You are on page 1of 7

CW10 and SEAKER

Applicable EMC standards

Thales Air Systems


Sensors overview

 VTIS systems is using 2 sensors :


 CW10 radar
 FURUNO radar : compliant with EMC naval standards
 Thales part : compliant with EMC EC standards

 SEAKER radar
 Compliant with EMC ground standards

 Naval standards are based on IEC 60 945


 EC standards are based on IEC 61 000

 Notes
 EC = European Community
 EC does not apply for naval applications

2 Thales Air Systems


IEC 61 000

 IEC 61 000 and EN 61 000 are the same (US or Europe)


 IEC 61 000 deals with EMC
 Emission and susceptibility standards
 Either in “light industrial environment” or “industrial environment”
 In “industrial”, equipment are more perturbating and so less sensitive
than “light industrial”
 In “light industrial”, equipment are less perturbating and so more
sensitive than “industrial”

Light industrial Industrial

Emission IEC-61000-6-3 IEC-61000-6-4

Susceptibility IEC-61000-6-1 IEC-61000-6-2

3 Thales Air Systems


IEC 61 000

 CISPR 22 lists the recommendations of the International


Electrotechnical Commission, in Geneva, Switzerland
 EN 55022 is the standard created from the CISPR 22
 The identification is made through the reference number :
CISPRxx-x, will become EN 550xx-x when adopted as a European
Standard.

 EN 55022 is called by EN 61000-6-3 as “conducted and


radiated perturbation” standard

4 Thales Air Systems


CW10 - FURUNO parts (FAR-2157)

Compliant with EN 60945 *


 EMC requirements based on IEC 60533 for group A
 IEC 60533 : Electrical and electronic installations in ships –
Electromagnetic compatibility
 Equipment group A : radio communication and navigation
equipment
 Applicable standards :
Conducted emission CISPR 16-2
Radiated emission CISPR 16-2
Conducted low frequency interference IEC 61000-4-16
Power supply variation IEC 61000-4-11
Power supply failure IEC 61000-4-11
Electrical fast transients IEC 61000-4-4
Surge voltage IEC 61000-4-5
Conducted radio frequency interference IEC 61000-4-6
Electrostatic discharge (ESD) IEC 61000-4-2
Electromagnetic field IEC 61000-4-3

* applicable standard for Marine Radar CE marking

5 Thales Air Systems


CW10 - THALES parts

Compliant with EN 61000-6-1 and EN 61000-6-3 *


 EN 61000-6-1 : Generic standards – Immunity for residential,
commercial and light-industrial environments
 Applicable standards :
EN 61000-4-2 Electrostatic discharge immunity test
EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
EN 61000-4-4 Electrical fast transient/burst immunity test
EN 61000-4-5 Surge immunity test
EN 61000-4-6 Immunity to conducted disturbances induced by radio-frequency fields test
EN 61000-4-8 Industrial frequency magnetic field immunity test
EN 61000-4-11 Voltage dips, short interruptions and voltage variation tests

 EN 61000-6-3 : Generic standards – Emission standard for


residential, commercial and light-industrial environments
 Applicable standards :
EN 55022/A1 Conducted Perturbations & Radiated Perturbations : class B
EN 61000-3-2 Limits of harmonics current emission
EN 61000-3-3 Limitation of voltage fluctuation and flicker in low voltage supply systems

* applicable standards for conformity to EMC Directive 2004/108/EC

6 Thales Air Systems


SEAKER

Compliant with EN 55022 and EN 61000-6-2 *


 EN 61000-6-2 : Generic standards – Immunity for industrial
environments
 Applicable standards :
 EN 61000-4-2
 EN 61000-4-3
 EN 61000-4-4
 EN 61000-4-5
 EN 61000-4-6
 EN 61000-4-11

 EN 55022 standard for conducted and radiated perturbation

* applicable standard for conformity to EMC Directive 2004/108/EC

7 Thales Air Systems