Wind Turbines: Challenges Associated with Corrosion Protection

Learning Outcomes
At the conclusion of this webinar you will be able to: Define the coating-specific sections Define challenges associated with corrosion protection of wind turbines Define wind turbine performance standards Define corrosion protection methods for wind turbines Define industry standards for corrosion protection of wind turbines Define coating systems used to protect wind turbines

Two Wind Markets Onshore and Offshore

Three Coatings Sections - Onshore


Rotor Blades

Nacelle

Tower

Five Coatings Sections Offshore


Rotor Blades Nacelle

Tower

Mooring Substructure

Challenges in Corrosion Protection of a Wind Turbine


Most wind farm owners/operators are looking for a 20-25 year service life on all coatings. In general, coating manufacturers and tower fabricators may be asked to provide a joint warranty for a specific time frame

Challenges in Corrosion Protection of a Wind Turbine Onshore


Wind turbines are usually placed in rural, often remote areas, making future maintenance challenging and expensive

Wind turbines can stretch hundreds of feet in the air, making accessibility difficult

Challenges in Corrosion Protection of a Wind Turbine Onshore


On-Shore Wind Turbines face the following challenges: Dew/condensation with or without salinity Exposure to UV light Wind blown debris Extreme temperature ranges 130 F (54 C) to -80F (62 C)

Challenges in Corrosion Protection of a Wind Turbine Offshore


In addition to the previous challenges, off-shore wind turbines face: Mechanical loads Floating Ice Biofouling in Submerged Zones Variation in Weather Conditions Wind and Waves

Rotor Blades Performance Standards


Coated rotor blades must be free of imperfections. Each surface imperfection on a wind turbine blade results in additional drag, and thus, decreases efficiency

Rotor Blades Performance Standards


Rotor blades flex when in use, therefore so must there protective coatings
Coatings must flex without fracturing Coating must be able to retain adhesion to the base coat and substrate when rotor blades flex

Rotor Blades Performance Standards


Coatings applied to Rotor Blades must be abrasion resistant. With Rotor Blades up to 5 MW (mega watts) being installed, they are susceptible to wind blown debris

Nacelle Performance Standards

The nacelle must be protected from corrosion using a protective coating system The inside must be kept clean and dry. Climate is controlled using dehumidifiers

Tower Section Standards


The tower consist of three sections:
Steel Tower which is protected with a coating Sub-Structure of the tower if sub-merged in water is protected by cathodic protection in conjunction with a coating system. If onshore just a coating system is necessary Mooring is protected with a coating

Tower System Requirements


ISO 12944 deals with performance requirements for protective paint systems
Defines test methods used to determine the composition of the separate components of the paint systems Defines laboratory performance test methods for assessing the paint systems Defines criteria for evaluating results

Tower System Requirements


Typical evaluation criteria is:
Degree of blistering and cracking (ASTM D 714 or ISO 4628) Degree of rusting (SSPC VIS 2, ASTM D 610 or ISO 4628) Degree of chalking (ISO 4628) Degree of flaking (ISO 4628) Adhesion (ASTM D 4541 or ISO 4624)

Tower System Requirements


Creep from scribe after 4200 hours of exposure to stresses of:
UV Light Condensation Salt Spray Freezing Immersion in Sea Water (ISO 2812)

Cathodic disbonding after 4200 hours per ISO 15711

Tower System Requirements


ISO 12944 defines five corrosion categories:
C1 (not corrosive interior atmosphere) up to C5-I and C5M (Industrial and Marine) Most wind farms are rural areas, C3 (Moderate Load) According to Part 5, C3 categories should be coated with a multi-coat system with a DFT of 6-10 mils

Tower System Requirements


ISO12944 Part 5 defines expected time of protection for various coating systems
Low Durability
(2 to 5 years)

Medium Durability
(5 to 15 years)

High Durability
(greater than 15 years)

On-Shore Typical Coating Systems


Three Coating System
Epoxy Zinc-Rich Primer (2 to 4 mils) Epoxy Intermediate Coat (4 to 6 mils) Polyurethane Topcoat (2 to 4 mils)

High Performance Two Coat Systems


Epoxy Zinc-Rich Primer (3 to 4 mils) Polyurethane Topcoat (4 to 5 mils)

Off-Shore Corrosion Protection


Standards for off-shore wind turbine protection are:
ISO 12944 NORSOK M 501

Off-Shore Corrosion Protection


ISO 12944 characterizes the conditions to which offshore wind turbines are exposed to as C5 M or IM 2 (immersion) C5 M categories are non-immersed and should be coated with a multi-coat system with DFTs in the range of 12 to 20 mils IM 2 indicates structure is immersed and should be coated with a multi-coat system with DFTs in the range of 20 to 40 mils in conjunction with cathodic protection

Off-Shore Corrosion Protection


NORSOK M-501 specifies similar systems Atmospheric exposure should have a minimum DFT of 13 mils Immersed exposure should have a minimum DFT of 18 mils

Typical Off-Shore Above Splashzone Coating Systems


Three Coating System
Epoxy Zinc-Rich Primer (2 to 4 mils) Epoxy Intermediate Coating (2 Coats at 4-6 mils) Polyurethane Topcoat (2-4 mils)

Typical Off-Shore Under Splashzone Coating Systems


Two Coat System Epoxy Coating (2 coats at 8-10 mils) NOTE- For areas under water (immersion service) NORSOK requires cathodic protection to be used in conjunction with coating system Install impressed cathodic corrosion protection Weld sacrificial anodes

Looking Ahead
Self repairing coatings
Healing agents/inhibitors release from microcapsules when coating gets damaged

Summary
Coating wind turbines can be challenging due to the complicated design of the structure and environmental location. To assure corrosion protection, industry standards must be followed and qualified coatings applied.