EE8411 - ELECTRICAL

MACHINES LABORATORY - II

Department of EEE, PMC Tech, Hosur


EE8411 - ELECTRICAL MACHINES LABORATORY - II

• Year/Sem - II/IV
• No. of Students - 53
• No. of Batches - 11
• Strength of Batch - 05
• List of Experiments - 11
• Cycle -I Experiments - 05
• Cycle -II Experiments - 06

Department of EEE, PMC Tech, Hosur


OBJECTIVES & OUTCOMES OF EM-II LAB

• OBJECTIVES:
To expose the students to the operation of Alternator, Synchronous motor
and induction motors and give them experimental skill.
• OUTCOMES:
Ability to understand and analyze the voltage regulation of alternator
using EMF and MMF methods
Ability to analyze the characteristics of synchronous motor using V and
Inverted V curves
Ability to understand the various characteristics of Induction Motor
Ability to acquire knowledge on separation of losses in Induction Motor

Department of EEE, PMC Tech, Hosur


SAFETY PRECAUTIONS
• Avoid loose wires, cables, and connections.
• Assume any exposed metal is live with electricity unless otherwise verified.
• Only make changes to the experimental setup when the circuit power is turned
off and all power sources read zero voltage and zero current, as applicable.
• Never bypass fuses or MCB’s.
• Make sure that all DC power supplies, AC sources, and other power sources start
from a zero voltage and zero current output or as directed in an experiment.
• Turn off all equipment before leaving the lab once an experiment concludes.
• Every Student should know the locations and operating procedures of all safety
equipment including, First AID KIT (s) and Fire extinguisher.
• Electrical equipment and connections should not be handled with wet hands, nor
should they be used after liquid has been spilled on it.

Department of EEE, PMC Tech, Hosur


LIST OF EXPERIMENTS
1. Regulation of three phase alternator by EMF and MMF methods.
2. Regulation of three phase alternator by ZPF and ASA methods.
3. Regulation of three phase salient pole alternator by slip test.
4. Measurements of negative sequence and zero sequence impedance of
alternators.
5. V and Inverted V curves of Three Phase Synchronous Motor.
6. Load test on three-phase induction motor.
7. No load and blocked rotor tests on three-phase induction motor
(Determination of equivalent circuit parameters).
8. Separation of No-load losses of three-phase induction motor.
9. Load test on single-phase induction motor.
10. No load and blocked rotor test on single-phase induction motor.
11. Study of Induction motor Starters
Department of EEE, PMC Tech, Hosur
CYCLE - I
1. Regulation of three phase alternator by EMF and MMF methods.
2. Regulation of three phase alternator by ZPF and ASA methods.
3. Regulation of three phase salient pole alternator by slip test.
4. Measurements of negative sequence and zero sequence impedance of
alternators.
5. V and Inverted V curves of Three Phase Synchronous Motor.

Department of EEE, PMC Tech, Hosur


CYCLE - II
1. Load test on three-phase induction motor.
2. No load and blocked rotor tests on three-phase induction motor
(Determination of equivalent circuit parameters).
3. Separation of No-load losses of three-phase induction motor.
4. Load test on single-phase induction motor.
5. No load and blocked rotor test on single-phase induction motor.
6. Study of Induction motor Starters

Department of EEE, PMC Tech, Hosur


SPECIFICATIONS & REQUIREMENTS OF EM-II LAB
DC Ammeter - (0-2A), (0-10A), (0-20A)
DC Voltmeter - (0-300V)
AC Ammeter - (0-5A), (0-10A), (0-20A)
AC Voltmeter - (0-150V), (0-300V), (0-600V)
Wattmeter - UPF, LPF
Tachometer - Digital Type
Rheostat - 360 Ω 1.5A, 280 Ω 1.2 A
Starter - Three Point Starter
DOL Starter,
Star Delta Starter,
Autotransformer Starter
Multimeter - Digital Type

Department of EEE, PMC Tech, Hosur


LOAD TEST ON THREE PHASE INDUCTION MOTOR

AIM:
To draw the performance characteristics of 3-phase squirrel cage
induction motor by conducting load test.

Department of EEE, PMC Tech, Hosur


LOAD TEST ON THREE PHASE INDUCTION MOTOR

APPARATUS REQUIRED:
S.No Name of the Apparatus Range Type Quantity

1 Ammeter (0-10A) MI 1

2 Voltmeter (0-600V) MI 1

3 Wattmeter 600V, 10 A UPF 2

4 Tachometer - Digital 1

5 DOL Starter - - 1

6 Connecting Wires - - As Per Required

Department of EEE, PMC Tech, Hosur


LOAD TEST ON THREE PHASE INDUCTION MOTOR

RESULT:
Thus the load test on 3-phase squirrel cage induction motor has been
conducted and their performance characteristics were plotted.