You are on page 1of 35

Training Session on Energy

Equipment

Compressors &
Electrical Equipment/

Compressed Air
Compressors

Systems
Presentation from the
“Energy Efficiency Guide for Industry in Asia”
www.energyefficiencyasia.org

1
© UNEP 2006
Training Agenda: Compressor

Introduction
Electrical Equipment/

Types of compressors
Compressors

Assessment of compressors and


compressed air systems
Energy efficiency opportunities

2
© UNEP 2006
Introduction

Significant Inefficiencies
• Compressors: 5 to > 50,000 hp
Electrical Equipment/

• 70 – 90% of compressed air is lost


Compressors

3
(McKane and Medaris, 2003)
© UNEP 2006
Introduction

Benefits of managed system


Electrical Equipment/

• Electricity savings: 20 – 50%


Compressors

• Maintenance reduced, downtime decreased,


production increased and product quality
improved

(eCompressedAir) 4
© UNEP 2006
Introduction

Main Components in Compressed


Electrical Equipment/

Air Systems
Compressors

• Intake air filters


• Inter-stage coolers
• After coolers
• Air dryers
• Moisture drain traps
• Receivers 5
© UNEP 2006
Training Agenda: Compressor

Introduction
Electrical Equipment/

Types of compressors
Compressors

Assessment of compressors and


compressed air systems
Energy efficiency opportunities

6
© UNEP 2006
Types of Compressors

Two Basic Compressor Types


Electrical Equipment/
Compressors

Type of
compressor

Positive
Dynamic
displacement

Reciprocating Rotary Centrifugal Axial

7
© UNEP 2006
Types of Compressors

Reciprocating Compressor
Electrical Equipment/

• Used for air and refrigerant compression


• Works like a bicycle pump: cylinder volume reduces
Compressors

while pressure increases, with pulsating output


• Many configurations available
• Single acting when using one side of the piston, and
double acting when using both sides

(King, Julie) 8
© UNEP 2006
Types of Compressors

Rotary Compressor
Electrical Equipment/

• Rotors instead of pistons: continuous


discharge
Compressors

• Benefits: low cost, compact, low weight,


easy to maintain
• Sizes between 30 – 200 hp
• Types
• Lobe compressor
• Screw compressor
Screw compressor
• Rotary vane / Slide vane 9
© UNEP 2006
Types of Compressors

Centrifugal Compressor
Electrical Equipment/

• Rotating impeller
Compressors

transfers energy
to move air
• Continuous duty

• Designed oil
free
• High volume
applications
> 12,000 cfm
10
(King, Julie)
© UNEP 2006
Types of Compressors

Comparison of Compressors
Electrical Equipment/

• Efficiency at full, partial and no load


Compressors

• Noise level
• Size
• Oil carry-over
• Vibration
• Maintenance
• Capacity
• Pressure 11
© UNEP 2006
Training Agenda: Compressor

Introduction
Electrical Equipment/

Types of compressors
Compressors

Assessment of compressors and


compressed air systems
Energy efficiency opportunities

12
© UNEP 2006
Assessment of Compressors

Capacity of a Compressor
Electrical Equipment/

• Capacity: full rated volume of flow of


Compressors

compressed gas
• Actual flow rate: free air delivery (FAD)
• FAD reduced by ageing, poor maintenance,
fouled heat exchanger and altitude
• Energy loss: percentage deviation of FAD
capacity

13
© UNEP 2006
Assessment of Compressors

Simple Capacity Assessment Method


Electrical Equipment/

• Isolate compressor and receiver and close receiver


outlet
Compressors

• Empty the receiver and the pipeline from water


• Start the compressor and activate the stopwatch
• Note time taken to attain the normal operational
pressure P2 (in the receiver) from initial pressure P1
• Calculate the capacity FAD:
P2 = Final pressure after filling (kg/cm2a)
P1 = Initial pressure (kg/cm2a) after bleeding)
P0 = Atmospheric pressure (kg/cm2a)
V = Storage volume in m3 which includes receiver,
after cooler and delivery piping
T = Time take to build up pressure to P2 in minutes
14
© UNEP 2006
Assessment of Compressors

Compressor Efficiency
Electrical Equipment/

• Most practical: specific power


Compressors

consumption (kW / volume flow rate)


• Other methods
• Isothermal
• Volumetric
• Adiabatic
• Mechanical 15
© UNEP 2006
Assessment of Compressors

Compressor Efficiency
Electrical Equipment/

Isothermal efficiency
Compressors

Isothermal efficiency =
Actual measured input power / Isothermal power

Isothermal power (kW) = P1 x Q1 x loger / 36.7

P1 = Absolute intake pressure kg / cm2


Q1 = Free air delivered m3 / hr
r = Pressure ratio P2/P1
16
© UNEP 2006
Assessment of Compressors

Compressor Efficiency
Electrical Equipment/

Volumetric efficiency
Compressors

Volumetric efficiency
= Free air delivered m3/min / Compressor displacement

Compressor displacement = Π x D2/4 x L x S x χ x n

D = Cylinder bore, meter


L = Cylinder stroke, meter
S = Compressor speed rpm
χ = 1 for single acting and 2 for double acting cylinders
17
n = No. of cylinders
© UNEP 2006
Assessment of Compressors

Leaks
Electrical Equipment/

• Consequences
Compressors

• Energy waste: 20 – 30% of output


• Drop in system pressure
• Shorter equipment life

• Common leakage areas


• Couplings, hoses, tubes, fittings
• Pressure regulators
• Open condensate traps, shut-off valves
• Pipe joints, disconnects, thread sealants 18
© UNEP 2006
Assessment of Compressors

Leak Quantification Method


Electrical Equipment/
Compressors

• Total leakage calculation:

Leakage (%) = [(T x 100) / (T + t)]

T = on-load time (minutes)


t = off-load time (minutes)

• Well maintained system: less than 10%


leakages
19
© UNEP 2006
Assessment of Compressors

Quantifying leaks on the shop floor


Electrical Equipment/

• Shut off compressed air operated equipments


Compressors

• Run compressor to charge the system to set


pressure of operation
• Note the time taken for “Load” and “Unload”
cycles
• Calculate quantity of leakage (previous slide)
• If Q is actual free air supplied during trial
(m3/min), then:

System leakage (m3/minute) = Q × T / (T + t) 20


© UNEP 2006
Assessment of Compressors

Example
Electrical Equipment/

• Compressor capacity (m3/minute) = 35


Compressors

• Cut in pressure, kg/cm2 = 6.8


• Cut out pressure, kg/cm2 = 7.5
• Load kW drawn = 188 kW
• Unload kW drawn = 54 kW
• Average ‘Load’ time =1.5 min
• Average ‘Unload’ time = 10.5 min

Leakage = [(1.5)/(1.5+10.5)] x 35 = 4.375 m3/minute


21
© UNEP 2006
Training Agenda: Compressor

Introduction
Electrical Equipment/

Types of compressors
Compressors

Assessment of compressors and


compressed air systems
Energy efficiency opportunities

22
© UNEP 2006
Energy Efficiency Opportunities

1. Location
Electrical Equipment/

• Significant influence on energy use


Compressors

2. Elevation
• Higher altitude = lower volumetric
efficiency

23
© UNEP 2006
Energy Efficiency Opportunities

3. Air Intake
Electrical Equipment/

• Keep intake air free from


Compressors

contaminants, dust or moist


• Keep intake air temperature low
Every 4 oC rise in inlet air
temperature = 1%
higher energy consumption

• Keep ambient temperature low when


an intake air filter is located at the 24
© UNEP 2006
Energy Efficiency Opportunities

4. Pressure Drops in Air Filter


Electrical Equipment/

• Install filter in cool location or draw


Compressors

air from cool location


• Keep pressure drop across intake air
filter to a minimum
Every 250 mm WC pressure drop = 2%
higher energy consumption

25
© UNEP 2006
Energy Efficiency Opportunities

5. Use Inter and After Coolers


Electrical Equipment/

• Inlet air temperature rises at each


Compressors

stage of multi-stage machine


• Inter coolers: heat exchangers that
remove heat between stages
• After coolers: reduce air temperature
after final stage
• Use water at lower temperature:
reduce power 26
© UNEP 2006
Energy Efficiency Opportunities

6. Pressure Settings
Electrical Equipment/

• Higher pressure
Compressors

• More power by compressors


• Lower volumetric efficiency
• Operating above operating pressures
• Waste of energy
• Excessive wear
27
© UNEP 2006
Energy Efficiency Opportunities

6. Pressure Settings
Electrical Equipment/

a. Reducing delivery pressure


Operating a compressor at 120 PSIG instead of 100
Compressors

PSIG: 10% less energy and reduced leakage rate

b. Compressor modulation by optimum


pressure settings
Applicable when different compressors connected

c. Segregating high/low pressure


requirements
28
Pressure reducing valves no longer needed © UNEP 2006
Energy Efficiency Opportunities

6. Pressure Settings
Electrical Equipment/

d. Design for minimum pressure drop in


the distribution line
Compressors

• Pressure drop: reduction in air pressure from


the compressor discharge to the point of use
• Pressure drop < 10%
• Pressure drops caused by
• corrosion
• inadequate sized piping, couplings hoses
• choked filter elements 29
© UNEP 2006
Energy Efficiency Opportunities

6. Pressure Settings
Electrical Equipment/

d. Design for minimum pressure drop in


Compressors

the distribution line

Typical pressure drop in compressed air line for


different pipe size (Confederation of Indian Industries) 30
© UNEP 2006
Energy Efficiency Opportunities

7. Minimizing Leakage
Electrical Equipment/

• Use ultrasonic acoustic detector


Compressors

• Tighten joints and connections


• Replace faulty equipment

8. Condensate Removal
• Condensate formed as after-cooler reduces
discharge air temperature
• Install condensate separator trap to remove
condensate 31
© UNEP 2006
Energy Efficiency Opportunities

9. Controlled usage
Electrical Equipment/

• Do not use for low-pressure


Compressors

applications: agitation, combustion air,


pneumatic conveying
• Use blowers instead

10. Compressor controls


• Automatically turns off compressor
when not needed
32
© UNEP 2006
Energy Efficiency Opportunities

9. Maintenance Practices
Electrical Equipment/

• Lubrication: Checked regularly


Compressors

• Air filters: Replaced regularly


• Condensate traps: Ensure drainage
• Air dryers: Inspect and replace filters

33
© UNEP 2006
Training Session on Energy
Equipment


Electrical Equipment/

Compressors &
Compressors

Compressed Air
Systems
THANK YOU FOR YOUR ATTENTION

34
© UNEP GERIAP
Disclaimer and References

• This PowerPoint training session was prepared as part of


the project “Greenhouse Gas Emission Reduction from
Electrical Equipment/

Industry in Asia and the Pacific” (GERIAP). While


reasonable efforts have been made to ensure that the
Compressors

contents of this publication are factually correct and


properly referenced, UNEP does not accept responsibility
for the accuracy or completeness of the contents, and shall
not be liable for any loss or damage that may be occasioned
directly or indirectly through the use of, or reliance on, the
contents of this publication. © UNEP, 2006.
• The GERIAP project was funded by the Swedish
International Development Cooperation Agency (Sida)
• Full references are included in the textbook chapter that is
35
available on www.energyefficiencyasia.org
© UNEP 2006