Professional Documents
Culture Documents
Level 1
Introduction to Product Data
Sheets
Module 108
Learning Objectives
When you finish this module, you will be able to do
the following :
Elite (CMF)
F-Series
H-Series
T-Series
Micro Motion ELITE® Series
• Highest Flow and Rangeability
• Highest Density Performance
• Unsurpassed Immunity to Field Effects such as
Pressure, Temperature, and Vibration
• Secondary Pressure Containment is Standard
• Nominal Line Sizes from 1/8” to 6” (3 to 150 mm)
Models : CMF010, CMF025, CMF050, CMF100,
CMF200, CMF300, CMF400
BRIEF SPECIFICATIONS :
Liquid Accuracy +/-0.10% of Flow Rate (0.05% of Rate Optional)
Gas Accuracy +/-0.35% of Flow Rate (Legacy +/-0.5%)
Density Accuracy +/-0.0005 g/cc (0.0002 gm/cc Optional)
Wetted Parts 316L Stainless Steel or Nickel Alloy
Temp. Rating -240 to 204 C
Pressure Rating 100 Bars for SS and 148 Bars for HY Sensors
Micro Motion F-Series
• Flow Accuracy to 0.2% on Liquids and 0.5% on
Gases, with 0.15% and 0.1% Accuracy Option
Available on Liquids with MVD Transmitters
• Optional Secondary Containment
• Nominal Line Sizes from ¼” to 3” (6 to 75 mm)
Models : F025, F050, F100, F200, F300
BRIEF SPECIFICATIONS :
Flow Accuracy +/-0.20% of Flow Rate
Gas Accuracy +/-0.50% of Flow Rate (Legacy +/-0.7%)
Density Accuracy +/-0.002 g/cc (+/-0.001g/cc Optional)
Wetted Parts 316L Stainless Steel / Hast - C for F300H
Temperature Rating -100 to 180 C
Pressure Rating - 100 Bars / High Pressure Models also Available
(F025P, F050P and F300P)
Micro Motion H-Series
• Flow Accuracy to 0.15% on Liquids and 0.5% on Gases
• 3-A Authorized & EHEDG Approved
• 32 Ra Internal Surface Finish is Std (15 Ra Optional)
• Smooth, Easy-to-Clean Exterior Finish
• Optional Secondary Containment
• Nominal Line Sizes from ¼” to 3” (6 to 75 mm)
Models : H025, H050, H100, H200
BRIEF SPECIFICATIONS :
Flow Accuracy +/-0.15% of Flow Rate (option +/- 0.10% of flow rate)
Gas Accuracy +/-0.50% of Flow Rate
Density Accuracy +/-0.002 g/cc (option +/- 0.001 g/cc)
Wetted Parts 316L Stainless Steel
Temperature Rating -100 to 180 C
Pressure Rating 100 Bars
Micro Motion T-Series
• Best Single Straight -Tube Design
• 3-A Authorized and EHEDG Approved
• Improved Surface Finish Option 20 Ra or Better for
Hygienic Applications (Standard is 32 Ra)
• Optional Display
• Secondary Pressure Containment of 50 Bars is Standard
• Nominal Line Sizes from 1/4” to 2” (6 to 50 mm)
Models : T025, T050, T075, T100, T150
BRIEF SPECIFICATIONS :
Flow Accuracy +/-0.15% of Flow Rate
Density Accuracy +/-0.002 g/cc
Wetted Parts Titanium ASTM Grade 9
Temperature Rating -50 to 150º C
Pressure Rating 100 Bars
Review Questions :
Name the “High Precision, Multivariable MMI Sensors” ?
What are 4-5 Main Attributes of an Elite Sensor ?
Which Sensor Series are Supplied with Standard Secondary
Containment ? Which have Optional Secondary Containment ?
Which Sensor Line(s) Meet All of the Requirements of 3-A and
EHEDG ?
What are Model Base Model Numbers of F-Series & H-Series
Sensors ?
Which Sensor Line has a Base Accuracy for Liquids of 0.1% ?
What is the Density Accuracy of All CMF Sensors ?
Micro Motion General
Purpose, Flow-Only
Sensor
R- Series
Micro Motion R-Series
• Simple, Reliable Flowmeter
• Optional Integrally-Mounted Electronics
and Display
• Nominal Line Sizes from 1/4” to 3” (6 to 75 mm)
Models : R025, R050, R100, R200
BRIEF SPECIFICATIONS :
– CMF010P, F025P,
F300P, R025P, DH150
and DH300
BRIEF SPECIFICATIONS :
Flow Accuracy ±0.5% of Batch from 1 to 100 kg/min
Max Std Volume Flow Rate 4444 SCFM (7550 Nm3/hr)
170 lb/min
BRIEF SPECIFICATIONS :
– Gas Density
Micro Motion Solartron
Tube Densitometers
Chemical
7846 Hastelloy
resistance
7847
– Hygienic Densitometer
– Stainless steel 316 tube material
– Base Accuracy ±0.00035 g/cc over density range 0.6 – 1.2 g/cc
– Base Accuracy ±0.00010 g/cc with UKAS calibration (limited temp
range – 30oC)
Micro Motion Solartron
Tube Densitometers Specifications
7835
– Ni-span C tube material
– Base Accuracy ±0.00015 g/cc
– Base Accuracy ±0.00010 g/cc with UKAS calibration
7845
– Stainless steel 316L tube material
– Base Accuracy ±0.00035 g/cc
– Base Accuracy ±0.00010 g/cc with UKAS calibration
(limited temp range – 30oC)
Micro Motion Solartron Tube
Densitometers Specifications Summary
Parameter Type 7835 Type 7845/46/47
Accuracy ± 0.00015 g/cc ± 0.00035 g/cc
Density range 0-3 g/cc 0-3 g/cc
Factory calibrated range 0.3-1.1 g/cc 0.6-1.6 g/cc
Repeatability 0.00002 g/cc 0.0001 g/cc
Temperature effect ± 0.000005 g/cc/°C ± 0.00005 g/cc/°C
(± 0.000003 g/cc/°F) (± 0.00003 g/cc/°F)
Max operating pressure 150 bar 100 bar (1450 psi) - 7845
or flange limit (2175 psi) 50 bar (725 psi) – 7846
20 bar (290 psi) - 7847
Temperature range -50 to +110 °C 50 to +160 °C
(-58 to +230 °F) (-58 to +320 °F)
Wetted parts Ni-span C & 316L SS 316L SS & Hast C (7846)
Micro Motion Solartron Densitometer
- Short & Long Stem Forks
Long Stem
Short Stem w/ Flange
Short Stem
w/ Cone Fitting w/ Flange
Comparison of Performance
- w/ Short & Long Tines
7826 7828
Long Tines Short Tines
500 cp 20000 cp
Viscosity Limit Viscosity Limit
7828 7826 More tolerant to Less tolerant to
entrained gas in entrained gas in
the liquid the liquid
Standard or
Advanced
7828 Advanced
Amplifier Only !
w/PTFE Coating Amplifier
Fork Wetted Materials
316 L SS
304 SS
Hastelloy B
Hastelloy C
Monel 400
Titanium
Zirconium (in the works)
New Opportunity
MMI Proprietary/Confidential
Board Meeting – 1/11/06
Coating and Electro Polish
7828
w/PTFE Coated
Tines
Micro Motion Fork Densitometer
Specifications (Short Stem)
Long Tines Short Tines
Other Options/Techniques :
– Purge Fittings
– Rupture Disks
Pressure De-rating
Above certain temperatures, the pressure rating
of a sensor (case and housing) decreases.
Pressure Effect
– Very Predictable
– Can Compensate
– No Effect on Small Meters
Pressure and Temperature Effects
Non-Wetted Parts
– Housing
– Junction Box
– Core Processor
Fittings
– Tube Compression
– NPT Cajon Union Fitting
– Sanitary Fitting (Tri-Clamp Compatible)
Fitting and Flange Options - contd
Other
– Grayloc High Pressure Hubs
– Wafer Style
– CEQ
Examples
– DT065H
– CMF010P
– CMF025L
– CMF300A
Product Description – cont’d
Densitometer Model Selection Example
7828 A C A A C B L B B Z
Process Connections, Case Options
Process Connections
– End Connection Choice
– Three Digit Code
– Example : 323 – ¼” NPT Female CAJON Size 4 VCO Fitting
Case Options
– Describes the case
• Standard Case
• Compact Case (F-Series Only)
• Hygenic Case
• Purge Fittings
• Rupture Disks
• Containment Options
Electronics Interface
Core Processor
– Extended or Not
– Aluminum or Stainless Housing
Junction Box
– Extended or Not
MVD Solo
– Extended or Not
– Aluminum or Stainless Housing
Integral Transmitter
– Not Available for Elite
Conduit Connections, Approvals
Conduit Connections
– NPT or M20 (½” NPT for MVD, ¾” NPT for J-box)
– Glands are Optional
Approvals
– Many Available – Discussed in Product Approval
Module
– MVD Solo with Approvals includes a Barrier
Language and Options
Language
Future Option
Measurement Application Software
– Petroleum Measurement Software - Only used for
MVD Solo
Factory Options
– Z for Standard
– X for CEQ
– R for Restocked
Rosemount 8800D
Vortex Meter
General Sensor Specifications
Rosemount 8800D Vortex Meters
8800DF (Flanged) , 8800DW (Wafer) Vortex
Reliable in Tough Applications
Designed for Reliability
• Eliminates Impulse Lines
• Only Vortex on the Market with No Ports or Gaskets
• All-Cast, Non-Clog Design
• Vibration Immunity with ADSP Filters & Mass-Balanced Sensor
Wafer
• Fast Filter Optimization with ‘Auto Filter Adjust’
Flanged • Replaceable Sensor Without Breaking Process Seals
• Simple, ‘In the Field” Troubleshooting through Device Diagnostics
Why a Thermocouple ?
– 1/8” diameter temperature sensor is required to use shedder bar
as thermowell
– Thermocouples have been shown to have better performance
and reliability in small diameters.
– This is not true for larger diameters (¼” diameter) where RTDs
will be more accurate
Why Type N ?
– Type-N special limits gets us the same level of accuracy as small
diameter RTD with less drift
• Type N is ni-cor
• Not a base-metal thermocouple (Type J or K), which makes it less
susceptible to drift.
Rosemount 8800D MV Vortex Offering
Materials
– Stainless Steel
Line Sizes
– Flanged >=2”
– Reducer >=3”
– Not available on Dual or Wafer
Flange Ratings
– ANSI Class 150-600, DIN PN 10-100, JIS 10K-40K
HART or HART w/ Pulse
Called out by MTA option code in 8800D model
structure
Lead-time is 15-30 working days for most
configurations
Remote Mount and FOUNDATION fieldbus not
available at initial release
Rosemount 8800D Vortex Meter Line Sizes
Pressure Limits
– Flanged, Reducer & Dual : Rated to ASME B16.5 for classes
150, 300, 600 and 900
– Wafer : Rated to ASME B16.5 for classes 150, 300 and 600
Performance Specs
Accuracy
– Includes Linearity, Hysteresis and Repeatability
– For Liquids : 0.65% of Rate
• For 6” to 12” Reducer Vortex, Accuracy is 1.0% of Rate
Temperature
– ± 2.2°F (1.2°C) or 0.4% of Reading (in °C), whichever
is Greater
8800D-W-020-S-A1-N-1-D-1-I5-M5-Q4
Cal Cert
LCD Indicator
FM I/S
4-20 mA
¼” NPT Conduit Entry
Std Sensor
ANSI 150#RF
SST Wetted Parts
2” Size
Wafer Design
8700 Series Magmeter
General Sensor Specifications
8705 Flanged Flowtube
8707 Hi-Signal Flowtube
General Sensor Specifications
8705/8707 Flowtubes
Available Sizes
– 8705 Standard : ½” to 36”
– 8707 High Signal : 3” to 36”
Measurement Electrodes
– Code SA : 316L SSt
– Code HA : Hastelloy C-276
– Code TA : Tantalum
– Code PA : 90% Platinum & 10% Iridium
– Code NA : Titanium
Flanges
– Carbon Steel/304 SSt : ANSI 150#, 300#, 600# and 900#
– Carbon Steel/304 SSt : DIN, PN 10, 16, 25 and 40
– Note : For DIN flanges refer to price book as not all sizes are
available
Temperature Limits
Temperature Limit is Liner-Dependent
– Teflon Liner : -29 ºC to 177 ºC
– Tefzel Liner : -29 ºC to 149 ºC
– PFA Liner : -29ºC to 177 ºC
– Polyurethane Liner : -18ºC to 60 ºC
– Neoprene Liner : -18 ºC to 85 ºC
– Linatex Liner : -18 ºC to 70 ºC
Flow Tube Pressure vs Temperature Limits
Conductivity Requirement
– For 8705 : min 5 microseimens
– For 8707 with 8712H : min 50 microseimens
– When using code _E : min 100 microseimens
8705/8707 Ordering Information
8705-T-SA-020-C1-W0-N0-G1-B3
Measurement Electrodes
– Code SA : 316L sst
– Code HA : Hastelloy C-276
– Code TA : Tantalum
– Code PA : 90% Platinum & 10% Iridium
– Code NA : Titanium
Conductivity
– Min of 5 microsiemens/cm
Pressure Limits
– With Tefzel Lining : Full vacuum to 51 bar (15mm to 200mm)
Full vacuum to 19.6 bar (4mm and 8mm)
– With Teflon Lining : Consult Factory
8711 Ordering Information
8705-T-SA-020-U-1-N0-G1
Sanitary/Hygienic Approvals :
– 3-A Authorized
– EHEDG Certification PFA Liner and
SS Meter Body
Rosemount 8721 Hygienic Mag
FDA Approved Materials for Product
Rosemount 8721 Sensor
Contact Surfaces : with Remote Terminal
– PFA Liner Junction Box
– “Piggable”
8721-A-SA-020-U-A-1-N0-AH
Electro Polish to 20 Ra