PUMPS
Pumps classification Positive displacement pumps Centrifugal pumps performance Pumps in operation
PUMPS CLASSIFICATION
diaphragm types. (Chemical lnj : TEG Circulation, ...) - Piston plunger may be single or double acting (Simplex, Duplex, Triplex).
- Rotating (Lube oil, Viscous fluids, ...)
PUMPS CLASSIFICATION
- Rotating depends on the close clearance between both rotating and stationary surfaces to seal the discharge from the suction.
- Diaphragm pumps
deliver a small, precisely controlled amount of liquid at a moderate to very high discharge pressure. Used as chemical injection pumps because of wide range of materials in which they can be fabricated, and their inherent leakproof design.
DIAPHRAGM PUMP
GEAR PUMPS
SCREW PUMPS
MULTISTAGE
10
MULTISTAGE
SHAFT
impellers
Casing
11
12
13
14
Volumetric pumps
15
Volumetric pumps
16
PUMPS
17
Centrifugal pumps
18
19
Nature (hydrocarbons, water,...), Corrosive elements presents in the liquid (H2S, salts...), Erosive elements presents in the liquid (solids and sludges) Pumping temperature, Density or relative density at pumping temperature, Vapour pressure at pumping temperature, Minimum and maximum operating gas pressure above liquid level in suction vessel, Maximum operating gas pressure above liquid level in discharge vessel.
20
Pumping characteristics
Normal flowrate (volume of fluid actually delivered per unit of time at the stated operating conditions indicated in the material balance established for the nominal operating conditions). Rated capacity or design flowrate (maximum flowrate required to take in account the variations of operating conditions to adapt the installation to the new field yields). Rated capacity is equal to the normal flowrate increased by the overcapacity factor or pump design factor. Maximum discharge pressure required at rated capacity. Minimum suction pressure available at rated capacity. Net Positive Suction Head Available (NPSHA) at rated capacity. Determined by No of pumps operated simultaneously.
21
Mechanical characteristics
Type of pump desired if there is a preference (for spare parts standardisation for instance) centrifugal, Triplex, etc..., horizontal, vertical in-line, etc... Flange ratings, flange type if other than standard, Mechanical seal required, Preferred metallurgy of major parts, Type of driver.
22
Mechanical characteristics
Type of driver.
- Most are electrical motors (usually fixed speed induction motor) - Nameplate rating
125% rated power if <22 KW 115% if >22 KW and <55 KW 110% if > 55KW
Material
- Usually cast-steel cases and cast iron internals (API 610)
Seals (API-682)
- Consists of stationary and rotating face - Requires cooling and lubrification
23
24
25
If the isometric flow is not available, the process engineer must establish a simplified flow diagram to show and estimate all characteristics indicated here above, in particular the suction and discharge line profile .
26
RATED CAPACITY It is equal to the normal flowrate corresponding to the nominal operating conditions increased by the overcapacity factor (or pump design factor). Overcapacity factor (or pump design factor) recommended :
10 % volume for feed pumps and pumps transferring fluids between column or drums, 20 % volume for reflux pumps and circulating pump around circuits, 20 % volume for boiler feed water pumps.
27
DIFFERENTIAL HEAD
Pressure Head difference : the difference in static pressure between the starting point and the finishing point of the system. Static Head difference : the difference in levels between the starting point of the system. Frictional Resistance : the head due to the resistance to flow as the liquid moves through the system.
28
Calculate system resistance (Conservatism : high static level and pressure differential, and the highest expected pipe friction). Calculate system resistance (best case : low of static level and pressure differential and the lowest pipe). Plot these curves as the extremes expected from the behaviour of the system. Select pumping equipment that successfully meets all reasonably expected operating conditions.
29
DIFFERENTIAL HEAD (Pr - Pa) Hmt = ---------------------- + (Zr - Za) + Hfa + Hfr
V@ P,T
30
DIFFERENTIAL HEAD
31
32
33
POWER
pw Q PdMax Psmin Lp
= brake pumping power, kW, = rated capacity or design liquid flowrate, m3/h, = maximum discharge pressure at centerline of pump discharge flange, (bar abs), = minimum suction pressure at the centerline of the pump suction flange, (bar abs), = pump efficiency
34
35
36
Formation and collapse of vapour cavities in a flowing liquid. Local pressure is reduced to that of the liquid vapour pressure at the temperature of the flowing liquid. At these locations, some of the liquid vaporises to form bubbles or cavities of vapour system. Collapse of bubbles begin when local pressure is higher than the vapour pressure. Result in Noise, severe pitting, and erosion of the impeller often results.
37
38
39
NPSH definition:
- Total inlet pressure, in meters or feet of liquid pumped determined at the pump suction connection (i.e. suction flange), minus the vapour pressure of the liquid pumped in meters or feet of liquid pumped at pumping temperature.
40
41
NPSH available
Po + -------- 2 -------Co - PVt NPRHA = -----V 2g V (Pa - PVt) NPRHA = ----------------------------- + Za - Hfa
V@ P,T
NPRHA = NPRHR + 1 m Where: Po = Dynamic press. at pump inlet Co = Fluid velocity at pump inlet P1 = Minimum pressure in pump Pa = Pressure in upstream vessel (bar) PVt = Vapor pressure of fluid @ T (bar) V = density G = gravity constant Za = Liquid level in upstream vessel (m) Hfa = Suction pressure losses (m) P, T = Pumping conditions
42
THE DIFFERENCE BETWEEN NPSH absolute AND NPSHR MEASURED USING AERATED WATER
43
44
45
46
47
AFFINITY LAWS
N2 Q 2 ! Q1 v N1
N2 H 2 ! H1v N1
N2 P 2 ! P1 v N1
2
D2 Q 2 ! Q1 v D1
D2 H 2 ! H 1v D1
2
New Head
New Power
D2 P 2 ! P1 v D1
48
MINIMUM FLOW
If discharge is shut-off, all energy converted to heat Liquid heats up rapidly and eventually vaporises Can result in catastrophic failures
- Pump vendor shall specify minimum flow requirements to ensure adequate flow
49
FLOW CONTROL
Throttling control
- By throttling valve in discharge piping. - Consumes energy since it artificially increases the system resistance to flow .
Speed control
- Not frequently done because most pumps are driven by fixed - speed motors. - Adjusting the rotational speed often consume substantially less energy. - Used for large, powerful pumps, because it allows to follow as closely as possible the area of highest pump efficiency. - An hydraulic coupling variable speed driver is used with a constant speed electric motor, - For large units gas and steam turbines are ideally suited as variable speed pump drivers.
Oil & Gas Processing Course
50
51
52
FLOW CONTROL
Recirculation control
- Used more frequently for positive displacement pumps - Caution for centrifugal pumps, because a wide-open bypass may result in a head so low that the pumped fluid will be circulated back to the suction at an extremely high rate, causing high power consumption, increase in fluid temperature, and possibly cavitation, as well as possible overloading the driver. - For many types of centrifugal pumps manufacturers stipulate minimum flow requirements to prevent pump damages. It is recommended to circulate the pumped fluid not back to the suction pump but back to the suction vessel
53
54
55
PARALLEL SERVICE
Pumps may be designed for parallel operation for any of the following typical reasons : Capacity increase for an existing pumping service. Due to the existing discharge system characteristic, the flow will not necessarily increase in proportion to the number of pumps added. Very high reliability is required without total reliance on the functioning of an autostart mechanism. Required capacity exceed capacity of any pump or driver model. Required capacity exceed the utility energy supply available for a single driver or driver type. Use of multiple pumps may allow investment savings, i.e. for high capacity services three 50 % sized pumps may require lower total investment than two 100 % sized pumps. To meet a requirement for flow capacity higher than normal on an infrequent basis, it may be preferable to have a service pump and its spare operate in parallel, rather than design each for the full over-normal flow rate. To increase plant safety and (or) reliability.
56
QR1 = Rated capacity of each half capcity s pump Qmax1 = Maximum capacity of single pump Qmax2 = Maximum operating flow obtained by two half capacity pumps in service
Oil & Gas Processing Course
57
SERIES SERVICE
When? Unusually high NPSHR, i.e. operating at a high differential head - design flow point requires a "booster" pump to pressure the suction of the high pressure pump. Head requirement exceeds the capability of a single pump and the flowrate is beyond the economic reciprocating pump range. The differential pressure requirement is low enough at times that one of several pumps in series can be turned off, as in transportation pipelines.
58
59
Multiphase Production
Before
When the development a marginal field or a group of remote wells is considered together with an existing central gathering system the traditional options for field development were: natural flow, artificial lift, In-field separation with crude oil pumps and gas compression systems
60
Multiphase pumps
The standardized Sulzer MPP pump range incorporates the latest 2nd generation helicoaxial Poseidon developed by IFP for the poseidon group (IFP, Total and Statoil) and subsequently licensed to Sulzer pumps.
The MPP pump is a multi-stage pump with each stage or compression cell comprising a rotating helico-axial flow impeller and a stationary diffuser.
The poseidon hydraulic design ensures that th epump can handle any void fractions without phase separation occcuring whilst also being very tolerant of sand particles.
61
Multiphase pumps
Advanced hydraulic design allied to simple modular concept Duplex metallurgy for corrosion resistance and H2S service Flow homogenizer for smoother mechanical running when sudden transient phenomena such as severe slugging are likely to occur Hydraulic flexibility and wide range of duties Easily retrofitted to take account of changing reservoir characteristics during the production life of the field
62
NAUTILUS PROJECT
Nautilus is a subsea 1.3 MW electrically driven multiphase booster station. The development of this project is being led by TOTAL with Sulzer having overall responsibility for thepump/motor unit. Nautilus has been designed for installation up to about 60 km (37 miles) from the receiving platform which is therefore expected to improve significantly the economic viability of subsea satellite or remote fields.
63
INSTALLATION FACILITIES
Temporary strainers Used for the protection during the initial operating period of new plants to collect weld beads, pipe scale, and any other foreign matter Permanent strainers Used where solids or foreign matter are a normal constituent of the pump fluid. cleaned when pressure drop reaches maximum allowable limit.
Oil & Gas Processing Course
64
INSTALLATION FACILITIES
65
INSTALLATION FACILITIES
66
67
OPERATION
68