
(Condition : Low Rate / Not Producing)
Not Pumping • Amp chart shows gassy trend. Gas Lock or Gas Recondition w/ GS
(Can be re-start) • The rate below pump capacity. Interference if Possible lower
The pump can still be • The pump load is not stable the pump set
function • The FOP can be uncertain (due to high
- Continued - gas).
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
SPS TROUBLESHOOTING
(Condition : Low Rate / Not Producing)
SPS DESIGN
Duri, 13th October 2004 – SPS FORUM DISCUSSION –
EXAMPLE OF SPS TABLE
(REDA TYPE)
Pump Cap. (BFPD) Head/stg HP/stg Stages
D400 280 - 550 23.6 0.143 73 92 110 129 148 165
DN450 350 - 550 18.5 0.128 94 113 188 207 266 282
TD450 350 - 550 18.1 0.130 50 100 150 200 250 300
DN750 550 - 950 24.5 0.230 75 94 113 133 152 169
TD850 550 - 1050 28.3 0.280 50 68 100 118 136 150
TD1200 800 - 1500 24.0 0.350 100 200 300 400 500 600
D1350 950 - 1800 21.4 0.330 72 91 109 128 147 163
GN2000 1650 - 2350 38.5 0.875 34 46 59 71 83 95
TG2000 1600 - 2700 38.0 0.980 100 200 300 400 500 600
GN3100 2500 - 3600 40.5 1.530 34 46 59 71 83 95
GN4000 3200 - 4500 35.0 1.480 19 25 39 46 52 75
GN5200 4400 - 6400 29.3 1.750 27 36 54 63 72 81
GN5600 5000 - 7250 26.5 1.820 27 36 54 63 72 81
GN7000 6000 - 8000 30.3 2.470 8 13 27 31 36 54
HN13000 9200 - 15200 45.0 6.380 15 30 41 45 60 71
M520 12000 - 24000 104.0 17.000 16 22 23 25 32 38
M675 19000 - 30000 117.0 27.000 14 15 28 29 30 42
SPS DESIGN