You are on page 1of 95

Fire detection and alarm systems

Polon-Alfa Spółka z ograniczoną odpowiedzialnością Sp.k.

● Year of establishment 1957


● Number of employees 200
● Legal Status partnership company
● Company profile professional electronics,
manufacturing and development of:
- fire detection and alarm systems,
- dosimetry instruments.
History

1957 Tele & Radio Communication Institute – Experimental Works in


Bydgoszcz was established
1962 Firm was submitted to new organisation:
Nuclear Engineering Equipment Office in Warsaw
1963 Intensive development of the factory was begun
1969 Change of organisation of the whole enterprise and its name to
United Factories for Nuclear Equipment POLON
1990 Independent State – owned Enterprise: Radiation Dosimetry
Instruments Factory POLON-ALFA was established
1995 Privatisation of the factory. Radiation Dosimetry Instruments Factory
POLON-ALFA Limited Liability Company was established
1998 Acquisition of ISO 9001 certificate
2002 Acquisition of NATO Commercial and Government Entity Code – NCAGE
2008 POLON-ALFA became part of AAT Holding Capital Group
Development of fire detection systems
1963 The first in Poland and THIRD in the world ionisation smoke detector

1971 The first complete fire detection system, based on series 100
control panels and series 10 detectors

1980 New generation of 30 series detectors, new universal control panel

1995 Introducing of addressable system for a huge buildings TELSAP

2001 First implementation of POLON 4000 system devices

2002 First polish, certified self-contained (home) smoke detector ADR-20

2006 Supplementation of POLON 4000 with wireless detectors

2012 Introduction of a new generation of series 6000 detectors

2015 Introducion of the POLON 6000 system


Designing of a new products

New products are designed by


well experienced and educated
engineers using CAD software.
Automatic assembly - preparing

The automatic process of laying of


soldering paste using up-to-date
automation.
Automatic assembly – SMD

Electronic printed boards are


assembled on a high effective
automations.
Automatic assembly - soldering

Lead-free soldering is made in an


automatic cycle in specialized soldering
furnaces.
Quality control

Ready made electronic printed


boards are checked on
a specialized optical
and dynamic testers.
Automatic assembly – protective coating

Protective coating of an electronic


printed boards is made on a very
precise automaton.
Possibility to manufacture of high
special versions of the products (for
premises, where very hard
environmental conditions appear).
Initial operation

All units are putted into initial


operation on a workplaces equipped
with specialized apparatus.
Final assembly

Ready made components are


placed into it’s housings and
than given to quality control
department.
Test fire chamber

Test fire chamber for testing of fire


detectors in real conditions according to
EN 54-7 standard (one of 3 in Poland, two
others are in certification bodies).
Tests in smoke tunnel

The sensitivity of detectors


isdetermined according to
EN 54-7 standard in smoke tunnel.
Heated aerosol of paraffin is used
as a smoke.
Electromagnetic interferences tests - EMI

Each unit is subjected to test on sensitivity to external and the level


of it’s internal interferences.
Manufacturing of moulds for plastic elements

Every mould for manufacture of


plastic elements are designed by
company technologists and made
using modern machines.
Performing of plastic elements

Plastic elements, including casings for


fire detectors are made using modern
injection moulding machines.
Detectors casings can be made in any
colour from RAL palette at choice.
Trainings and presentations

POLON-ALFA, in addition to regularly run


training courses for SSP installers, for 20
years organizing the largest Polish National
Workshops designed for a wide range of
professionals in fire protection.
Company’s products
Company’s products

• Fire detection and alarm systems


(conventional and addressable)
• Fire extinguishing systems controllers
• Universal control panel UCS 6000
System POLON 4000

● addressable, interactive
● for middle, huge and very huge objects
● from 2 x 64 up to 8 x 127 addresses
● basing on many low-profile fire detectors
● hierarchical for common protected areas
● flexible configuration for every object
● built-in short-circuit insulators
● co-operation with parallel indication terminal TSR 4000
● for control of automatic fire extinguishing procedure
(POLON 4500)
● for control of various fire protection systems (UCS 6000)
System POLON 4000

POLON 4100 POLON 4200


System POLON 4000

POLON 4900 POLON 4500


Line elements of POLON 4000
Fire detectors:
● ionization smoke DIO-4046, DIO-4043
● optical smoke DOR-4046, DOR-4043
● universal optical smoke DUR-4046, DUR-4043
● universal heat TUN-4046, TUN-4043
● universal optical smoke DUR-4047 (radio controlled)
● optical smoke and heat DOT-4046
● multi-sensor DUT-6046
● optical smoke and flame DPR-4046
Optical smoke detector DOR-4046, DOR-4043*
Limitations: dusty areas

Technical data:
● Current consumption from line < 150 µA
● Modes of operation 3 (settings of sensitivity)
● Test fires TF2 – TF5
● Max heigth of installation 12 m
● Operating temperature range from -25C to +55C

* For use ONLY with POLON 4100 and POLON 4200 control panel
Universal optical smoke detector DUR-4046, DUR-4043*
Limitations: dusty areas

Technical data:
● Current consumption from line < 150 µA
● Modes of operation 3 (settings of sensitivity)
● Test fires TF1 – TF5 and TF8 and TF9
● Max heigth of installation 12 m
● Operating temperature range from -25C to +55C

*The BLUE diode built-in.

* For use ONLY with POLON 4100 and POLON 4200 control panel
Universal heat detector TUN-4046, TUN-4043*
Main application:
The detector is to be treated as complementation of
fire alarm system and shall be used where regular
smoke detectors can not be installed, i.e. kitchens etc.

Limitations:
height of installation class A up to 8 m, class B up to 6 m

Technical data:
● Current consumption from line < 150 µA
● Number of temperature class 8
● Max heigth of installation 8m
● Operating temperature range class A from -25C to +50C
● Operating temperature range class B from -25C to +65C

Temperature classes: A1, A2, B, A2S, BS, A1R, A2R, BR

* For use ONLY with POLON 4100 and POLON 4200 control panel
Two-sensor detector optical + flame DPR-4046
Main application:
• not used wooden objects
Limitations: dusty areas

Technical data:
● Current consumption from line < 150 µA
● Modes of operation 3*
● Operating temperature range from -25C to +55C

*possibility of separate testing of smoke and flame sensors

NOTE! The DPR-4046 detector is a SMOKE not flame detector, for that reason it is not
suitable for detection of fires, where ONLY FLAME without visible smoke appears.
Multi-sensor smoke and heat detector DOT-4046
Main application:
• underground garages
• kitchens
Limitations: dusty areas, high rooms

Technical data:
● Current consumption from line < 150 µA
● Modes of operation 4
● Test fires TF2 – TF6 and TF8
● Max heigth of installation 8 or 12 m (depends on choosen mode of operation)
● Operating temperature range from -25C to +55C
Multi-sensor smoke and heat detector DUT-6046

Technical data:
 Max curent consumption < 150 µA
 Max detection area 78 m2 or 176 m21)
 Operation modes: 6
 Test fires TF1 – TF9
 Operation temp. From -25C to +50C

Note: Instalation height – up to 8 m (except mode No 2, 5, 6)


1) Mode 2
Multi-sensor smoke and heat detector DUT-6046

Heat A1R
Optical IR

Optical UV
Mode 1
Multi-sensor smoke and heat detector DUT-6046

Heat A1R
Optical IR

Optical UV
Mode 2
Multi-sensor smoke and heat detector DUT-6046

Heat A1R
Optical IR

Optical UV
Mode 3
Multi-sensor smoke and heat detector DUT-6046

Optical IR

Heat A1R

or

or
Optical UV

Mode 4
Multi-sensor smoke and heat detector DUT-6046

Optical IR

Heat A1R

Optical UV

Mode 5
Multi-sensor smoke and heat detector DUT-6046

Optical IR

Heat A1R

Optical UV

Mode 6
Multi-sensor smoke and heat detector DUT-6046

Doubled smoke and heat sensors applied enable to:


● detection of any smoke particles,
● increased resistance to water vapours, dust or huge particles of aerosols,
● very high sensitivity and speed of reaction in case of fire,
● fulfills of the following test fires: TF1 (B), TF2 (B), TF3 (A), TF4 (A), TF5 (B),
TF6 (C), TF7 (A), TF8 (A), TF9 (A),
● increased resistance on dirteness,
● possible to be used in most buildings.
Multi-sensor smoke, heat and CO detector DTC-6046

Technical data:
 Max curent consumption < 150 µA
 Max detection area 78 m2 or 176 m2
 Operation modes: max 255
 Test fires TF1 – TF9
 Operation temp. From -25C to +50C
Multi-sensor smoke, heat and CO detector DTC-6046

Optical IR
Heat A1R

Optical UV
Carbon monoxide
Multi-sensor smoke, heat and CO detector DTC-6046

 Dual smoke and heat detection circuit


 CO detection circuit
 Wide range of test fires detection:
TF1, TF2, TF3, TF4, TF5, TF6, TF7, TF8, TF9
 4 smoke sensors sensitivity levels
 Up to 255 modes of operation
Radio detector set ZCR-4001
(DUR-4047 + ACR-4001)

Radio detector set enables for wireless


communication between wireless detectors with
control panels of POLON 4000 system

Application:
● historical objects, churches, museums
● arrangement of new rooms
● periodical protection of different objects/exhibitions
● other, where there is not possible to install wired
installation

Manual call poins – comming soon


ZCR-4001- smoke detector DUR-4007

Time of operation:
● 3 years in quiescent conditions
● if operates for a long time in fault
condition or in hard environmental
conditions or when there will be much
disturbances – the time of operation
can be shortened (up to 180 days)

Push button/contact signalling, that detector was removed from base.


Radio detector set ZCR-4001

Depending on placement of wireless detector and adapter, walls can


disturb radio signal and the range of communication can be decreased.
POLON 4000 – wireless operation
TZCR-4001 - wireless detectors testing kit

The wireless detectors testing kit is dedicated for checking, in the real
conditions, the level of radio signal between ACR-4001 adapter and
DUR-4047 wireless detector.
Detector’s base G-40

Base G-40 View of the detector from the bottom

● Easy connection between detectors and base


● Extremely easy installation
● No-screws connector for cables 0,5  2,5
● Safety blockade (to unlock, use a special key)
● Flexible fastening to surfaces
● Sealed inlet for installation wires
Key for unlocking
● Interoperates with base attachment PG-40 and masking
ring P-40
Accessories

Purpose: Purpose:
● isolation from the ceiling ● to mask a visible part of the base
● for installation of detectors on the
strings
● to lower the detector in high premises
Air duct enclosure OP-40 and protecting shield OZ-40
Anti-dust cover OK-40

Protection of detector during construction works


Addressable beam smoke detector DOP-6001
Main applications:
• theatres, cinemas, concert halls
• atria

Limitations:
• unstable structures,
• minimum distance 5 m

Technical data:
● Protected area up to 1500 m2
● Distance of operation with E39-R8 from 5 to 50 m
● Distance of operation with 4xE39-R8 from 50 to 100 m
● Max number of detectors
in addressable loop 64
● Programming from the control panel
● Operating temperature range from -25 C to +55 C
Manual call point ROP-4001M

Technical data:
● Current consumption
in quiescent conditions  140 μA
● Addressing from the control panel
● Wires diameter 0,8 – 1,2 mm2
● Case tightness
ROP-4001M IP 30
ROP-4001MH IP 55
● Operating temperature range
ROP-4001M from -25 C to +55 C
ROP-4001MH from -40 C to +70 C
In-Out addressable element EKS-4001
Purpose:
• Control of external fire protection units,
• Supervising of state of installation and state
execution of control signal

Technical data:
• Number of outputs 1
• Load capacity of relay 2 A/30 V, NO or NC
• Number of inputs 2
• Case tightness IP 65
• Operating temperature range from -25 C to +55 C

Available in single or multiple casings


In-Out addressable element EKS-4001W

Purpose:
• High voltage inputs and output
• Control and activation of fire protection
systems and devices
• Monitoring of sub-systems and
monitoring of the execution of control
command
• Reset mode

Technical data:
• Load capacity of relay 2 A or 230 V, 60 W
• Number of monitoring inputs 2, programmable (230 V or 24 V)
• Enclosure thigness IP 65
Multi-output control device EWS-4001
Purpose:
• Control of external fire protection units
• Control of voice alarm systems VAS

Technical data
• Number of relays 8
• Load capacity of relays 2 A/30 V, NO or NC
• Case tightness IP 65
• Operating temperature range from -25 C to +55 C
Multi-input supervising device EWK-4001
Purpose:
• Supervising of connected units

Technical data
• Number of inputs 8
• Initiation of input non-pot. contact NC or NO
• Case tightness IP 65
• Operating temperature range from -25 C to +55 C

EACH INPUT CAN BE INDEPENDENTLY ASCRIBED IN CONTROL PANEL


WITH IT’S OWN COMMUNIQUE
Addressable device ADC-4001M
ENABLES TO CONNECT AND ADDRESS OF
LINE ELEMENTS NOT OPERATING IN
POLON 4000 PROTOCOLE:
• conventional fire detectors i.e. of series 40
• beam smoke detectors DOP-40 or
intrinsically safe detectors
• intrinsically safe manual call points
• valves of sprinkler systems
• other

Technical data
• Number of inputs 1
• Modes of operation 6
• Max current available on side line 2 mA
• Max current consumption
from detection line 16 mA
• Case tightness IP 40
• Operating temperature range from -25 C to +55 C
Addressable signalling device SAL-4001

Characteristic features:
• 3 sounds variants
• 3 modes of power supply

Technical data:
• Level of acoustic signal (depending on power supply):
• From detector loop 85 dB
• From 9 V battery 94 dB
• From external power supplier 100 dB
• Operating temperature range from -10 C to +55 C

• The device is installed in G-40S base (as a set)


Sounders range SAW-6X0X
• 4 types:
• SAW-6101 conventional with tones,
• SAW-6106 conventional tone&voice,
• SAW-6001 addressable with tones,
• SAW-6006 addressable tone&voice,
• Programmable using dedicated application and
USB cable
• Up to 16 warning sequences at choice
• Synchronisation among one group
• 3 modes of power supply:
• detection line,
The siren is installed using
• 9 V battery,
G-40S base
• External power supplier,
Service GSM dialer TSG-1

Purpose:
 It allows you to send SMS messages about events
registered by the fire alarm control made by POLON-ALFA
 Can supervise operation of various devices equipped with
with potential-free output
 Uses GSM network, can work with standard size SIM card

Characteristic features:
 Possibility to program up to 5 different phone numbers to
send SMS’s to.
 Communication with the FAP using PMC-4000
 Connection to the panel via RS-232 or using relay outputs
 Connection with the computer using USB
 Frequency range: 850/900/1800/1900 MHz

NOTE: TSG-1 cannot be used for a fire alarm signals transsmision


PMC-4000/ModBus RTU convereter - CM-180-29

Purpose:
To convert the signal transmission protocol PMC-4000
embedded in all fire alarm control panels POLON 4000 to the
Modbus RTU protocol used in visualization systems

Technical data:
 Power supply 7 ÷ 35 [VDC]
 RS-232 max lenght 15 m
 RS-485 max lenght 1200 m
 Instalation DIN rail
Control Panel POLON 4100
Purpose:
The POLON 4100 control panel is dedicated
for fire protection of a small and middle-
sized objects.

Technical data:
• number of addressable lines/loops 2
• number of addressable line
elements (in one loop) 64
• max. number of detector zones 128
• relay outputs potential-free 3
• signalling line 1 (0,5 A/24 V)
• monitoring lines 2
• batteries 22 Ah
Control Panel POLON 4200
Purpose:
The POLON 4200 control panel is dedicated
for fire protection of a middle-sized
objects.

Technical data:
• number of addressable lines/loops 4
• number of addressable line
elements (in one loop) 64
• max. number of detector zones 256
• relay outputs potential-free 8
• signalling lines 1 (0,5 A/24 V)
1 (0,1 A/24 V)
• monitoring lines 2
• batteries 38 Ah
Control Panel POLON 4900
Purpose:
The POLON 4900 control panel is dedicated
for fire protection of a huge objects.
The control panel is equipped with doubled
(redundance) main processor.

Technical data:
• number of addressable lines/loops 4 or 8
• number of addressable line
elements (in one loop) 127
• network operation YES
• max. number of detector zones 1024
• relay outputs potential-free 16
• signalling lines 2 (0,5 A/24 V)
6 (0,1 A/24 V)
• monitoring lines 8
• batteries 90 Ah
Control Panel POLON 4500
Purpose:
The POLON 4500 control panel is dedicated
for fire protection of a huge objects,
including detection and automatic
extinguishing.

Technical data:
• number of addressable lines/loops 4
• number of addressable line
elements (in one loop) 127
• network operation YES
• max. number of detector zones 512
• relay outputs potential-free 8
• signalling lines 1 (1A/24V)
3 (0,5A/24V)
• monitoring lines 4
• batteries 38 – 180 Ah
Parallel indication terminal TSR 4000
Purpose:
The parallel indication terminal TSR 4000 is
dedicated for remote signalling of all
communicates of the control panel, to which it is
connected.

Characteristic features:
• interoperates with control panel of series
POLON 4000
• connection via serial interface RS 485 or
fibre optic
• possibility of connection up to 16 terminals
to one control panel
• equipped with internal reserve batteries

Technical data:
• relay output 1 A/30 V
• potential output 0,5 A/24 V
• LCD display 4 x 40
characters
POLON 4000 system – network operation
MASTER control panel

Up to 31 control panels
in network

• Serial interface RS 422


• Fiber optic transmission
Building Management System BMS

SECURITY SYSTEMS AUTOMATICS

fire detection and alarm system lights

intrusion alarm system power supply

access control system emergency power supply

CCTV communication system

voice evacuation system


Characteristic features of POLON 4000 system

1. Technical and quality benefits

• Up-to-date solutions, comparable to world leaders in fire protection,


• System dedicated for objects, required very high level of safety, including
„intelligent buildings”,
• Each system element use the microprocessor technique,
• Very functional, flexible system,
• Very wide range of various fire detectors (including unrivalled DOP-6001/6001R
beam smoke detector),
• Possibility to prepare detectors in every colour or making of special products for
operation in very hard environmental conditions,
• All fire detection and alarm system manufactured by one manufacturer…
Characteristic features of POLON 4000 system

2. Economic and exploitation benefits

• Software cost included to price of each control panel,


• Ease of operation, programming of FAS (simple, clear control panel’s software,
user interface),
• Programming and running of the system can be made by authorized installation
company – there is no need to call the manufacturer’s engineers,
• Service of system elements can be made by authorized, trained installers,
• POLON-ALFA guarantees it’s technical support in solving of many different
problems (engineering staff in marketing, service or design departments),
• Easy access to spare parts and possibility to repair even very old units (POLON-
ALFA guarantees about 10 years access to spare parts for units, which are no
longer manufactured)…
References – monumental objects

Zamoyscy Museum in Kozłówka

Cathedral in Bydgoszcz

Great Theatre in Warsaw


References – public objects

Warsaw School of Economics

University in Łódź

Silesian Voivodship Office in Katowice


References – industry

Refinery in Trzebinia

CCC Factory in Polkowice

Polpharma in Starogard Gdański


References - other

Tunnel in Katowice

Polish Television in Warsaw

Railway Station in Wrocław


Conventional fire alarm system IGNIS 1000
System IGNIS 1000

IGNIS 1080 IGNIS 1240 IGNIS 1520M


System IGNIS 1000

Fire extinguishing systems controller IGNIS 1520M (for one zone)


System IGNIS 2000

New IGNIS 2040


System IGNIS 2000

Main technical data:


• number of detection lines/zones: from 4 to 6
• signal lines: 2 (180 mA)
• detection line current: 1,6 mA
• programming: via USB interface
• internal memory: 1000 occurrences
• LCD display: with backlight
• end-of-line resistor: 5k6 kΩ
• signal line resistance: 10 kΩ
• programmable relays: 6
• alarm variants: 4
Optical smoke detector DUR-40

• test fire TF1 class B


• not recommended dusty areas
• height of installation max 11 m
Optical smoke detector DOR-40

• the most popular optical smoke detector


• not recommended dusty areas
• height of installation max 11 m
Fixed temperature, rate-of-rise heat detector TUP-40

• detects exceeding (fixed) or rise of temperature (rate-of-rise)


• maximum height of installation – up to 8 m (depending from class)
Two-sensor detector DOT-40

• test fires TF1 (B), TF2 (B), TF3 (B), TF4 (B), TF5 (B), TF6 (A)
• optical, smoke sensor + heat sensor
• modes of operation (3 possibilities using jumper built in) TUP and DOR;
• only TUP or DOR
• height of installation max 8 m / 11 m
Two-sensor heat detector TOP-40

• detects exceeding (fixed) or rise of temperature (rate-of-rise)


and flame in range 4,35 μm line of CO2
• case tightness IP 44
• height of installation 8m
Detector’s base G-40

Base G-40 View of detector from a side of base

Lock release key


Alarm indicator WZ-31

Used for indication of alarmed detectors,


installed in hidden spaces or closed rooms
Manual call points ROP-63 and ROP-63H

Case tightness:
• IP 30 (indoor)
• IP 55 (outdoor)
Beam smoke detectors DOP-6001, DOP-6001R
Beam smoke detectors DOP-6001, DOP-6001R

Principle of operation of beam smoke detectors


DOP-6001 and DOP-6001R
Addressable beam smoke detector DOP-6001

Main applications:
• theatres, cinemas, concert halls
• atria

Limitations:
• unstable structures,
• minimum distance 5 m

Technical data:
● Protected area up to 1500 m2
● Distance of operation with E39-R8 from 5 to 50 m
● Distance of operation with 4xE39-R8 from 50 to 100 m
● Max number of detectors
in addressable loop 64
● Proramming from the control panel
● Operating temperature range from -25 C to +55 C
Intrinsically safe detectors

PUO-35Ex DIO-37Ex

TUN-38Ex
DUR-40Ex
Control panels of IGNIS 1000 system can operate with detectors of intrinsically safe
version: ionization smoke detector DIO-37Ex, universal optical smoke detector DUR-
40Ex, UV flame detector PUO-35Ex, universal heat detector TUN-38Ex, installed behind
intrinsically safe separator.
Home smoke detectors ADR-20

ADR-20N
OPTICAL smoke detector designed for
detection of visible smoke, it can operate
as the independent detector or together
with another ones, connected in network
• power supply 9 V 6F22 battery

ADR-20R
OPTICAL smoke detector designed for
detection of visible smoke, it can be
installed on detection lines of any burglar
alarm control panel
• power supply 12 V DC ± 20%
• Relay output 1 A / 30 V
Certification

• EN 54 as the basic standards


• Certification body:
Science and Research Centre
for Fire Protection in Józefów

Accreditation Certificate for


Products Certification Body
AC 063

EU Notification No. 1438


Certification

• ATEX Certificates for


Ex products
• Certification body:
Central Mining Institute,
Experimental Mine „Barbara”

Accreditation Certificate for


Products Certification Body
AC 038
ISO 9001 Certificate
Thank you for your attention