Professional Documents
Culture Documents
2. Growth Rate
1ൗ
𝑛
𝑃2015
𝐺𝑟𝑜𝑤𝑡ℎ 𝑟𝑎𝑡𝑒 = −1
𝑃2010
1ൗ
3,317 5
𝐺𝑟𝑜𝑤𝑡ℎ 𝑟𝑎𝑡𝑒 = −1
3,084
𝐺𝑟𝑜𝑤𝑡ℎ 𝑟𝑎𝑡𝑒 = 0.0146732 ≈ 1.467%
2. Projection
𝑃2029 = 𝑃2015 (1 + 𝐺. 𝑅)𝑛
𝑃2029 = 3,317(1 + 0.0146732)14
𝑃2029 = 4067.355 ≈ 4067
Demand Projection
1. Domestic Use(per capita) for no more than 250m from source – 50 LCPD
2. Projection
𝑄2029 = 𝑝𝑒𝑟 𝑐𝑎𝑝𝑖𝑡𝑎 𝑥 𝑝𝑜𝑝𝑢𝑙𝑎𝑡𝑖𝑜𝑛
𝑄2029 = 50 𝐿𝐶𝑃𝐷 𝑥 4067
𝑄2029 = 203,350 𝐿𝐶𝑃𝐷
PNSDW 2017
Parameter Maximum Allowable Level
1. Taste No Objectionable Taste
2. Odor No Objectionable Odor
3. Color (Apparent) 10 CU
4. Turbidity 5 NTU
5. Alluminum (Al) 0.2 mg/L
6. Chloride (Cl) 250 mg/L
7. Copper (Cu) 1 mg/L
8. Total Hardness 300 mg/L
9. Hydrogen Sulfide (H2S) 0.05 mg/L
10. Iron (Fe) 1 mg/L
11. pH 6.5-8.5
12. Sodium (Na) 200 mg/L
13. Sulfate (S04 2-) 250 mg/L
14. Total Dissolved Solids 600 mg/L
15. Zinc (Zn) 5 mg/L
DESIGN CONCEPT
WATER SUPPLY SYSTEM
• By improving the water supply system to level II, the projected water demand in the
next 10 years must be accommodated.
• The water supply system must also use piping systems to transport water from the
source to the storage tank.
• From the storage tank, the water will be distributed to each household, ranging from
4-6 households.
WATER PURIFICATION SYSTEM
• Raw water from the hand pump will be purified to remove contaminants and to meet
the standards and laws of potable water.
Filtration