Seminario Técnico

Regional
LG Electronics

STANDARD Inverter 5ta Generación


Seminario Técnico Regional

1. Presentación LG Electronics
2. Mercado en Colombia
3. LGMV WIFI
4. Multi Standard
5. Multi V V
POR FAVOR APAGAR
SU CELULAR 6. LG Chiller Colombia
LG ELECTRONICSLG LIDER TECNOLÓGICO
SOLUCIÓN TOTAL
Panel Solar Single CAC

Comercial Display

Manejadoras especiales AUTOMATIZACION


(High efficiency AHU) BacNet - Lonworks

RAC

Chiller
Multi V V
La más completa línea de producto Aire Acondicionado

Unidades Manejadoras
de Aire con refrigerante
variable

RAC Multi Multi


Single Standard
Inverter Art Inverter Inverter Single
Cool Package Multi V
Inverter V Inverter Condensad Multi V
Windows o por agua Condensado
por Aire

Enfriadores De Agua
Scroll, Tornillos condensados por
Equipos producidos en fábricas LG aire, Tornillos condensados por agua,
Scroll Inverter, centrífugos,
absorciones.
Aire Acondicionado y puntos clave en la Construcción

Sustentabilidad del sitio

Innovación en Diseño & Eficiencia en


Consideraciones Agua
Regionales

Eficiencia
Calidad del Aire Interior Energética

Selección de
Materiales
Aire Acondicionado y puntos clave en la Construcción

Calidad del Aire Interior


- Temperatura / Humedad – Control Individual
- Flujo de Aire
- Calidad del Aire/Renovación
- Nivel de Ruido

Eficiencia Energética
Innovación en Diseño y
- Máximo Rendimiento
Consideraciones Regionales
- Control lineal de la demanda
- Uso racional del espacio
- Medición Consumo
- Flexibilidad de Instalación
- Operación Confiable
- Inversión Inicial Óptima
- Servicio
-Automatización
AIRE COMMERCIAL
ACONDICIONADO DISPLAY

CLIENTE

PANEL
SOLAR
UN EQUIPO DE TRABAJO

ECO AMIGABLE
AHORRO DE ENERGÍA FIELES A SUS
ALTA RENTABILIDAD CLIENTES

SOPORTE
INNOVACIÓN
TÉCNICO
TECNOLÓGICA
COMERCIAL

IDEAS CREATIVAS DE
NEGOCIO
LG B2B Group
PRESIDENCIA LG ELECTRONICS

CARTERA CONTABILIDAD

LOGÍSTICA SERVICIO

COMMERCIAL DISPLAY AIRE ACONDICIONADO ENERGIA

GRUPO DE VENTAS
IT CD SOPORTE
PROYECTOS REGIONALES

TOTAL LG COLOMBIA 250 PERSONAS 67 CENTROS DE SERVICIO AUTORIZADO


LG B2B Group
San Andres (1 ASD)

Medellín (6 ASD)

Cartagena (7 ASD)

Barranquilla (4 ASD)

Cúcuta (1 ASD)

Bucaramanga (9 ASD)

Pereira(1 ASD)

Bogotá(23 ASD)

Tulua (1 ASD)

Villavicencio (1 ASD)

Neiva(4 ASD)

Cali (4 ASD)

Buenaventura (1 ASD)
CAPACITACIÓN

SOPORTE TECNICO
PERMANENTE

LOGISTICA

APOYO
FINANCIERO
ENTRENAMIENTO GRATUITO PARA 1400 PERSONAS AL AÑO

AIRE ACONDICIONADO
• PRINCIPIOS BÁSICOS DE AIRE ACONDICIONADO
• PRINCIPIOS BÁSICOS
• INSTALACIÓN CHILLER Y VRF
• DISEÑO Y SELECCIÓN DE CHILLER Y VRF
• MULT V SYNC Y WATER - SELECCIÓN E INSTALACIÓN
• SOLUCIÓN DE FALLAS CHILLER Y VRF.
• DIAGNÓSTICO FALLAS Y LGMV
• CONTROLES, SELECCIÓN E INSTALACIÓN.
• CHILLER – COMPONENTES, OPERACIÓN,
MANTENIMIENTO

PANEL SOLAR
• PRINCIPIOS BÁSICOS PANEL SOLAR
• DISEÑO Y SELECCIÓN PANEL SOLAR
• INSTALACIÓN, PUESTA EN MARCHA Y
MANTENIMIENTO DE PANEL SOLAR.
LGMV WIFI
Multi V H/P Multi V IV
(Heat Pump)
Multi V III
Multi V H/R Multi V IV HR
(Heat Recovery)
Multi V III HR
Multi V Water Water IV

Water II

Water S (mini)
Multi V S MultiV S Residence

MultiV S

Mini

Single Package Single Package

Single & Multi Pressure Control

Temperature Control
MÁS DE 600 TÉCNICOS CON LGMV WIFI
STANDARD
Mantén la apariencia de tu hogar

Sin Multi Split Con Multi Split


Multi Standard Line up
Heatpump
Indoor Units 18kBtu 24kBtu 36kBtu
9+9k ○
9+12k ○
2 rooms
12+12k ○
18+18k ○
9+9+9k ○
3 rooms 9+9+12k ○
12+12+12k ○
Características Multi Split
Outdoor Unit
El motor de ventilador BLDC de LG ofrece un ahorro de energía adicional de hasta 40%
a bajas velocidades.

BLDC Motor

80

60
20%
Efficiency (%)

AC Motor Rotor Stator


40
40%
Rotor
20 Permitir alta eficiencia a través del
uso de 12 imanes de neodimio.

0
200 400 600 600 800 1,000
Stator
Motor Speed [RPM]
Eficiencia mejorada a baja velocidad
por bobina concentrada.
• LG Internal test result
La ruta optimizada del intercambiador de calor y la distribución equitativa mejoraron la
eficiencia del ciclo hasta en un 5%.
Convencional Nuevo

 Por la perturbación del flujo, ocurre la pérdida de energía.  Sin perturbación de flujo, la pérdida de energía se reduce.
 La distribución desigual hace que la eficiencia de la transferencia de  La distribución equitativa hace que la transferencia de calor sea
calor se reduzca debido al exceso de flujo y falta de flujo más eficiente y confiable.

Distribucion Igual

Lack flow
Over flow

Flow disturbance
Straight flow
without loss
A través de la tecnología de control de corriente máxima, es posible ahorrar la energía y
el costo de operación. Es útil para evitar cargos de electricidad excesivos.

 Al limitar la corriente máxima de funcionamiento, el aire


Peak acondicionado puede evitar el funcionamiento en el nivel
máximo de corriente.
Running Current

 Esta función puede reducir el costo de energía durante los


Step 1 períodos pico que la carga eléctrica es costosa
Energy Saving
Limited [Como configurar los dip switch]
Current
Step 2
1 Full Load consumption : 2.5 kW
Cut-off
2 Max power consumption : 1.9 kW

3 Max power consumption : 1.7 kW

Time
• 7.0kW model

* Al usar el control de corriente máxima, la capacidad de enfriamiento puede ser reducida..


Para ahorrar energía de la operación, controle automáticamente la temperatura del refrigerante
según la temperatura exterior.
24, 36K Outdoor only - To : Outdoor temperature
Conventional Smart Load Control - A is the indoor unit coil temperature

To=35℃ condition

A℃ A℃
Refrigerants Refrigerants

Full load Full load

To=20℃ condition

A℃ A+α℃
Refrigerants Refrigerants
Over cooling Mild cooling

Full load Part load


A B 30

25

pressure loss (mmAq)


20

15

10

Conventional
5

A B
0
0 10 20 30
Time (min.)
"+" shape

Pressure Loss
Pressure (Pa) A B
(A-B)
Conventional 25.5 2.0 23.5
Wide Louver
Plus Fin Wide Louver
19.5 1.8 17.7
Plus Fin

• LG Internal test result


Las partes del compresor giratorio Twin Inverter se han mejorado para permitir una mayor vida útil.

Reduce la entrada de aceite al aumentar la Reducción de la pérdida de succión y


longitud del tubo de descarga de aceite, que mejora de la recolección de aceite a
queda suficiente aceite dentro del través de la optimización de la trayectoria
compresor para evitar la abrasión del de succión.
compresor.

Recubrimiento de superficie de
El área de la ruta del aceite excelente propiedad de
mejora en más del 50% al resistencia a la abrasión en la
aumentar la cavidad extra del paleta y el cigüeñal.
estator. Debido a esto, se reduce
el valor calórico del motor,
mejorando la función de
enfriamiento de la bobina del Desequilibrio de desplazamiento del
estator. rotor de la parte superior e inferior
en la rotación del rotor del eje.
La vibración y el ruido se reducen.
Es posible un funcionamiento más rápido y más confiable desde la tecnología de control de
presión.
Conventional New

Temperature Pressure
Temperature Sensor + Sensor
Sensor

Pressure +
Temperature Control
Outlet Temp.( ℃)

Outlet Temp.( ℃)
40℃
Temperature Control
Temperature Control

12℃
Pressure +
30% Temperature Control 44%

2 3 Time (min.) 3 5 Time (min.)


• LG Internal test result
Presión Manométrica Temp. Ebullición
TABLA DE
PSI Kpa °C
REFRIGERANTE R-410A
25 170 -30.02
33 230 -25.01
44 300 -19.99
55 380 -15.01
68 470 -10.12
1 KPa = 0,145 PSI 84 580 -4.89
1 PSI = 6,9 KPa 102 700 0.13
120 830 4.96
142 980 9.94
167 1150 14.98
196 1350 20.29
225 1550 25.08
261 1800 30.47
290 2000 34.42
334 2300 39.82
377 2600 44.73
428 2950 49.95
493 3400 56.01
537 3700 59.70
609 4200 65.34
682 4700 70.17

29
ABSORCIÓN DE CALOR

Temperatura ENERGIA CALORICA ABSORBIDA PARA 1 Kg DE AGUA.


ºC / ºF

110 / 230

SENSIBLE
100 / 212
LATENTE

FASE DIFASICA FASE


FASE LIQUIDA GAS
(LIQUIDO + VAPOR)

SENSIBLE
Sobrecalentado
0 / 32
SOLIDO
LATENTE

-10/14 SENSIBLE

17 144 180 970 Energía


BTU
TEMPERATURA DE
EBULLICION
30
TEMPERATURA DE EBULLICIÓN

Presión Atmosférica y Punto de Ebullición del agua


La Presión Afecta el Punto de Ebullición

A una Presión de 20 PSI


El agua Hierve a 125.5 °C

Puntos de ebullición a presión atmosférica

…………………
AGUA 100°C

…………………
HFC-134A -26.1°C 0m – 101 KPa: COSTA………….100 °C

960m – 91 KPa: B/MANGA………97 °C


…………………
HCFC-22 -40,8°C
2600m – 74,6 KPa: BOGOTÁ………92 °C

8800m – 26 KPa: EVEREST……….66 °C

Aumento de Presión -> Aumento punto de Ebullición


Disminución de Presión -> Disminución punto de Ebullición
31
Unidad
Evaporadora / Interior
Refrig. Vapor

Refrig. Líquido

32
En un serpentín Aire a 10 °C Gas
5 °C
830 Kpa

Liquido Gas
5 °C 8 °C
830 Kpa 830 Kpa
Refrigerante R410A

Calor del Sol … 12000 btu Aire a 26 °C


Iluminación … 68 btu/m2

Computador … 400 btu

Carga humana … 400 btu

33
COMPONENTES BÁSICOS DE UN SISTEMA DE AIRE ACONDICIONADO

• Condensador Líquido Gas


Aire a 35 °C
45 °C 45 °C
2700 Kpa 2700 Kpa Gas
Líquido 85 °C
42 °C 2700 Kpa
2700 Kpa 392 PSI
392 PSI

Aire a 30 °C

VALVULA DE Aire
EXPANSIÓN • Compresor
Aire a 10 °C

Sensor de
Baja Presión
Liquido
5 °C
830 Kpa Gas
120 PSI Refrigerante R410A
8 °C
793 Kpa
°C 115 PSI
Aire a 26 34
• Evaporador
El nuevo ventilador axial de la unidad exterior ayuda a reducir los niveles de ruido y a mejorar la
eficiencia.

La separación de flujo ocurre más atrás de la cuchilla Reducción de la longitud de la capa límite
y reduce el vórtice  flujo separado↓, Caudal↑  Perdida por Fricción ↓, Caudal ↑
Flow friction loss
Separation point

flow velocity distribution

[Without rib] [With rib(mogul)]


* Flujo separado: flujo separado de la superficie por
gradiente de presión adversa

Fije el borde de ataque de la cuchilla


Frente al lado del Hub Rigidez↑
Los instaladores pueden verificar si el cable de transmisión se ha conectado correctamente utilizando la
función de verificación de error de cableado. La función de verificación de error de cableado puede reducir el
tiempo necesario para verificar los errores del cable de transmisión.

[LED Result]
• If the wiring is correct,
the Green LED will light up.

1
• If the wiring is wrong, display as below
- Red LED : Piping Number
- Green LED : Wiring Number (Room)
1
Ex)
2 2 If the Red LED blinks twice and the Green LED
blinks 3 times, 2nd pipe is connected to 3rd room
3
Error

Piping wiring
3

* Dip Switch Setting


Si hay algún problema, sin desmontar el chasis, los ingenieros o técnicos pueden verificar rápidamente el código de error
del aire acondicionado a través del indicador de error de 7 segmentos.
18, 24K Outdoor only

7-segment error indicator

• Displayed
Error code
LGMV ayuda a los ingenieros y/o técnicos a inspeccionar y monitorear las unidades de aire acondicionado
fácilmente.

IDU & ODU


Information
PC based LGMV
(for service)
Cycle & Valves

Operation information
Sensors & Electricity

LGMV module
Cycle Diagram
(for service)

Actuator Information

Cycle View
Multi Split Feature
Indoor Unit (Wall Mounted Unit Only)
Durabilit Perfect Health
Fast cooling & heating Comfort
y Care
Dual Auto Quick &
Gold Fin Fast Fast Protection Cleaning Comfort
Jet Cool Easy
Cooling Heating Filter Air Installation

Standard
Ez
Cleaning
Filter

1Step
Detachable
Grille
Survival Rate Bacteria
100

18 hours.
75

99.9%
50 Sterilization

25

0 18
Time(hours)
Bacteria Odor Mold
elimination elimination elimination
The Gold Fin™ coating protects the surface of the heat exchanger from unnecessary
wear and corrosion.
The cool air flow reaches all the corners of the room, keeping the space cool and
comfortable.
LG air conditioners provide optimized high-speed air flow, which can cool rooms faster
while delivering cool air evenly in every direction.
By reducing the manpower and time required for installation, it is now possible to
install in a shorter period of time.
Inverter 5ta Generación
1. Dual Sensing Control
- Advanced energy saving under the low humidity condition
* High sensible cooling with Dual Sensing SLC → improved SEER & comfort

2. Ultimate Inverter Compressor


- LG’s 5th Gen compressor with a new bearing (PEEK material)

3. Large Capacity Outdoor Unit


3 main communication contents
- Reduced installation space over 20HP unit
in MULTI V 5 standard proposal
- 1unit 26HP / Combination max 96HP
- With 4 sided coil & new fan with biomimetic technology

4. Upgraded Coil Protection


- With Ocean black fin
5 main* communication contents
5. Enhanced heating in MULTI V 5 movie & catalogue
- With humidity sensor (delay frost)

6. Type Changer Over VRF (Heat pump & Heat recovery)


- One model for heat pump and heat recovery

7. Upgraded Low Noise Operation / Indoor Setting (SLC, Low noise, Continuous heating)
- Indoor low noise setting with standard III remote controller anytime you want

8. Wide Operation Range


- Cooling (-15℃ ~ 48℃) / Heating (-25℃ ~ 18℃)
7.1 Dual Sensing Control

Dual Sensing Control Efficiency & Comfort


Designed for the Ultimate

MULTI V 5 can provide better comfort and save energy with a humidity sensor.

Unlike the conventional models that only sensed outdoor and indoor temperature, MULTI V 5 effectively senses
both humidity and temperature of outdoor and indoor environments.

 Smart Load Control  Comfort Cooling  Smart Heating


7.1 Dual Sensing Control
Multi V Super 5 changes dry and closed environment into the comfort and healthy work environment based on sensory temperature.

Temp. and humidity Detection


IDU sensors Indoor temperature and humidity

The temperature calculation for humidity


Setting a target temp. according to humidity

Cooling according to sensory temperature


Change into the comfort and healthy work environment

Control based on sensory temp.


7.1 Dual Sensing Control
Multi V Super 5 by utilizing a humidity sensor reduced energy consumption and make comfortable environment first time.

Controls by sensing
the indoor / outdoor
temp.

The result of
big data in weather center

10,000M$ 25% ↑
7.1 Dual Sensing Control
Why do we need dual sensing?
To operate energy saving and comfort cooling, humidity is considered with temperature.

[Cooling load according to temperature change] [Cooling load according to humidity change]

Latent heat load Latent heat load


Sensible heat load Sensible heat load

Actually required System


capacity
Cooling Load

Cooling Load
Conventional
Design point

25 oC 30oC 35 oC 30% 50% 70%


Temperature Relative Humidity

The load decreases depending on the outdoor temperature The amount of latent heat load changed according to the
decreased. humidity is considered.
 humidity sensing is required.

• Condition : Humidity 60%  Indoor 25oC Humidity 55% • Condition : Indoor 30oC  Indoor 25oC Humidity 55%
7.1 Dual Sensing Control
LG’s dual sensing solution
MULTI V 5 can do optimized energy saving operation through dual sensors.(Temperature & Humidity)

- LGE VRF : Dual Sensing

- Standard VRF : Single Sensing

Temperature sensor
real-time sensing to humidity as well as
temperature real-time sensing to humidity as well as
Humidity sensor
temperature
1-2. Dual Sensing Control

MULTI V 5 can save more energy through dual sensing control. (under the low humidity condition)
Outdoor unit (temp & humidity sensor) / Indoor (with standard III remote controller – temp & humidity sensor)

Indoor Outdoor
MULTI V 5 advanced functions
with dual sensing control

Smart
Comfort
Load Heating
Cooling
Control
Available in 17.March

Through the dual sensing (temp & humidity)


these 3 functions were upgraded.

* As we know, MULTI V IV has these 3 functions already.

Temperature Humidity Temperature Humidity


1-3. Dual Sensing Control Dual Sensing Smart Load Control

Smart Load Control Dual Sensing Smart Load Control


With Temperature Sensor With Temperature Sensor and Humidity Sensor

Low Humidity

High Humidity

Low Humidity

High Humidity
1-3. Dual Sensing Control Dual Sensing Smart Load Control

Dual Sensing
Smart Load Control
With Temperature Sensor and Humidity Sensor

■ MULTI V 5 26HP Cooling Efficiency


20℃ 25℃ 30℃ 35℃ ESEER Low Humidity

SLC
8.07 6.59 5.08 3.60 6.34
High Humidity
EER
100% 100% 100% 100% (100%)

10.75 8.19 5.10 3.60 7.62


SLC EER
133% 124% 101% 100% (120%)
Dual Sensing 8.27
11.33 8.90 5.72 4.25 Low Humidity
SLC EER
(Low Humidity) 140% 135% 113% 118% (130%) SLC
Dual Sensing High Humidity
10.22 7.85 4.97 3.24 7.31
SLC EER
(High Humidity) 127% 119% 98% 90% (115%)
* Low humidity : RH 30% ~ 50%, High humidity : RH 70% ~ 100%

■ MULTI V 5 26HP
SLC EER (Efficiency) improvement effect 33% 24% 1% 0%
(vs Non-SLC EER)

Dual Sensing SLC EER (Efficiency) improvement effect 27~40% 19~35% -2~13% -10~18%
(vs Non-SLC EER)
1-4. Dual Sensing Control Dual Sensing Comfort Cooling

Comfort Cooling Dual Sensing Comfort Cooling


With Indoor Temperature Sensor With Indoor Temperature Sensor and Humidity Sensor

Comfort Cooling Dual Sensing Comfort Cooling


Discharge Discharge
Temp. Temp.
Temp. only Temp. & Humidity sensing
Setting Setting
Temp. Temp.

Time Time
High humidity condition – Fixed target superheat
When (Tair- Ttarget) is getting smaller (no additional variation)
 Target superheat ↑ (Discharge air temp ↑) Std. humidity condition – Target superheat is changed
depends on Tair- Ttarget
Low humidity condition – Increase superheat target
compare to Std. humidity condition

■ Comparison : SLC vs Comfort cooling


SLC (Smart Load control) Comfort Cooling

Control logic Outdoor unit : low pressure control Indoor unit : superheat control

Setting Setting is needed Setting is needed

Function effect All indoor units are affected Individual setting is available for each IDUs
2-2. Ultimate Inverter Compressor
No changes compare to MV IV

Reliable Vapor Injection Technology


 Reliable high efficiency 2-stage compression
 Deliver more heat at lower temperatures

No changes compare to MV IV

Reliable HiPOR TM and Oil Level Sensing Technology

Changed - MULTI V 5 New technoloy


Enhanced Bearing Technology
 High lubricity PEEK bearing (Polyether ether ketone)
 Increased bearing performance in oil-less state

(Defect)
Friction coefficient
Aluminum Multi V IV Multi V 5
(50 sec) (240 sec) (275 sec)

Time

 Compact and less vibration


 Reduced bearing loading, Reduced vibration force

Changed - Increase operation range


High Efficiency in Full and Partial Load Condition
 Increased heating performance
 Lower turn down

Multi V IV

Multi V 5

10 15 20 120 150 165 Operation range (Hz)


10 ~ 165Hz
7.4 High Efficiency Inverter Compressor
Multi V Super 5 has high efficiency inverter scroll compressor with frequency range 10Hz~165Hz.

T.V.I (Twin Vapor Injection) Aero bearing


 World's first, high efficiency 3-stage compression  New applied high reliability aero bearings
 T.V.I Technology applied to improve heating performance and efficiency  High lubricity material
 Heating efficiency 10% improvement  Operation time increase at oil free state
 reliability improvement

Extended Compressor Speed Quick Oil Return


 Insufficient oil supply immediately
 Wide operating range from 10Hz to 165Hz
 oil supply time 120 seconds  Within 10 seconds
 When the load is high, Powerful performance
 Minimize part damage  Reliability improvement
 Down to 10Hz  Part load efficiency improvement
1st Generation 2nd Generation 3rd Generation 4th Generation 5th Generation

26HP
4.8HP + 6.8HP Inv. comp 6.8HP + 6.8HP Inv. comp

5 Generation Inverter
• • • • • New bearing with PEEK material
• • BLDC Inverter, VI, HiPORTM, Oil Sensor
• • range : 10Hz ~ 165Hz
2-4. Ultimate Inverter Compressor MV IV vs MV 5 comp

Reduce comp. size (20%), Reduce weight (16%), Increase power density (20%)

MULTI V IV MULTI V 5
Comparison
4th Comp. 5th Comp.

6.8 Std. Capacity (HP) 6.8

15 ~ 150 Operation range (Hz) 10 ~ 165

900 ~ 9,000 Operation speed (rpm) 600 ~ 9,900

1.7 ~ 17 Variable capacity (HP) 1.1 ~ 18.7

160 Frame Size (Φ, mm) 147

460 Height (mm) 440

38.0 Weight (kg) 32.0

FR160 PEEK
bearing
(Inner bearing) (Outer bearing)
Inner bearing Outer bearing
83 (@150Hz)
87 (@150Hz) (Max.) Noise level (dBA)
85 (@165Hz)

* MULTI V 5 4.8HP Comp : same height (440mm) & frame size (Φ,mm)

* Motor output density = (Max motor output / motor volume)


Sitios de Referencia

NEOMUNDO (Bucaramanga, Colombia) CODENSA CALLE 93 (Bogotá, Colombia)


AC Screw 320 RT/ 2017 AC Screw 280 RT / 2017

SIEGFRIED (Bogotá, Colombia)


AC Scroll 80RT / 2016
Sitios de Referencia

CDMB (Bucaramanga, Colombia) AEROPUERTO ALCARAVÁN (Yopal, Colombia)


AC Scroll 120 RT/ 2016
AC Scroll 120 RT / 2017

MOVICH HOTEL (Pereira, Colombia)


AC Scroll 120 RT / 2017

AEROPUERTO VAZQUEZ (Leticia, Colombia) AEROPUERTO PERALES (Ibagué , Colombia)


AC Scroll 280 RT/ 2017 AC Scroll 280 RT/ 2017
SCROLL INVERTER Internal Use Only

• •
HiPORTM Technology

+
By-Pass HiPORTM





SCROLL INVERTER
Características & Beneficios








*HMI : Human Machine Interface


SCROLL INVERTER
SCROLL INVERTER Internal Use Only

Inverter
120Hz
Inverter
120Hz
SCROLL INVERTER Internal Use Only

CAPACIDAD
(TR)
18 32 37 48 55 64 69 74 80 85 87 92 96 103 110 111 112 114 117 119 122 124 129 133 135 140 142 144 147 151 158 165 166 167 170

MÓDULOS 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4

18 TR ● ●

32 TR ● ●● ● ● ● ●● ● ●● ● ● ● ●●

37 TR ● ● ●● ● ● ●●● ● ●● ● ●● ● ● ● ●●● ●●

48 TR ● ● ● ●● ● ● ●● ● ● ●● ● ● ●●● ●● ● ● ●●

55 TR ● ● ● ● ●● ● ● ● ● ● ●● ●● ● ●● ●●● ● ●

CAPACIDAD
(TR)
172 174 177 179 181 184 190 192 195 197 199 202 206 213 220 221 222 225 227 229 232 234 236 239 240 243 245 247 250 252 254 257 261 268 275

MÓDULOS 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

18 TR
32 TR ● ●● ● ● ● ●● ● ● ● ●

37 TR ● ●● ● ● ●● ● ● ●●● ●● ● ● ●● ● ● ●● ● ● ●

48 TR ● ● ●●● ● ●●●● ● ●●● ●● ● ● ●● ● ●●●● ● ●●● ●●●●● ●● ● ●●●● ● ●●● ●● ●

55 TR ● ●● ● ●● ●● ●● ●● ●●● ● ●●● ●● ●●● ●●●● ●● ●● ● ●● ●● ●●● ● ●●● ●● ●●● ● ●●● ●●●● ●● ●●●● ●●● ●●●● ●●●●●

Vista
Vista Trasera
Frontal
18 275
RT RT
Conexiones independientes en
5 Módulos Básicos para Combinar : cada módulo garantizan la
confiabilidad del sistema

18 TR 32-37 TR 48-55 TR
37 TR 55 TR

92 TR
SCROLL INVERTER Internal Use Only
Modo Operación Silenciosa
SCROLL INVERTER
SCROLL INVERTER Internal Use Only
HMI Control Táctil



SCROLL INVERTER Internal Use Only
SCROLL INVERTER
SCROLL INVERTER

1 (l/min)  0,264 (GPM)


1 (GPM)  3.785 (l/min)
SCROLL INVERTER
SCROLL INVERTER
SCROLL INVERTER
SCROLL INVERTER

ACAH020*BTA
SCROLL INVERTER

ACAH040*BTA
SCROLL INVERTER

ACAH060*BTA
SCROLL INVERTER
SCROLL INVERTER
SCROLL INVERTER
SCROLL INVERTER
Maestra Esclava 1 Esclava 2
Air Conditioning and Energy Solution Company
03AHD/ADW SELECTION PROGRAM PERFORMANCE SUMMARY

PROJECT NAME:XXX
______________________________________________________________________________________________________

AIR HANDLER UNIT: 03ADB

TAG NAME: UMAW-5

Unit Size_________________________________________________ 17
Fan Type_________________________________________________ AIR FOIL
Fan Wheel Diameter_______________________________________ STANDARD
Fan Class_________________________________________________ II
Fan Application___________________________________________ Draw Thru
Orientation_______________________________________________ HORIZONTAL

Actual Airflow, CFM_______________________________________ 8560


Site Altitude, ft___________________________________________ 8360
Downstream Ext. Static, in wg______________________________ 0,42
Cooling Coil Static, in wg__________________________________ 1,00
Heating Coil Static, in wg__________________________________ 0,00
Other Losses, in wg_______________________________________ 0,00
Total Accessory Static, in wg_______________________________ 1,57
Total Static Pressure, in wg________________________________ 2,99
Calculated Fan RPM/Motor RPM____________________________ 2379/3600
Max RPM 3600
Fan BHP/Motor HP 6,8/10,0

Accessories: " CA

(1) MXB1 MIXING BOX 0,10


(1) FLT1- FILTROS 35% 2" Y 85% 4"**** 1,47

TOTAL 1,57

**** PARA ESTA SELECCIÓN SE SIMULARON FILTROS SUCIOS AL 100%.


SELECCIÓN CHILLER SCROLL

Ejemplo de Selección.

La capacidad Total requerida por las 5 AHU es de 853,31 MBtu, 171 GPM.
 Se selecciona el Enfriador que a las condiciones de operación, ofrezca la capacidad más cercana
por encima. En este caso, 918 MBtu, 172 GPM.
SELECCIÓN CHILLER SCROLL
SELECCIÓN CHILLER SCROLL
GRACIAS
Internal
Internal UseUse Only
Only
App. Dual Sensing Comfort Cooling
Without stopping, this function can maintain operation at mild cooling mode around the set temp.

Example)
Target superheat of each indoor unit
Room Temp.
Convenient (refer to humidity of indoor)
THM ON
Field adjustment , Step1: A=0, Step2: A=1, Step3: A=2
Setting Temp.
RH(%) 100~70 70~50 50~30 30~
THM OFF Tair-Ttarget Super Heat Temp variation(℃)

<-0.5 0 +2+A +3+A +4+A

Room Temp. Comfort Cooling -0.5≤&<0.5 0 +2+A +3+A +4+A

0.5≤&<1.5 0 +1+A +2+A +3+A

Step1 1.5≤&<2.5 0 +1 +2 +3

2.5≤&<3.5 0 0 +1 +2
Setting Temp.
3.5≤ 0 0 +1 +2
Standard
Room Temp. Comfort Cooling

Dual Sensing Comfort Cooling

Step2 Expand changing range by humidity


Setting Temp. * Priority : 1. Indoor humidity (Option)
* No refer to outdoor humidity
Room Temp. * No humidity sensor : Fixed standard mode (RH(%) : 70~50)
(same as Multi V IV comfort cooling condition)

Effect of Max. 3~5 ℃ increase of discharge air


Step3
(Super Heat Max. 5 ℃ )
Setting Temp.
Internal
Internal UseUse Only
Only
App. Dual Sensing SLC control
Variation of discharge air : - 1.7℃ ~ + 11.8℃
Dual Sensing Smart load control (Cooling) (≒ - 2℃ ~ + 12℃)
Weather dependent Range of α
(Dry & Web Bulb)
High humid Standard Low humid
3 step Start up operation Coil Temp.
(until 20 min) (℃) RH(%) 100~70 70~50 50~30 30~
Power /Standard /Smooth
Discharge Tair-Ttarget Target Coil Temp. variation(℃)
Changed by A+α
Temperature <-0.5 +0.4 +1.2 +2.0 +2.8
indoor load A+9
(Indoor unit) -0.5≤&<0.5 0 +0.8 +1.6 +2.4
실A+α Low humid
0.5≤&<1.5 -0.4 +0.4 +1.2 +2.0
A Standard 1.5≤&<2.5 -0.8 0 +0.8 +1.6
High humid 2.5≤&<3.5 -1.3 -0.4 +0.4 +1.2
3.5≤ -1.7 -0.8 0 +0.8
SLC Control 20 35 Out Air
(after 20 min) Temp.(℃) * Priority : 1. Indoor humidity (Option)
Non-SLC Control 2. Outdoor humidity (Default)
* No humidity sensor : Fixed standard mode
(Off-coil temp. = A) (same as Multi V IV)

+α(℃)

3
2
1
30~
0
50~30
-1 -0.5
0
-2 1 70~50
2
3 100~70
3.5