What is Shopping Mall?

Travelator(Moving Walkway) Elevator


A shopping mall is a modern, chiefly North Travelator is a slow moving
Escalator With 30 degree= 1.732xstorey height
With 35 degree=1.428xstorey height
American, term for a form of shopping precinct conveyor mechanism that An escalator is a type of An elevator is a
vertical transportation that
type
moves
of

or shopping center, in which one or more transport people across a vertical transportation in people or goods between floors of a
horizontal or inclined plan the form of a moving building, vessel, or other structure.
buildings form a complex of shops representing over a short or medium staircase which carries
merchandisers with interconnecting walkways distance. people between floors
that enable customers to walk from unit to unit. Maximum inclined angle of a building.
Angle of inclination is
Corridors and Passageways must not exceed 18 degree
either 30 or 35 degree.
• Where stairways discharge through corridors and
passageways, the height of corridors and passageways shall
be not less than 2.4 m.
• All means of exit including staircases lifts lobbies and
corridors shall be adequately ventilated.
• Internal staircase minimum width shall be 2.0m in all Load 400 630 1000
group of building. Pressurization of Staircases (Protected Capacity
Escape Routes) a 1100 1100 1100
• Pressurization is a method adopted for protected escape
b 950 1400 2100
routes against ingress of smoke, especially in high-rise
buildings. c 1800 1800 1800
•In pressurization, air is injected into the staircases, lobbies d 1500 2100 2600
or corridors, to raise their pressure slightly above the
e 800 800 800
pressure in adjacent parts of the building.
• As a result, ingress of smoke or toxic gases into the escape
routes will be prevented.
Parking Space Footpath
Life Safety (General Exit Requirement) For car, the minimum parking space
• Obstruction free for the convenience of all
to be 3mx6m when individual
• A exit may be doorway; corridor passageways to an internal or users.
parking and 2.75mx5m when
external staircase or horizontal landing. • Height of the footpath not to be more than
common parking space is required
• Lifts and escalator shall not be considered as exits. 150mm from the road level.
Space for two wheeler to be not less
• Exits shall be clearly visible and the route to reach the exits • Change in level of footpath should be made
than 1.25mx1m
shall be clearly marked and signs posted to guide the clearly visible.
occupants of the floor concerned • Width of the footpath should be 1800mm
• The maximum distance of travel from any point to an exit or and minimum clear unobstructed path
entrance to the mall shall not exceed 60m. should be 1200mm.

Column Spacing Often used spaces are 6-9m(20-30ft


Ramps • Street furniture should be placed outside the
path of travel.
For vehicles- 1:10
max) with the last most flexible. For people- 1:12-14
Tactile Paving for Visually Impaired
Clear Height These vary from 3-4.5m or more, with For Handicaps- 1:16-20
Width of ramp leading to
3.5m a good average. Above this clear height, there must be
basement should not be less
adequate space for air conditioning ducts, recessed lights, than 4m.
structural system etc. Most wheelchair
Railing The railing height is generally considered to be requires a space of 2.5 m
taken in the range of between 1m-1.5m sq. to turn around

Shopping Mall Literature Study Page No. 1


Mercantile Buildings Chilled Beam
These shall include any building or part of a building,
which is used as shop, stores, market, for display and
sale of merchandise, either wholesale or retail
These buildings shall be further sub divided as
follows:
Sub Division F1- Shops, Stores, Departmental Stores
Market with area upto 500sqmt.
Sub Division F2- F1- Shops, Stores, Departmental
Stores Market with area more than 500sqmt
Sub Division F3- Underground Shopping Centres.

Duct System
Low Pressure Systems
Velocity <10m/s, static pressure,5cm HO (g)
Medium Pressure System
Velocity<10m/s, static pressure<15cm HO(g)
High Pressure Systems
Velocity>10m/s, static pressure 15,p,25cm HO(g).
Recommended air velocities depend mainly on the
application and the noise criteria
Residences: 3m/s to 5m/s
Theatres: 4m/s to 6.5m/s
Restaurants: 7.5m/s to 10m/s

Fire Protection Sprinkler Pictorial Signs


System
• Automatic Sprinkler System
• Stand Pipe Systems
• Fire Extinguishers and Cabinets
• Special Fire Protection Systems
- Carbon Dioxide System - Dry
Chemical System -Halon System
-Foam Extinguishing System
-Grease Exhaust Hood Fire
Protection System

Shopping Mall Literature Study Page No.2