You are on page 1of 293

Warning

This publication is provided solely for the


immediate study needs of students enrolled at the
University of Al-Azhar, Cairo, A.R.E. for the
course directed by

Dr. Ossama El-Shall.


All rights reserved. No part of this publication may
be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means,
electronic, mechanical, printed, photocopying,
recording or otherwise without the written
permission of the author.
06/25/18 07:00 Ossama El-Shall
Dental Radiology
Dental Radiology
Dr. Ossama EL-Shall
Professor and Chairman of Oral
Medicine, Periodontology, Diagnosis and
Radiology Department.
Faculty of Dental Medicine for Girls
Al-Azhar University , Cairo Egypt.
06/25/18 07:00
E-mail address:Ossama
oelshall@hotmail.com
El-Shall
Dental Radiology course for post

graduate
Physics of Ionizing Radiation.
students.
 X-ray Machine.
 Biological effects of Radiation.
 Safety &Protection in dentistry.
 Dental X ray Film composition, (intra & extra-oral), Types & uses of intra-oral films.
 X-Ray film processing.
 Intra-oral radiographic techniques .
 Plain Extra-oral film projections .
 Panoramic Imaging.
 Faults affecting dental radiographs.
 Normal Anatomical Landmarks.
 Dental radiographic interpretation.
 Specialized techniques for imaging (Conventional tomography, CT, MRI, Nuclear
medicine, Ultrasonography, Sialography)
 Cone-Beam Computed Tomography

06/25/18 07:00 Ossama El-Shall


Contents of part I
1- Terminology.
2- Radiation Physics.
3- Properties of X-ray
4- Dental X-ray apparatus.
5- Production of X-rays.
6- Types of radiation.
7- Dental X-ray films, both intra-oral and
extra-oral.
8- X-ray film processing.
9- Intra-oral radiographic techniques.
06/25/18 07:00 Ossama El-Shall
Terminology
1- Radiology
2- Roentgenology
3- Dental radiology
4- Dental radiography
5- Radiograph
6- Radiation
7- Radiolucent
8- Radiopaque
06/25/18 07:00 Ossama El-Shall
Radiology

Science that deals with diagnosis,


therapeutic and researches application
of high-energy radiation.

06/25/18 07:00 Ossama El-Shall


Roentgenology

Science that deals with application


of X-ray on any field.

06/25/18 07:00 Ossama El-Shall


Dental radiology

It is the branch of science that


deals with the use of radiation in
diagnosis of dental diseases. 

06/25/18 07:00 Ossama El-Shall


Dental radiography

It is the art of producing an


image or picture for intra- or
extra-oral structures on a dental
film using X-ray.

06/25/18 07:00 Ossama El-Shall


Radiograph

It is the shadow features (image) received on a


radiation-sensitive film emulsion by exposure to ionizing
radiation directed through an area or region or substance
of interest, followed by chemical processing of the film.
It is basically dependent on the differential absorption
of radiation directed through heterogeneous media.
 

06/25/18 07:00 Ossama El-Shall


Radiation

It is the process of emission,


propagation and transmission of
energy by atoms in the form of
waves.

06/25/18 07:00 Ossama El-Shall


 
Radiolucent
Objects that permitting the passage of radiant
energy with relatively little attenuation by absorption
and appear black on the film, such as silicate
restoration, pulp tissues, gingiva, and carious lesion.
Another definition; Objects partly or wholly
penetrable by roentgen rays; the image of such
a material on the film ranges from dark gray to black.

RL

RL

06/25/18 07:00 Ossama El-Shall


 
Radiopaque

Objects that absorb X-rays and appear


white on radiograph, such as amalgam
restoration, enamel, and bone.
Another def.:Objects that not freely penetrable
by radiation.
OR Objects highly resistant to penetration by
roentgen rays; the image of such a material appears
on the film within range of gray to white.

06/25/18 07:00 Ossama El-Shall


Clinical Exam + Radiographs

Diagnosis

Treatment
06/25/18 07:00 Ossama El-Shall
Radiation physics

06/25/18 07:00 Ossama El-Shall


Radiation physics
Atomic structure:

1- Atom is the fundamental


unit of any particular
element, i.e. the basic unit
of an element.

2- It is composed of a
central nucleus and outer
orbits which spaced at a
definite distance from the
nucleus and are identified
by letters, K, L, M, N, O,
P, Q.
06/25/18 07:00 Ossama El-Shall
3-Electrons are negatively charged
particles that orbiting shells.

4-The central nucleus is composed of two


kinds of particles, proton, +ve charged
and neutrons with no charge.

5-Since neutrons have no charge; the


magnitude of the charge of the nucleus
will depend on the number of protons
(Atomic number), which are equal to the
number of electrons.
06/25/18 07:00 Ossama El-Shall
Atom states
Ground state (stable): It is the normal or ground state
of atom on which the atom is electrically neutral with
equal numbers of protons and electrons.

Excitation state: It occurs when sufficient energy


applied to the atom, results in removing of electron
from its normal shell to a higher energy shell.

Ionization state: It is the process by which an atom


loses its electrical neutrality and become ions by
either addition or removing of electrons. If electron
is added or removed from the atom, the atom will
termed as ion. If the electron is removed, the atom
becomes a +ve ion while the removed electron is
called –ve ion.
06/25/18 07:00 Ossama El-Shall
Atom (electrically stable)

K-shell
protons
L-shell
neutrons
M-shell
electrons

Atomic Number (Z) = # of protons


06/25/18 07:00 Ossama El-Shall
ELECTROSTATIC FORCE

Attraction between
protons and electrons

06/25/18 07:00 Ossama El-Shall


CENTRIFUGAL FORCE

Pulls electrons away


from nucleus

06/25/18 07:00 Ossama El-Shall


EF CF

Balance between electrostatic


force and centrifugal force keeps
electrons in orbit around nucleus

06/25/18 07:00 Ossama El-Shall


Nature of radiation

Radiation may be either

Corpuscular radiation

Electromagnetic radiation

06/25/18 07:00 Ossama El-Shall


A- Corpuscular or particulate radiation

1- It is that type of radiation given off from radium,


radioisotopes, and during splitting of the atom.

2- It is composed of solid subatomic particles having


mass and charge.

3- It travels in straight lines and is not used in


dental diagnostic filed but in therapeutic means.

4- Examples for corpuscular radiation:


Alpha (α) rays.
Beta (β) rays.
06/25/18 07:00 Ossama El-Shall
B- Electromagnetic radiation

1-It is that type of radiation formed of units


of pure energy, which are propagated in the
form of waves as a combination of electric
and magnetic fields.

2-It is made of pure energy propagate in a


form of waves with no mass or charge.

3-It is generated when the velocity of an


electrically charged particle is altered.
06/25/18 07:00 Ossama El-Shall
4-They travel in straight lines with the
same speed of light (3x108 meter/sec.)

5-As they propagate in a form of waves,


they have a wavelength (λ) and
frequency (ν(

06/25/18 07:00 Ossama El-Shall


λ

Wavelength (λ) is the distance between


2 crests or bottoms of 2 successive
waves.

Frequency (ν) is the number of cycles


or waves emitted/sec.
06/25/18 07:00 Ossama El-Shall
λ

F
Wavelength x Frequency = Speed of wave

06/25/18 07:00 Ossama El-Shall


According to the wavelengths, radiations
can differ in their properties.

Radiation may be of

Short wavelength
Or
Long wave length

06/25/18 07:00 Ossama El-Shall


The short wavelength increased
frequency increase the energy
accompanied with it increase
the power of penetration the rays
will termed Hard radiation which
characterized with low power of
absorption into matter and low
ionization.

06/25/18 07:00 Ossama El-Shall


The long wavelength decreases
frequency decrease the energy
accompanied with it decrease
the power of penetration the
rays are termed Soft radiation which
characterized with high power of
absorption into matter and high
ionization effects.

06/25/18 07:00 Ossama El-Shall


A
Highest energy
B Shortest wavelength
Highest frequency
C
Highest energy?
06/25/18 07:00 Ossama El-Shall
Examples of electromagnetic radiation
arranged in an ascending order according to their
wavelength:
1-Cosmic rays.
2-Gamma Ray
3-X.Ray. wavelength = 0.1-1Ao, Ao = 10-10 m
4-Ultraviolet rays.
5-Visible light.
6-Infra-red.
7-Microwaves.
8-Radio, radar, T.V waves.

06/25/18 07:00 Ossama El-Shall


Electromagnetic Spectrum

radio tv visible x-rays gamma cosmic


light rays rays

06/25/18 07:00 Ossama El-Shall


History History History

X-ray
X-rays were first discovered in
1895 by Wilhelm Conrad Roentgen,
the professor of physics and
director of the physics institute at
the University of Wurzburg in
Bavaria.

Hence the term ROENTGEN


RAYS, often applied to mechanically
generated x-rays. He won a Noble
prize for his discovery of X-ray.

Roentgen called them X-rays


after the mathematical symbol X
for unknown.
06/25/18 07:00 Ossama El-Shall
History History History

X-ray of Bertha Roentgen's Hand

Roentgen soon found that


photographic plates were sensitive to the
newly discovered rays.
He convinced his wife to participate in
an experiment.
Roentgen placed her hand on a
cassette loaded with a photographic
plate. He then aimed the activated
cathode ray tube at her hand for fifteen
minutes.
When the image was developed, the
bones of her hand and the two rings she
wore were clearly visible.

06/25/18 07:00 Ossama El-Shall


History History History

Within 2 weeks after Roentgen


was made his discovery public, the
first dental radiograph was made
by German dentist Otto Walkoff,
who placed in his own mouth small
glass photographic plates wrapped
in rubber dam and exposed them
for 25 minutes.

06/25/18 07:00 Ossama El-Shall


History History History

Early x-ray machine. Arrow points to


“live” electrical wire.
06/25/18 07:00 Ossama El-Shall
Definition of X-ray
- It is a type of electromagnetic radiation
characterized by wavelengths between
approximately 1 A and 10-4 A.

- They are invisible, penetrative especially


at higher photon energies, and travel with
the same speed as visible light.

- They are usually produced by bombarding


a target of high atomic number with fast
electrons in a high vacuum
06/25/18 07:00 Ossama El-Shall
In brief: X rays are a form of pure
energy units belonging to electromagnetic
spectrum characterized by having a very
short wave length and have the ability of
producing shadiness’ or images of the
body tissues.

06/25/18 07:00 Ossama El-Shall


Properties of X-ray

06/25/18 07:00 Ossama El-Shall


Properties of X-ray

1- They have a very short wave


length: As the wavelength decrease,
the power of penetration of the x-ray
increased. The power of penetration
depends on several factors in addition
to the wavelength such as: Atomic
number of the object, thickness of the
object, and the density of the object.
06/25/18 07:00 Ossama El-Shall
2- They have a selective penetration,
absorption power: When the x-ray hit
an object, certain interactions occur,
these interactions may occur in either
of 3 forms or possibilities: a)
Penetrate the object, b) Absorbed by
the object, c) Deflected from certain
objects e.g. heavy metals

06/25/18 07:00 Ossama El-Shall


3- It affects photographic film’s
emulsion: X-rays upon falling on the
emulsion of a photographic film they
cause physical changes producing what
is termed Latent Image formation,
which cannot be seen except after
chemical application.

06/25/18 07:00 Ossama El-Shall


4- It causes certain substances to
fluoresce: X-ray can cause certain
fluorescing substances to fluoresce or
emit “violet blue visible light” which is
of a longer wave length than the x-
rays so this was used in dentistry in
the formation of intensifying screen.

06/25/18 07:00 Ossama El-Shall


5- They cause ionization of atoms: X-
rays have the power of converting
atoms into ions with the formation of
ion pairs which are electrically
charged, unbalanced, non-functioning
cells thus will have a harmful effect
later on the body cells and fluids.

06/25/18 07:00 Ossama El-Shall


6-They have biological damaging
effects: May be of somatic effects
such as skin burns, erythema or cancer
or genetic effects

06/25/18 07:00 Ossama El-Shall


7. Travel in straight lines in wave motion with
the same speed of light.3x108 meter/sec.

8. Short waves about 1/10000 of that of light.


(0.1-0.001nm)

9. Invisible, can’t be felt, smelled or heard.

10. Weightless, mass less, and changeless.

06/25/18 07:00 Ossama El-Shall


11. They cannot be focused or collected by a
lens.

12. They cannot be reflected by a mirror or


by fluids.

13. They cannot be deviated by a magnet.

14. They can deflect on heavy metals by


deviated into a new linear trajectory.

06/25/18 07:00 Ossama El-Shall


X-Ray Machine

06/25/18 07:00 Ossama El-Shall


Dental X-ray apparatus
How are X-rays created?

 When fast-moving electrons (minute particles each


consisting of a negative electrical charge) collide
with matter, X-radiation is produced.
 The most efficient means of generating X-rays is an
X-ray tube.
 In it, X-rays are produced by directing a high-
speed stream of electrons against a metal target.
 As they strike the atoms of the target, the
electrons are stopped.
 Most of their energy is transformed into heat, but a
small proportion is transformed into X-rays.
06/25/18 07:00 Ossama El-Shall
X-ray machine consists of
Tube: Cathode + Anode

Head
Accessories:
Filters + collimators + cones

Automatic
Timer

Manual
06/25/18 07:00 Ossama El-Shall
X-ray Tubehead
06/25/18 07:00 Ossama El-Shall
support arms

Tubehead

Timer

06/25/18 07:00 Ossama El-Shall


Automatic timers

1- Direct or immediate timers: It attached


to a long cord to enable the operator to
go away from the field of radiation.
Operator press on a button just to
activate the exposure while the time is
pre adjusted and the exposure will stop
automatically even if the operator
continuous to press the button.

2- Delayed timers: This type provide about 9


second before the start of exposure, so it
provides the operator a period to get away
from the field of radiation.
06/25/18 07:00 Ossama El-Shall
Timer

exposure time
adjustment

06/25/18 07:00 Ossama El-Shall


06/25/18 07:00 Ossama El-Shall
Manual timers
- Direct type in old x-ray machines

-The exposure is controlled manually


(like the clock alarm) and exposure will
stop only if the operator stop pressing
on the button.

- The main disadvantage of this type


that it adjusted only for 1 second not in
fraction of seconds.
06/25/18 07:00 Ossama El-Shall
Manual Timer
06/25/18 07:00 Ossama El-Shall
Head of X-ray machine.

It consists of two main parts

Tube

Accessories.

06/25/18 07:00 Ossama El-Shall


The Tube
The Tube is an Evacuated glass tube with
two arms or electrodes extending in two
opposite directions, which are the cathode and
anode.

The tube is evacuated for two reasons


1) This will prevent collision of the moving
electrons with the molecules of the air.
2) This evacuation will prevent oxidation and
burn out of the filaments.
06/25/18 07:00 Ossama El-Shall
Tube head of X-ray machine

06/25/18 07:00 Ossama El-Shall


Cathode
It is the negative electrode of the
tube, which serves as the source
of electrons. It consists of two
parts

a) Filament.

b) Focusing cup.
06/25/18 07:00 Ossama El-Shall
Cathode

Filament
(tungsten)

Focusing
cup
(molybdenum)
06/25/18 07:00 Ossama El-Shall
Filament
It made of tungsten coil, which is 0.2cm in
diameter and 1 cm or less in length.

Tungsten is used because;


1) It has a very high melting point so it can
withstand the high temperature accompanied
with the process of X-ray production.

2) It has a high atomic number, which


denoting a high number of protons resulting in
high number of electrons.
06/25/18 07:00 Ossama El-Shall
Focusing cup

It is a negatively charged concave


reflector cup made of molybdenum, act as
focusing to the electrons to a narrow beam
to fall on the target.

The high negative charge of the cathode


repels the negatively charged electrons,
thus this cup collects the electrons and
repels them till the anode attracts them.

06/25/18 07:00 Ossama El-Shall


Electrons Emission
Release of electrons from hot filament when
current flows after depressing exposure switch

hot
filament
filament
electrons

The hotter the filament gets, the greater


the number of electrons that are released.
06/25/18 07:00 Ossama El-Shall
Anode

It consisting of two main parts

a) Target.

b) Copper head.

06/25/18 07:00 Ossama El-Shall


Anode

side view front view

Target
Copper head Target

06/25/18 07:00 Ossama El-Shall


Target

It made up of tungsten due to

1) It has a very high atomic number (i.e.


large number of protons and electrons).

2) It has a high melting point.

3) It has a very poor thermal conductivity.

06/25/18 07:00 Ossama El-Shall


Copper head

Due to the poor thermal conductivity


of the tungsten target, it is embedded
in a large block of copper, which is a
good thermal conductor so it allows
proper dissipation of heat which
accompanies the process of X-ray
production.

06/25/18 07:00 Ossama El-Shall


X-ray Production

06/25/18 07:00 Ossama El-Shall


A simplified diagram of x-ray tube 220 v

Cathode Anode
Step-down Step-up
transformer transformer

Filament 60-90 kvp


E Target
8-12 v
Copper
head

Focusing cup 1ry Ray


Insulating oil

Metal housing
Evacuated Glass tube

Useful beam
06/25/18 07:00 Ossama El-Shall
Production of X-rays
Terminology:

Volt
Voltage
Ampere
Transformer
06/25/18 07:00 Ossama El-Shall
Volt: It is the unit of electrical pressure or
electromotive force necessary to produce
a current of 1 ampere through a
resistance of 1 ohm.

OR

It is the unit of measuring the potential


difference of a charge to move from one
electrode to the other

06/25/18 07:00 Ossama El-Shall


Voltage: It is the potential or
electromotive force of an electric charge,
expressed in volts.

OR

The potential difference between 2


electrical charges, e.g. between cathode
and anode.

06/25/18 07:00 Ossama El-Shall


Ampere: It is the practical unit of quantity
of electronic current, equal to a flow of 1
coulomb per second or the flow of 6.25 x
1018 electrons per second.

06/25/18 07:00 Ossama El-Shall


 Transformer: It is an electrical device,
which increases or reduces the voltage of
an alternating current by mutual induction
between primary and secondary coils.

 Step-down transformer: A transformer in


which the secondary voltage is less than
primary voltage.

 Step-up transformer: A transformer in


which the secondary voltage is greater than
the primary voltage.
06/25/18 07:00 Ossama El-Shall
The principles of X-ray production

When an electric current, -which composed of


a steam of negatively charged electrons having
kinetic energy- passes through a filament or
wire, it will be heated so the orbiting electrons
within its atoms will acquire sufficient energy to
escape from their shells. Finally this electron
cloud will be given from the heated wire of
filament.
If these electrons sudden stopped, they will
loose the accompanying kinetic energy and
converted into heat and X radiation.
06/25/18 07:00 Ossama El-Shall
Application of this principle on dental
X-ray machine
The step-down transformer will decrease the
electric current into 8-12 volts.

This current is sufficient enough to heat the


tungsten filament of the cathode and produce
electrons according to the degree of heating
by thermo ionic emission.

These electrons will form a cloud around the


cathode, which will be collected by the concave
focusing cup but they have no velocity to move.
06/25/18 07:00 Ossama El-Shall
The step-up transformer will raise the potential
difference between the cathode and the anode
by raising the voltage into 60-70 KV.
This increase in potential difference will
accelerate the electron cloud to move towards
the anode, as there is a force of attraction
between the positive anode and the negative
cathode.
By the action of the focusing cup, the electrons
will hit only the tungsten target of the anode,
loosing their kinetic energy in a form of 99.8%
heat and only 0.2% X-rays.
The produced X-rays (primary beam) are
conducted to get out from the tube housing
through the filters and collimators to be used as
a 06/25/18
useful 07:00 beam. Ossama El-Shall
Tube of x-ray machine

06/25/18 07:00 Ossama El-Shall


X-ray Machine Components

oil

filament filter

exposure
button

06/25/18 07:00 Ossama El-Shall


Accessories

Filters

Collimators

Cones

06/25/18 07:00 Ossama El-Shall


Filters
A thin sheet of pure aluminum placed in the way of
the X-ray beam at the end of the X-ray tube in
order to improve the quality of the beam.

The X-ray beam is heterogeneous in characteristics


i.e. containing a ray of different energies and
wavelength. Because of this, the filter is used in
order to absorb unnecessary x-rays of the longer
wavelengths being both useless in radiography and
dangerous to the patient and the dentist.

The thickness of the filters varies according to the


Kvp of the machine being used, 2mm.Al thickness
with up to 70Kvp and 2.5mm over 70Kvp.
06/25/18 07:00 Ossama El-Shall
PID

The filter is usually


located in the end of
the PID which
attaches to the
tubehead.
filter
06/25/18 07:00 Ossama El-Shall
Types of filters

Added filters: They are external filters that


can be removed or added by the clinician.

Inherent filters: These include the glass wall


of the X-ray tube, The insulating oil, and
the metal housing

Total filters = Inherent filters + added


filters.
06/25/18 07:00 Ossama El-Shall
Total Filtration

Aluminum filter (s)

Added

2.5 mm

Glass window
Total 70 kVp
Oil/Metal barrier 1.5 mm
of x-ray tube
Inherent

06/25/18 07:00
Collimator

It is a device used to limit or restrict


the size of an X-ray beam just to
cover the film to produce the desire
image.

06/25/18 07:00 Ossama El-Shall


Types of collimators

Diaphragm collimator: A thin sheet of lead with an


opening in the center.

Tubular collimator: A tube of lead with one of its ends


connected or in conjunction to the diaphragm
collimator. This tube will help in decrease diverging
rays and almost increase more parallel rays, which in
turn helps in increase quality of image and more safe
to the patient.

Rectangular collimators: It provides a beam of a


rectangular shape that larger than the size of
Periapical films.
06/25/18 07:00 Ossama El-Shall
Collimation
front views side view

collimated
collimator beam

target
(x-ray source)

2.75 inches (7 cm) = maximum diameter of circular beam or maximum


length of long side of rectangular beam at end of PID.
06/25/18 07:00 Ossama El-Shall
Collimator

You are looking up through the PID at the collimator, which is


a circular lead washer with a circular cutout in the middle. This
will produce a round x-ray beam. The light gray area in the
center is an aluminum filter, which is placed on the tubehead
side of the PID.
06/25/18 07:00 Ossama El-Shall
7 cm If you switch from a
6 cm 7 cm round PID to a 6
cm round PID, the
6 cm round
patient receives 25%
less radiation.

film
(4.5 cm long)

Rectangular collimation
results in 55 % less
entrance radiation when compared
to 7 cm round PID.
entrance
exit
exit

06/25/18 07:00 Ossama El-Shall


Cones, Position indicating device
(PID)

It is a device used to

1-Fix the target film distance


2-Indicate the point of the entry

3-Determine the direction and distribution of


the X-ray tube.

06/25/18 07:00 Ossama El-Shall


It may make of plastic, glass or metal. The majority
of cones are made of plastic because it is light. In
case of metal one (lead) it may act as collimator and
cone in the same time, but it is not practical as it
very heavy on the tube itself and will cause decrease
beam intensity as some of it will be absorbed by the
lead.

It may be of opened end or pointed end shape. The


pointed end shape has harmful effects that it acts
as a source of scattered radiation as the rays will
hit its walls.

It may be short one 8” or long one 16”.

06/25/18 07:00 Ossama El-Shall


16” FFD image
Target
16” from film Target
8” from film 8” FFD image
Film
Increasing the distance from the target of the x-ray tube
(focal spot, focus) to the object (teeth/film) (FFD = focus-film
distance) will result in an increase in sharpness and a decrease in
magnification. This results when a longer PID (cone) is used.

Moving the film closer to the teeth will also increase sharpness
and decrease magnification.
06/25/18 07:00 Ossama El-Shall
Types of X-ray

06/25/18 07:00 Ossama El-Shall


Types of X-Radiation
1- Primary radiation.
2- Useful beam
3- Central ray
4- Secondary radiation
5- Scattered radiation
6- Stray radiation
7- Remnant radiation
8- Leakage radiation
9- Soft radiation
10-Hard radiation
06/25/18 07:00 Ossama El-Shall
Primary radiation: It is the radiation coming
directly out of the target, most of it is
absorbed by the tube housing except for
the useful beam.

Useful beam: It is that part of the primary


radiation, which is not absorbed by the
housing but passes through the apparatus
and affects the film.

Central ray: It is that part occupying the


central portion of the useful beam on
which the rays are relatively parallel to
each other.
06/25/18 07:00 Ossama El-Shall
Secondary radiation: It is that radiation
generated from the patient’s surrounding
objects due to passage, interaction of the
primary beam with these objects. They are
of a long wavelength and so increased
absorption and are more dangerous to the
patient.

Scattered radiation: It is a form of


secondary radiation which has been deviated
in direction during passage of the X- rays
through objects.
06/25/18 07:00 Ossama El-Shall
Stray radiation: This radiation occurs when
the primary beam hits a metal heavier
than AL, e.g. metallic eyeglasses.

Remnant radiation: It is that portion of


radiation remaining or emerging from the
object after the passage of the primary
beam through it, to expose the film and
produce the image.

Leakage radiation: The radiation that escapes


through the protective housing of the X-
ray tube.
06/25/18 07:00 Ossama El-Shall
Soft radiation: Radiation produced by
decreased kilo-voltage, are of longer
wavelength, decreased penetration, increased
absorption so have a more damaging effect.

Hard radiation: Radiation produced by


increased kilo-voltage, are of shorter
wavelength, increased energy, increased
penetration, decreased absorption and are
the ones used to produce the image, i.e. of
diagnostic value.
06/25/18 07:00 Ossama El-Shall
Factors affecting the quality of an image

Terminology
Image
Contrast
Density
Exposure
Roentgen
Rad
Rem
06/25/18 07:00 Ossama El-Shall
Image:
The representation or semblance of a
structure or structures produced by
passage of X-radiation,
visible only when transmitted onto a
fluorescent screen or an x-ray film (in the
latter case, visible only after processing
the film).

06/25/18 07:00 Ossama El-Shall


Contrast:
It is the difference in density appearing
on a radiograph.
OR
Is the differentiation between black,
white and gray shades on the radiograph.

06/25/18 07:00 Ossama El-Shall


Density:
It is the degree of darkening of exposed
and processed photographic or x-ray film,
expressed as the logarithm of the opacity
of a given area of the film.

06/25/18 07:00 Ossama El-Shall


Exposure:
A measure of the x radiation to which a
person or object, or a part of either, is
exposed at a certain place, this measure
being based on its ability to produce
ionization.

06/25/18 07:00 Ossama El-Shall


Roentgen; R:
X-radiation has a property of causing
ionization of the matter that passes
through it.
So, the unit of x-rays is Roentgen, which is
the measurement of ionization.

It is defined as the amount of radiation


that passes in one c.c. air producing two
billion ion pairs (–ve and +ve) under
standard conditions of temperature and
atmospheric pressure
06/25/18 07:00 Ossama El-Shall
Rad:
It is unit of absorbed dose; it is amount of
ionizing Radiation absorbed dose by one gram
of the tissues.

Rem:
It is the unit of biological damaging effect of
radiation (B.D.E),
it is the amount of ionizing radiation produces
biologic damage effects (B.D.E) in one gram of
tissue.
It is Roentgen equivalent mass, i.e.
measurement unit denoting amount of a
radiation dose that produced biological
damaging effects equal that in a person with
one Roentgen of X-ray.
06/25/18 07:00 Ossama El-Shall
The factors affecting the quality
of an image
1- Kilo-voltage
2- Milliamp rage
3- Collimation
4- Filtration
5- Distance
6- Atomic number and thickness (density) of the

object

06/25/18 07:00 Ossama El-Shall


Kilo-voltage
Kilo voltage power of conventional dental X-
ray machine ranges from 65-90 kvp.

X-ray penetration power is controlled with kvp,


i.e. the higher the kvp is, the shorter
wavelength x-ray with high penetration power.

So kvp is the factors, which determine the


quality of the x-ray beam, and when the
thickness of the structure increased we need a
higher kvp.
06/25/18 07:00 Ossama El-Shall
Kilo-voltage
If the kvp is increased above the normal
range it will affect the contrast of the image.

In this case of very high kvp, the penetration


power of the x-ray will increase resulting in
nearly complete penetration of the objects and
finally blacking the film and the areas which
should have been white (as metal) will appear
gray.
The end result of such image will be image
with black and gray shades with low contrast
image (long gray scale).
06/25/18 07:00 Ossama El-Shall
Kilo-voltage

If the kvp will decrease than the normal, the


penetration power of the beam will decreased
resulting in image with white color
representing hard objects and few blacking or
gray represent soft tissue objects, which is
called high contrast image or (low gray scale).
Thus an optimum contrast is required which is
achieved by range of kvp between 65-90, any
alterations in this range either increase or
decrease will affect the quality of the image
contrast.
06/25/18 07:00 Ossama El-Shall
Milliamp rage

The normal range of mA is about 5-15, it


is affecting the quantity of the x-ray.

By controlling mA and time we can


control the quantity of the beam, and
thus control the density of the image.

06/25/18 07:00 Ossama El-Shall


Milliamp rage

The higher mA (within normal range) will


result in increase the quantity of the current,
increase heating of the coil, increase the
amount of electrons emitted, increase the
number of x-ray photons, increase the amount
of x-ray reaching the film, with final resultant
of increasing the amount of blacking of the
image resulting in an image with good density.

06/25/18 07:00 Ossama El-Shall


While if the mA is increased above the
normal range this will result in increasing
the darkness of the image (high density),
which may controlled or avoided by
decreasing the time of exposure.

06/25/18 07:00 Ossama El-Shall


If the mA is low than the normal range
it will result in a very light image with
low density, which is may control by
increasing the exposure time.

06/25/18 07:00 Ossama El-Shall


Collimation
Collimators exerts three main functions,
the first increase the safety to the patient,
the second, increase the quality of the image
the third is increase the sharpness of the
image.
It helps on reduction the amount of x-ray
reached to the patient and in the same time
increase the image quality by decreasing the
amount of scattered radiation. The image
sharpness will also increased by reduction of
the beam size, leads to reduction the more
diverging rays and increase the more parallel
rays.
06/25/18 07:00 Ossama El-Shall
Filtration

Proper filtration will provide x-rays with


short wavelength, results in a good
quality image.
Over-filtration will result in decrease the
amount of x- ray photons and in
decreased density image, while under-
filtration will give a long wavelength x-
rays with low penetration power and low
contrast image..
06/25/18 07:00 Ossama El-Shall
Distance
The distance between the source and the object
may affect the image quality as follow;
if the distance is increased, the intensity of the
beam will decreased leading to decrease of the
quality of the rays and affection to the density,
but in the same time if the distance is increased
it help on production of less diverging rays
leading to increase the quality of the beam and
increase the sharpness.
If the distance is decrease, this will help on
increase the intensity of the beam and increase
the density; while in the same time will increase
the divergent rays leading to decrease the
sharpness.
06/25/18 07:00 Ossama El-Shall
Atomic number and thickness (density)
of the object
As the atomic number, density and
thickness of the object increase, the
need for more powerful x-radiation will
increase to produce a good image. So the
kvp should increased but within limits in
order not to alter the contrast. So this
may compensate with increase the
exposure time, but also within limits in
order not to affect the density.
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Dental X-ray film

06/25/18 07:00 Ossama El-Shall


Dental X-ray film
It is a thin, transparent sheet of plastic
material coated on both sides with an emulsion
sensitive to radiation and light.

Radiographic films closely resemble the films


used by photographers to produce black and
white negatives.

There are differences in that photographic


films only carry an emulsion on one side of the
film base, whereas both sides of radiographic
films are coated, to double the response to an
X-ray exposure.
06/25/18 07:00 Ossama El-Shall
The X-ray film basically consists of
four components:
 Film base

 Adhesive layer

 Film emulsion

 Protective layer

06/25/18 07:00 Ossama El-Shall


Film base

Is a flexible piece of plastic, about 0.008


inches thick to provide the desired degree of
stiffness and flatness for handling.

It is transparent and has a slight blue tint


to make it easier to visualize the image.

Film base serve as a stable support for the


emulsion.

06/25/18 07:00 Ossama El-Shall


Adhesive layer

It is a thin layer of adhesive


material to act as attachment
between the base and emulsion from
both sides.

06/25/18 07:00 Ossama El-Shall


Film emulsion
1. This is the most important constituent of
the film.

2. It is a homogeneous mixture of gelatin and


silver halide crystals coated on both sides of
the film base to provide maximum speed to
the film (sensitivity).

3. Gelatin is used to suspend and evenly


disperse the silver halide crystals.
06/25/18 07:00 Ossama El-Shall
4. Halide crystal is a chemical compound
that is sensitive to radiation or light.

5. The halides used in a dental X-ray film


are silver bromide and to a lesser
extent silver iodide.

6. On exposure to the X-ray this silver


bromide absorb the rays and physical
changes take place in the emulsion.
This change called the latent image.
06/25/18 07:00 Ossama El-Shall
Protective layer

It is a thin, transparent, clear


layer of gelatin covers the emulsion to
protect it from mechanical damage.

06/25/18 07:00 Ossama El-Shall


What is the latent image and how it formed?

Silver bromide crystals absorb X-radiation, and


store the energy of the radiation as a certain
pattern to an extent depending on the density of
objects.

This pattern of energy on the exposed film cannot


be seen and is referred to as latent image.

The latent image remains invisible within the


emulsion until the film undergoes chemical processing,
then it become visible.

06/25/18 07:00 Ossama El-Shall


When the X-ray hit the surface of
emulsion, the silver bromide crystals that
exposed to the rays ionized and separated
to silver and bromide atoms.

However, when the exposed film is


treated with a solution called a developer, a
chemical reaction takes place, and the
exposed grains of silver compound are
transformed to tiny masses of black metallic
silver.

The unexposed grains are essentially


unaffected. It is this silver suspended in
the gelatin that constitutes the visible image
on the radiograph.
06/25/18 07:00 Ossama El-Shall
Latent Image
Air/soft tissue Bone Amalgam/Metal
Many x-rays Fewer x-rays Few, if any, x-rays
penetrate and ionize penetrate and not as penetrate; silver
many silver halide many silver halide halide crystals not
crystals crystals are exposed exposed

06/25/18 07:00 Ossama El-Shall


Types of Dental X-ray films

Intra-oral films

Extra-oral films

06/25/18 07:00 Ossama El-Shall


Films used in dental radiography come in a
variety of sizes and packaging.

Those of the smaller sizes suitable for


Intra-oral use, ranging from 22 to 31 mm
across and from 35 to 54 mm in length,
come individually enclosed in light-tight
envelopes of thin plastic or paper.

Other films of large size are used for


extra-oral exposure in dental radiography.
They positioned outside the oral cavity in a
special light protected holder (cassette)
that is loaded within the selected film inside
the dark room.
06/25/18 07:00 Ossama El-Shall
I- Intra-oral films

Intra-oral films usually supplied inside special


film packets. The film packet consists of:

1-Outer packet wrapping or envelope

2-Black paper film wrapping

3-The film

4-Lead foil sheet


06/25/18 07:00 Ossama El-Shall
black paper
surrounds film;
protects emulsion

film
single or double;
raised dot in one corner

lead foil
protects film from backscatter; reduces patient
exposure; strengthens packet; pattern identifies when
film is placed backwards (reversed)
06/25/18 07:00 Ossama El-Shall
Outer packet wrapping or envelope:

It is a soft plastic wrapper to protect the film


completely from the light and saliva.

It has two sides; white smooth side (tube side),


which has a raised bump on one corner, corresponds
to the identification dot on the film.

The other side (the label side) has a flap used to


open the film packet during processing.
It contains data about the number of films per
packet, and the film speed.
It also contains a circle of concave dot that
represent the identification dot of the film.
06/25/18 07:00 Ossama El-Shall
Outer film cover
Keeps out light and moisture; protects emulsion

plastic dot paper

# of films
in packet

#2 Tab #2 #1

06/25/18 07:00 Ossama El-Shall


Black paper film wrapping:

Are two black papers enclose the film


between them and further protect it
from light.

06/25/18 07:00 Ossama El-Shall


The film:
It is a double emulsion film; the
packet may contain one or two films.

At one of the film corners there is a


small raised dot (identification dot). It
used after film processing to
distinguish between the left and right
side of the patient mouth during
reading of radiograph (interpretation).
06/25/18 07:00 Ossama El-Shall
This identification dot or bump has a
convex and concave surfaces the convex
surface should face the rays while the
concave side being back to the film during
exposure.

Also it should be always away from any


anatomical landmarks to avoid misdiagnosed
as any pathologic lesion, so it should be
occlusally or incisally during exposure.

06/25/18 07:00 Ossama El-Shall


Lead foil sheet:

Placed back to the film away from


the smooth side of the film packet
(back side).

Its function is to absorb the back


scattered radiation and thus protects
the film from fogging.

06/25/18 07:00 Ossama El-Shall


It also adds to the rigidity of the
film packets.

It has a special pattern (herring


bone) stamped on the exposed
finished radiograph if the film is
exposed from the wrong side.(back
side film)

06/25/18 07:00 Ossama El-Shall


black paper
surrounds film;
protects emulsion

film
single or double;
raised dot in one corner

lead foil
protects film from backscatter; reduces patient
exposure; strengthens packet; pattern identifies when
film is placed backwards (reversed)
06/25/18 07:00 Ossama El-Shall
Backscatter
(scattered x-rays that go
“back” toward the film)

Primary x-rays
06/25/18 07:00 Ossama El-Shall
Scatter (secondary) x-rays
Reversed Films (back side film)

06/25/18 07:00 Ossama El-Shall


Types of intra-oral films

06/25/18 07:00 Ossama El-Shall


Intra-oral films

Intra-oral films can be classified mainly


according to their usage into

Periapical films

Bite-wing films

Occlusal films.

06/25/18 07:00 Ossama El-Shall


Also intra-oral films can classified
according their

* Speed

* Size

* Number of films per packet

* Whether the film packet is lead


backed or not.
06/25/18 07:00 Ossama El-Shall
Classification of intra-oral films
according to use

Periapical films Occlusal films

Bite wing films


06/25/18 07:00 Ossama El-Shall
Periapical Film

Periapical pathology

Apical pathology
Periodontal evaluation internal
resorption
Caries detection
Endodontic treatment

caries
06/25/18 07:00 Ossama El-Shall
Periapical films
It is the most frequently used intra-oral
view, which shows the entire tooth and
surrounding structure on the film.

There are three basic sizes for Periapical


films,
No. 0 or child film 22x35mm.
No. 1 or narrow adult 27x54mm.
No. 2, or standard adult film 31x41mm.

Periapical films used to exam the following:


06/25/18 07:00 Ossama El-Shall
I-Enamel:

1-Normally appears as a Radiopaque


structure.

2-Caries of the enamel: which appears as a


radiolucent area.

3-Enamel hypoplasia: appears as a


radiolucent area surrounded with radio-
opaque margin.

4-Amilogenesis imperfecta: all the enamel


appears as radiolucent area.

5-Congenital syphilis: Hutchinson’s incisors;


appears as v-shaped radiolucent area
surrounded by radio-opacity.

06/25/18 07:00 Ossama El-Shall


II-Dentin:

1-Normally appears as a Radiopaque structure

-2Caries of the dentin; appears as a v-


shaped radiolucent area.

3-Dentinogenesis imperfecta: dentin appears


as a radiolucent area surrounded by faint
radio-opaque margin

4-Dense in dente: appears as a radio-opaque


structure within the tooth surrounded by
radiolucent margin.

5- Internal resorption: radiolucent lines on


the apex or lateral side of the root dentin.

06/25/18 07:00 Ossama El-Shall


III-Pulp:

1-Normally appears as a
radiolucent area within the
tooth.

2-Calcification of the pulp: appears


as a localized area of radiopacity
= pulp stone. If it generalized it
appears as a generalized
radioopacity of the pulp
chamber.

3-Shell tooth : appears as a wide


pulp chamber.
06/25/18 07:00 Ossama El-Shall
IV-Cementum:

1-Normally it cannot be differentiated from the


dentin.

2-Hypercementosis: appears as Radiopaque


areas cover the cementum line.

3-Cementoma: appears at the apex of the tooth


as a radiolucent area in its early stages and
converted into a Radiopaque area at its
terminal stages.
06/25/18 07:00 Ossama El-Shall
V-Periodontal ligament space:

1-Normally appears as a
radiolucent line surround the
root surface

2-Narrowing of it as a result
of an oeteoblastic process
e.g. scleroderma

3-Widening of the space as


results of osteolytic process
e.g. osteolytic osteoma, .
06/25/18 07:00 Ossama El-Shall
VI-Lamina dura:

-Appears as Radiopaque clear


continues band covers the
alveolar bone ie. lining the
socket and cover the crest
of the crest of alveolar
bone (crestal lamina dura).

-Discontinuities of lamina
dura indicate pathological
changes.
06/25/18 07:00 Ossama El-Shall
VII-Alveolar bone:

Bone resorption either horizontal or


vertical.

06/25/18 07:00 Ossama El-Shall


Bite wing films
These films often have a paper tab projecting
from the middle of the film, on which the
patient bites to support the film. This tab is
not visualized and does not interfere with the
diagnostic quality of the image.
It used to record the coronal portions of
maxillary and mandibular teeth in one image.
The apices of the teeth are not shown.
It used for the following:

06/25/18 07:00 Ossama El-Shall


Bitewing Film

Interproximal Caries
Alveolar Bone Involvement
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Overhanging amalgam filling

06/25/18 07:00 Ossama El-Shall


1. Detection of initial proximal caries.
2. Detection proximal overhanging margins of
fillings and crowns.
3. Approximate estimation of the size of the
pulp chamber and pulp horns.
4. Detection of initial interproximal crestal
alveolar bone resorption indicating
periodontal disease.
5. Determination of the position of permanent
forming teeth in relation to deciduous
ones.
6. Determination of any proximal calculus
formation.
06/25/18 07:00 Ossama El-Shall
Detection of proximal caries by bite wing
radiographs compare to Periapical
radiograph

06/25/18 07:00 Ossama El-Shall


Occlusal films

Occlusal films are use to radiographically


clarify the anatomical structures and
the pathological conditions of the
maxilla or mandible in the bucco-lingual
dimension.

Occlusal films may use for the following


purposes:
06/25/18 07:00 Ossama El-Shall
Occlusal Film
Identify large lesions
Locate bucco-lingually
Developing anterior teeth
Imaging trismus patients

06/25/18 07:00 Ossama El-Shall


1. Obtaining gross views for the jaws in the
bucco-lingual dimension.
2. Detection location and extent of fractures.
3. Detection of the bucco-lingual direction of
impactions and supernumerary teeth.
4. Detection of bucco-lingual direction of
displaced fracture.
5. Detection of salivary gland or duct stone
especially in the mandible.
6. Localization of foreign bodies such as
broken needle.
7. Determination of the shape of dental
arches.
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Classification of intra-oral films
according to the speed

Film speed (sensitivity) can be


defined as the efficiency by which a film
can respond to an X-ray exposure,

i.e; a fast film requires low exposure


time to produce a standard density
image, while a slow film requires longer
time of exposure to produce the same
standard quality.

06/25/18 07:00 Ossama El-Shall


or it refers to the amount of radiation
required to produce a radiograph of
standard density.

Intra-oral films vary in speed, fast


films need less X-radiation and using
such films routinely plays a major role in
the field of radiation protection.

06/25/18 07:00 Ossama El-Shall


Factors affecting film speed

1-Whether the film is coated only on one side


with the silver halide grains (slow films) or on
both sides (medium and fast films)

2-The size of the silver halide grains, the


larger the size, the more sensitive the film.

06/25/18 07:00 Ossama El-Shall


 The speed of dental X-ray films is expressed
in a letter form.

 Speed groups are A, B, C, D, E and F

 A being the slowest film and each subsequent


group being approximately twice as fast as
the preceding group to give a final image of
the same object with the same density.

 This mean that; for example: E-speed film


requires one half the exposure time of D-
speed film.
06/25/18 07:00 Ossama El-Shall
Groups A & B are called slow films (regular).

Group C is called medium speed (radiatized).

Groups D & E are called high speed films (ultra-


speed and ecta-speed respectively).

Groups D-speed films and E-speed films are the


most common intra-oral film in every day’s use.

Kodak introduced E-speed plus film, this film


provides the superior image quality of D-speed film
at a reduced radiation exposure.

06/25/18 07:00 Ossama El-Shall


Classification of intra-oral films
according to size:
Periapical and bitewing film comes in three sizes:

0 For small children (about 22 X 35mm)

1 Which is relatively narrow and used for anterior


projections (about 24 X 40mm)

2 The standard film used for adults (about 32 X


41mm(

06/25/18 07:00 Ossama El-Shall


Classification of intra-oral films
.according to number of films per packets
Usually intra-oral films supply in packets
containing one film. Some film packets
include 2 films instead of 1.

This may be helpful for record keeping,


research purposes, teaching purposes,
medico-legal aspects or if it is meant to
control the density of each of the 2 films in
a different way during processing.

06/25/18 07:00 Ossama El-Shall


Film Processing

06/25/18 07:00 Ossama El-Shall


Processing

It is a chemical treatment, which is


applied to the Exposed film to convert the
invisible latent image to visible image from
which useful diagnostic data can be
obtained

06/25/18 07:00 Ossama El-Shall


Latent image formation
1. After film exposure, the silver halide molecules in the emulsion
that become exposed will absorb the X-ray and undergo ionized.

2. As a result of this ionization; minute amounts of metallic silver


are formed on crystal surface & bromide is liberated.

3. The degree of ionization within the crystals depends upon the


amount of exposure received (latent image).

4. The image remains within the emulsion till changed into silver
image by chemical processing.

5. In definition, the processing of the film is the process of


changing of the latent image into a visible image from which
useful diagnosis can be obtained.
06/25/18 07:00 Ossama El-Shall
Latent Image
Air/soft tissue Bone Amalgam/Metal
Many x-rays Fewer x-rays Few, if any, x-rays
penetrate and ionize penetrate and not as penetrate; silver
many silver halide many silver halide halide crystals not
crystals crystals are exposed exposed

06/25/18 07:00 Ossama El-Shall


Chemistry of processing
There are five major steps of chemical
processing:

1- Developing,
2- Rinsing.
3- Fixation.
4- washing.
5- drying.
06/25/18 07:00 Ossama El-Shall
1-Developing
Developer solution treats the exposed grains (ionized). Developer
solution has affinity to react with bromide part of the crystal
leaving the black reduced silver grains. It consists of five
elements:

1-Reducing agent: It converts the exposed silver crystals into


black metallic silver. It consists of Metol and Hydroquinone.
2-Activator: Sodium Carbonate; it swells and softens the
emulsion gelatin and provide alkalinity for the reducing
agent.
3-Restrainer: K. Bromide; it slow down rate of development of
unexposed crystals, so it restrain the reducing agent from
making the film fogged appears .
4-Preservative agent: Sodium sulphate; it prevent oxidization.
5-Water as dissolving agents.
06/25/18 07:00 Ossama El-Shall
Developing
Crystal centers converted to black
metallic silver

Air/soft tissue Bone Amalgam/metal

06/25/18 07:00 Ossama El-Shall


Developing (continued)
Entire crystal converted to
black metallic silver

Air/soft tissue Bone Amalgam/gold

06/25/18 07:00 Ossama El-Shall


2-Rinsing
With fresh water in order to
1- Neutralize the alkalinity of the developer
solution

2- To stop the developer action

3- Remove the remnants of developer solution


from the film
06/25/18 07:00 Ossama El-Shall
3-Fixation
It removes the unexposed undeveloped silver bromide
granules and hardens the gelatin. It consists of:
Clearing agent: Aluminum thiosulfate, it clear the
unexposed silver bromides.
Acidifier: Acetic acid, to provide required acidity to
neutralize the developer alkalinity.
Hardener: Aluminum chloride, to shrinks and
hardens the gelatin.
Preservative: Sodium sulphate: it maintains the
chemical balance of fixer chemicals.
Water as a solvent.
06/25/18 07:00 Ossama El-Shall
Fixing
Unexposed crystals removed
from film

Air/soft tissue Bone Amalgam/metal

06/25/18 07:00 Ossama El-Shall


4-Washing: with water to remove all the
residual processing chemicals.

5-Drying: with air or dryer to makes the film


finally ready for interpretation and
mounting, and facilitates film handling
with lesser mechanical damage.

06/25/18 07:00 Ossama El-Shall


Latent Image
Air/soft tissue Bone Amalgam/Metal
Many x-rays Fewer x-rays Few, if any, x-rays
penetrate and ionize penetrate and not as penetrate; silver
many silver halide many silver halide halide crystals not
crystals crystals are exposed exposed

06/25/18 07:00 Ossama El-Shall


Developing
Crystal centers converted to black
metallic silver

Air/soft tissue Bone Amalgam/metal

06/25/18 07:00 Ossama El-Shall


Developing (continued)
Entire crystal converted to
black metallic silver

Air/soft tissue Bone Amalgam/gold

06/25/18 07:00 Ossama El-Shall


Fixing
Unexposed crystals removed
from film

Air/soft tissue Bone Amalgam/metal

06/25/18 07:00 Ossama El-Shall


Methods of processing.
1. Fixed time and temperature. (Manual)
2. Visual method. (Manual)
3. Automatic processing:
4. Polaroid land radiography.
5. Inject able intra-oral films.
6. Self-processing solutions contained intra-
oral films.
7. Film less dental radiographic tech.
06/25/18 07:00 Ossama El-Shall
1-Fixed time and temperature.
1- It is a reliable and standardized method
2- The optimal temp. is 20
3- The higher temp. the less time required and vice
versa

4- the fixed times for each step are:


a- 5min developing
b-15-20 sec. for rinsing
c-10min. Fixation
d-20 sec. washing
06/25/18 07:00 Ossama El-Shall
2-Visual method.
1. Films are immersed in developer and
removed every now and then to be
checked on safe light till image is visible

2. Then rinsed and fixed

3. It is not standardized method as it


depends mainly on human factors
06/25/18 07:00 Ossama El-Shall
3-Automatic processing

Automatic processor is a special machine, which


can perform all the steps of processing of both
extra-oral and intra-oral films until the dry
radiograph is obtained in about 5 minutes.

The film is opened manually in a light tight


compartment of the machine and then placed in its
place to be automatically carried by the rollers of
the machine from one step to the other.

06/25/18 07:00 Ossama El-Shall


Advantages of automatic processor:
1-Rapid and easy method
2-Standardization of processing.
3-No need for dark room and its equipments.

Disadvantages of automatic processor:


1-Highly expensive.
2-Need for regular maintenance
3-Need minimum amounts of films per day
4-High temperature of machine tends to produce
chemical fog in the radiograph and rapid
deteriorates the strength of the solutions.
06/25/18 07:00 Ossama El-Shall
Automatic Processor

Drying
Elements

Film Film
Entry
Exit

Developing Water Fixing


06/25/18 07:00 Ossama El-Shall
Solution Rinse
Solution
y er
dr

x er
fi

n s e
r ri
t e
wa
er
l o p
v e s
de i lm
t f
r
in se
06/25/18 07:00 Ossama El-Shall
Daylight Loader
06/25/18 07:00 Ossama El-Shall
4-Polaroid land radiography.
Extra-oral films could be made using an emulsion on
a paper backing instead of the usual film base.

A special cassette and screen are used during film


exposure by conventional dental x-ray machine.

It required more exposure time but processing is a


one step dry method, only 10 sec. carried out in a
special electric small table top unit.
06/25/18 07:00 Ossama El-Shall
5-Injectable intra-oral films.
In these types of processing, the processing solutions are
respectively injected into the closed film packed which is
supplied with an inject able sits. As processing takes place
inside the packet, such film packets must have no lead foil
or black paper folds.
Advantage of inject able intra-oral films:
1-Easy and rapid method.
2-No need for the dark room.
Disadvantage of this method:
1-Fogged image.
2-Need further fixation to avoid loosing details.

06/25/18 07:00 Ossama El-Shall


6-Self-processing solutions contained
intra-oral films.
These films contain 2 small packets attached to
the film packet. After exposure, they are
pulled one after one to pour first the developer
and then the fixer into the film packet. This
method has the same advantage and
disadvantage of the injection method.

06/25/18 07:00 Ossama El-Shall


The Dark Room
 Light tight (against light leakage).
 Both white light and safe light illumination: The white light is
used for cleaning the tanks and preparation of the solutions. The
safe light is used during opining film packets and processing.
 Safe light specifications.
 Coin on film test.
 Processing tanks.
 Running water source.
 Timer. Either stop watch or florescent.
 Thermometer.
 Dryer.
 Storage space.

06/25/18 07:00 Ossama El-Shall


Processing tanks

06/25/18 07:00 Ossama El-Shall


Films holder

06/25/18 07:00 Ossama El-Shall


Safelight Filters

Morlite GBX-2
D-speed Intraoral, Extraoral
(all films)

06/25/18 07:00 Ossama El-Shall


KODAK LED Safelight
© Eastman Kodak Company

Twice as much light


06/25/18 07:00 Ossama El-Shall
Safe lighting

06/25/18 07:00 Ossama El-Shall


Safelight Test
(Coin on film test)

Problem

Everything OK

06/25/18 07:00 Ossama El-Shall


Intra-Oral Radiographic
Techniques.

06/25/18 07:00 Ossama El-Shall


1. Techniques for Periapical radiographs.

2. Techniques for Bite-wing radiographs.

3. Techniques for Occlusal radiographs.

06/25/18 07:00 Ossama El-Shall


Periapical radiographic techniques.

Typical 14 Periapical film survey for adults

06/25/18 07:00 Ossama El-Shall


06/25/18 07:00 Ossama El-Shall
Typical 14 film survey for adults
The central rays is targeted onto the apex; depiction of the
alveolar crest is of only secondary importance.
06/25/18 07:00 Ossama El-Shall
Periodontal 14-film survey for adults
The central rays is targeted onto the alveolar crest; depiction
of the root apices is only of secondary importance.
06/25/18 07:00 Ossama El-Shall
Techniques for Periapical
radiography

Paralleling technique

Bisecting angel technique.

06/25/18 07:00 Ossama El-Shall


Paralleling technique
Right angle technique
Long cone technique

06/25/18 07:00 Ossama El-Shall


Paralleling technique

06/25/18 07:00 Ossama El-Shall


Head Position

Head position for the


paralleling technique is
not critical, since you will
be aligning the PID with
the ring.

06/25/18 07:00 Ossama El-Shall


correct incorrect
In the paralleling technique, the film is positioned in the mouth so
that the long axis of the film and the long axis of the tooth are
parallel. We can not see the long axes of the teeth but, in general,
all the teeth incline toward the middle of the head. Thus the
film/instrument will almost always be tipped slightly (up or down,
depending on the arch). In the illustration above right, the film is
placed straight up and down and is not parallel; the patient is
unable to close completely on the biteblock and the apices of the
teeth would not appear on the film.

06/25/18 07:00 Ossama El-Shall


Rinn XCP Paralleling Instruments

ANTERIOR POSTERIOR

06/25/18 07:00 Ossama El-Shall


06/25/18 07:00 Ossama El-Shall
?Why long cone
To prevent the magnification of the
image and the un-sharpness of the film
due to increasing the film object
distance

A parallel non-diverging x-ray beam is


required, this is achieved by increase
target film distance by using a long
cone (16inches)
06/25/18 07:00 Ossama El-Shall
Sharpness

Measures how well the details


(boundaries) of an object are reproduced
on a radiograph

Increased by:
Source-object distance
Object-film distance
Film crystal size
Motion will decrease sharpness

06/25/18 07:00 Ossama El-Shall


Magnification

Decreased by:
Source-object distance
Object-film distance

06/25/18 07:00 Ossama El-Shall


16” FFD image
Target
16” from film Target
8” from film 8” FFD image
Film
Increasing the distance from the target of the x-ray tube
(focal spot, focus) to the object (teeth/film) (FFD = focus-film
distance) will result in an increase in sharpness and a decrease in
magnification. This results when a longer PID (cone) is used.

Moving the film closer to the teeth will also increase sharpness
and decrease magnification.
06/25/18 07:00 Ossama El-Shall
Target-object-film relation.

target Object Film

06/25/18 07:00 Ossama El-Shall


8" FFD

12" FFD

Most newer x-ray machines have a recessed target


(away from the PID). This helps to increase the
focus-film distance (FFD), resulting in a sharper
image and less magnification without an increase in
the length of the PID (position indicating device). A
longer PID is effective, but it makes positioning the
tubehead more difficult.
06/25/18 07:00 Ossama El-Shall
Object-film distance small

bisecting
paralleling

06/25/18 07:00 Ossama El-Shall


Maxillary anterior region

Photograph and radiograph of the region

06/25/18 07:00 Ossama El-Shall


Maxillary anterior region

Film holder and positioning for maxillary anterior area

06/25/18 07:00 Ossama El-Shall


Maxillary Incisor

centered on contact between film placed far back in


central and lateral incisors patient’s mouth

06/25/18 07:00 Ossama El-Shall


Maxillary canine region

Photograph and radiograph of the region

06/25/18 07:00 Ossama El-Shall


Maxillary canine region

Film holder and positioning for maxillary canine area

06/25/18 07:00 Ossama El-Shall


Maxillary Canine

film placed against the opposite


film centered on canine side of the arch, far away from
the canine

06/25/18 07:00 Ossama El-Shall


Maxillary premolar region

06/25/18 07:00 Ossama El-Shall


Maxillary Premolar

film equidistant from lingual


front edge of film anterior to surfaces of teeth (red
middle of canine; approximately arrows); this opens contacts
centered on 2nd premolar between the teeth.

06/25/18 07:00 Ossama El-Shall


film in center of palate
Maxillary molar region

06/25/18 07:00 Ossama El-Shall


Maxillary Molar

film equidistant from lingual


film centered on
surfaces of teeth (red
second molar
arrows); this opens contacts
between the teeth.

06/25/18 07:00 Ossama El-Shall film in center of palate


Mandibular anterior region

Photograph and radiograph of the region

06/25/18 07:00 Ossama El-Shall


Mandibular anterior region

Film holder and positioning for mandibular anterior


area

06/25/18 07:00 Ossama El-Shall


Mandibular Incisor

film positioned away from


film centered on midline teeth, pushing tongue
back slightly

06/25/18 07:00 Ossama El-Shall


Mandibular canine region

Photograph and radiograph of the region

06/25/18 07:00 Ossama El-Shall


Mandibular canine region

Film holder and positioning for mandibular canine area

06/25/18 07:00 Ossama El-Shall


Mandibular Canine

film positioned away from


film centered on canine teeth, pushing tongue
back slightly

06/25/18 07:00 Ossama El-Shall


Mandibular premolar region

06/25/18 07:00 Ossama El-Shall


Mandibular Premolar

film equidistant from lingual


front edge of film anterior to surface of teeth (red
middle of canine; approximately arrows); film placed toward
centered on 2nd premolar center of mouth, displacing
tongue

06/25/18 07:00 Ossama El-Shall


Mandibular molar region

06/25/18 07:00 Ossama El-Shall


Mandibular Molar

centered on second molar film equidistant from lingual


surface of teeth; in this case the
film will usually contact lingual of
molars

06/25/18 07:00 Ossama El-Shall


Bisecting angel technique

06/25/18 07:00 Ossama El-Shall


Bisecting angel technique.

X-ray beam

X-ray beam perpendicular to bisecting line


06/25/18 07:00 Ossama El-Shall
Bisecting angel technique.

06/25/18 07:00 Ossama El-Shall


The film is positioned with the long axis vertical and the
dot-end of film extending ¼” beyond the incisal edge.
With the all-white side of film facing the teeth, the finger
pressure is applied at the cervical portion of the crown to
avoid film bending.
06/25/18 07:00 Ossama El-Shall
The film is positioned with the long axis horizontal and
the dot-end of film extending ¼” beyond the occlusal
surface. With the all-white side of film facing the teeth,
the finger pressure is applied at the cervical portion of
the crown to avoid film bending.
06/25/18 07:00 Ossama El-Shall
Film placement, as indicated above, is the same for maxilla or
mandible. The film is placed vertically for anterior teeth
(canine to canine) and horizontal for posterior teeth.
06/25/18 07:00 Ossama El-Shall
The film is held in the proper position using the
thumb (maxillary anterior, above left),
Index finger of opposite hand (all other areas,
above right).
06/25/18 07:00 Ossama El-Shall
Vertical angulations during
bisecting angle technique

Maxilla (+ve) Mandible(-ve)


Incisors: 45-55 25-15
Canines: 45-50 15-20
Premolars: 35-40 5-15
Molars: 25-30 0-5

06/25/18 07:00 Ossama El-Shall


Horizontal angulations during
bisecting angle technique

Central rays should be parallel to


interproximal surface of the teeth

Central rays should pass through the contact


area of the teeth.

06/25/18 07:00 Ossama El-Shall


06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Advantages of Bisecting Angle Technique
•More comfortable: because the film is placed in the
mouth at an angle to the long axis of the teeth, the film
doesn’t impinge on the tissues as much.

•A film holder, although available, is not needed. Patients


can hold the film in position using a finger.

•No anatomical restrictions: the film can be angled to


accommodate different anatomical situations using this
technique
06/25/18 07:00 Ossama El-Shall
:Anatomical Variations

Anatomical situations which might require


:using the bisecting angle technique are
a shallow palate

a large palatal tours

a shallow or tender floor of the mouth

a short lingual frenum (tongue-tie)


06/25/18 07:00 Ossama El-Shall
Disadvantages of Bisecting Angle Technique

•More distortion: because the film and teeth are at an


angle to each other (not parallel) the images will be
distorted.

•Difficult to position x-ray beam: because a film holder is


often not used it is difficult to visualize where the x-ray
beam should be directed.

•Film less stable: using finger retention, the film has more
chance of moving during placement
06/25/18 07:00 Ossama El-Shall
Distortion

In the bisecting technique, the long axis of the tooth


is not parallel with the long axis of the film.
This results in a distortion of the image produced
using this technique.
In the left radiograph below, the buccal roots appear
much shorter than the palatal root, even though in the
actual tooth the lengths are not that much different. In
the other radiograph taken with the paralleling
technique, the lengths are projected in their proper
relationship (minimal distortion).
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Techniques for Bite-wing
radiography

06/25/18 07:00 Ossama El-Shall


Diagram of correct film position and central rays
targeting in bite-wing film

The paper extension from the film packet must not be


pulled too much. The central ray is targeted through
either the maxillary second premolar or the first
permanent molar.
06/25/18 07:00 Ossama El-Shall
Bitewing Head Position

The head should be positioned so that the maxillary


arch is parallel to the floor, both side-to-side and
front-to-back, when using bitewing tabs.
06/25/18 07:00 Ossama El-Shall
Bitewing Film Placement

Front edge anterior to Film centered on second


middle of mandibular molar (if 3rd molars are
canine (approximately erupted; otherwise center
centered on 2 nd on contact between 1 st
and
06/25/18 07:00premolar) Ossama El-Shall 2nd molar).
The stick-on bitewing tab is always centered top-to-
bottom with the film oriented horizontally (see picture
above). The tab is placed on the Clinasept cover on
the all-white side of the film. When some teeth are
missing, the tab may be placed more anteriorly or
posteriorly to allow maximum contact with the teeth
that are present.
06/25/18 07:00 Ossama El-Shall
The film is placed in the mouth between the
teeth and the tongue. Hold on to the tab and
instruct the patient to close slowly and
completely.
06/25/18 07:00 Ossama El-Shall
10°

positioning guide

The vertical angulation


is always set at +10
degrees (the tubehead
is pointing downward).

06/25/18 07:00 Ossama El-Shall


correct incorrect
The horizontal angulation is adjusted so that a line
connecting the front and back edge of the PID (yellow line
above) is parallel with a line connecting the buccal surfaces
of the premolars and molars (green line above). Instruct the
patient to open their lips so that you can see the buccal
surface (see next slide). The front edge of the PID should
be ¼” anterior to the front edge of the film.
06/25/18 07:00 Ossama El-Shall
Patient opening lips (“smiling with teeth
together”) to allow visualization of buccal
surface of posterior teeth.
06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall
Techniques for Occlusal
radiography

06/25/18 07:00 Ossama El-Shall


Maxillary Topographical Occlusal
Mandibular Topographical Occlusal

Maxillary Vertex Occlusal

Mandibular Cross-Sectional Occlusal

Posterior Oblique Maxillary Occlusal

Posterior Oblique Mandibular Occlusal


Modified Oblique Posterior Mandibular Occlusal

06/25/18 07:00 Ossama El-Shall


Occlusal Film
-Identify large lesions
-Determine bucco-lingual location
-View developing anterior dentition
-Image patients with trismus (if
panorama not available)

06/25/18 07:00 Ossama El-Shall


Head Position
Maxillary occlusal: Maxilla parallel to floor
Mandibular occlusal: Mandible perpendicular
to floor
Film Position
Centered on area of interest
All-white side facing x-ray tube
Patient bites gently on film

Exposure Settings
Normal Maxillary = PA/ BW
Mandibular = PA/BW
True Maxillary = 4X PA/BW
06/25/18 07:00 Ossama El-Shall
X-ray Beam Position
Centered on area of interest
Vertical angulations (see below)

06/25/18 07:00 Ossama El-Shall


Thank you all for listening

Dr. Ossama El-Shall

E-mail address: oelshall@hotmail.com

06/25/18 07:00 Ossama El-Shall


Believe in yourself,
for if you don’t believe
in yourself, it will be
hard for others to
believe in you

06/25/18 07:00 Ossama El-Shall


06/25/18 07:00 Ossama El-Shall
06/25/18 07:00 Ossama El-Shall

You might also like