You are on page 1of 11

PARKING REQUIREMENTS

• ACCORDING TO NBC 2 ECS IS PROVIDED IN SHOPPING CENTRES FOR


100MSQ OF BUILT UP AREA

• A RATIO OF 5 AND 6 CAR SPACES PER 1000SQFT FOR RETAIL SHOPS.


PARKING SHOULD BE WITHIN 30M FROM THE MAIN ENTERANCE.
• TWO ACCESIBLE CAR PARKINGS 3600 MMX5000MM WITH ALL
NECESSARY SIGNAGES.
• FOR CINEMAS AND THEATRES 1 CAR PARKING FOR
10 PEOPLE.
• For car, the minimum parking space to be 3 m x 6 m when
individual parking space is required and 2.75 m x 5 m when
common parking space is required.
• Space for scooter/two wheeler and bicycle to be not less than 1.25
msq and 1.00 msq respectively.
Source : scribd
Minimum clear height of 2.5 m should be provided for the ease of movement of car.
The widths of the ramps should usually be no less than 3.5m for a single
ramp and 7m for a double ramp
Slope of these ramps should be 1:12
Minimum level difference between two cars should be atleast 2.4m
FIRE AND SAFETY
• FIRE DOOR SHOULD BE WITHIN 30M FROM THE FARTHEST POINT OF THE MALL IT CAN
BE
• INCREASED BY 50 PERCENT WHEN PROPER ADEQUATE AMOUNT OF FIRE HYDRANT
SYSTEMS ARE INSTALLED.
• ALL THE INTERNAL WALL SHOULD PROVIDE FIRE RESISTANCE UPTO 60 MINUTES.
• ALL THE FIRE EXIT DOORS AND WALLS SHOULD PROVIDE RESISTANCE FROM FIRE UPTO
120MINUTES.
• One 9 liter water expelling extinguisher or ABC 5 kg/6 kg fire extinguisher, for every 200
m2 of floor area or part there of with minimum of two extinguishers per compartment
or floor of the building. The extinguishers should be so located as to be available within
15 m radius.
• SMOKE DETECTORS ONE PER 400MSQ OF FLOOR AREA.
• NO STAIRCASE SHOULD BE INCLINED AT ANGLE MORE THAN 45DEGRESS.
• SATIRCASE SHOULD HAVE FLIGHT OF 1250M WITH ATLEAST 250MM WIDE
• TREAD AND 190MM WIDE AND BALUSTER WITH HANDRAIL HEIGHT NOT
EXCEEDING 1000MM

Source :nbc 2005 part 4 is code 2190


NO OF EXITS NO OF DOOR WIDTH
PEOPLE PEOPLE
500 2 50 800MM
2000 4 110 900MM
4000 5 220 1100MM
7000 6 220+ +5MM PER
PERSON
11000 7
16000 8
Source : nbc 2005
WATER AND TOILETS REQUIREMENTS
Sl. No. Sanitary Unit / Fittings For Personnel

1. Water closet One for every 25 persons or part thereof exceeding 15


(including employees and customers). For female personnel
1 for every 20 persons

2. Drinking Water Fountain One for every 100 person with a minimum of one on each
floor.

3. Wash Basin One for every 25 persons

4. Urinals 1 for 7-20 persons


2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 add at the rate of 3%; For over 200 persons
add at the rate of 2.5%.

5. Cleaners’ Sink One per floor minimum, preferably in or adjacent to sanitary


rooms.

source: model building bye laws