Outline
Basic Terms Basic Concept Multiplexing Structure Network Topologies Network Management
GCS/BT
GCS/BT
Lowest Operating Digital Rate Analog Signal converted to 64 Kbps Data Stream 8 Bits = 1 Byte 8000 Bytes/Sec = 64000 bps From Analog to Digital 8000 samples per second 8000 * 8 = 64000 bps
GCS/BT 4
DS1 Signal
24 DS0 Multiplexed to 1 DS1 64 Kbps * 24 = 1536000 bps + 1 F bit * 8000 bps for Framing = 1,544,000 bps or 1.5 Mbps Commonly called a T1 Line (or C11 Container)
GCS/BT 5
E-1 Signal
GCS/BT
E-3 Signal
GCS/BT
E-4 Signal
4 E-3 Multiplexed to 1 E-4 34.363 Mbps * 4 + 1.812 = 139.264 Mbps Overhead Commonly called a E4 Line (or C4 Container)
GCS/BT
SDH Concept
GCS/BT
What is SDH ?
A Modular, Layered & Organized Architecture using Synchronous Multiplexing Technique. A Standardized hierarchical Set of Digital Transport Structures for transport of suitably Adapted Payloads A Set of Improved & Standardized Management Interfaces and Functions, allowing Digital Transmission Systems to inter-work in a multivendor environment.
GCS/BT 10
What is SDH ?
An Evolutionary Step in Transmission Technology, enabling Network Operators to compete more successfully in the face of deregulation
GCS/BT
11
Lower Order Path Layer Path Layer Network Higher Order Path Layer
Multiplex Section Layer Regenerator Section Layer Physical Medium GCS/BT Layer
12
Circuit Layers
64 Kbps layer Network ISDN Services Network Mgmt & Control links Leased Lines E1 / E2 / E3 / E4 Lines B-ISDN / Virtual Circuit layer Network Variable bit rate & integrated broadband Services
GCS/BT
13
Path Layers
VC-11 layer Network 64 Kbps links & 1.5 Mbps leased lines VC-12 layer Network 64 Kbps & 2 Mbps leased lines VC-3 layer Network LAN links, DS3 / E-3 leased lines VC-4 layer Network VC-12, VC-3, B-ISDN / Virtual path & HDTV links B-ISDN / Virtual path Network B-ISDN services, Virtual path link, Mgmt & GCS/BT Control links
14
GCS/BT
15
VC-11
VC-12
VC-2
VC-3
Lower Order Path Layer Path Layer Higher Order Path Layer
VC-3
VC-4
Section Layer
16
PATH
IP
SDH REG
SDH Multiplexer
SDH Multiplexer
PATH
MST
RST
MST
PDH ATM
PHOTONIC LAYER
PHOTONIC LAYER
PDH ATM IP
GCS/BT
18
(3)
[4] 2.48832 Gbps (2 ) [4]
(1)
622.08 Mbps
155.52 Mbps
STM-1
(Basic Signal)
GCS/BT
19
Voices 1890 1440 1920 7560 5760 7680 30240 23040 30720 120960 92160 122880
20
STM-4
622.08
STM-16
2488.32
STM-64
9953.28
TU-2
3 4 TU-12
VC-2
C-2
6312 kbit/s
2048 kbit/s
VC-12 C-12
TU-11
VC-11
C-11
1544 kbit/s
GCS/BT
21
GCS/BT
22
261 x N
STM-N Payload
GCS/BT
9 Rows
23
Synchronous Transport Module Level 1 9 Rows by 270 Columns 125 Micro Seconds Frame Length 8000 Frames per Second Bit Rate 9 * 270 * 8000 * 8 = 155520000 Bits per Second
GCS/BT
24
Transport Overhead 9 Columns * 9 Rows 9 Columns * 3 Rows = 27 bytes for RSOH 9 Columns * 1 Row = 9 bytes for AU pointer(s) 9 Columns * 5 Rows = 45 bytes for MSOH
Synchronous Payload Envelope (SPE) 2349 (9 * 261) bytes 150.336 Mbps Enough Capacity to carry a E-4 payload (139.264 Mbps)
GCS/BT
25
261
STM-1 Payload
GCS/BT
9 Rows
26
A1 B1 D1
A1
A1
A2 E1 D2
A2
A2
J0 F1 D3
X X
X X RSOH
9 Rows
F1
J0 K1, K2 S1 M1
Container
POH
Virtual Container
GCS/BT
29
End-To-End Path Connectivity Container Type Information Quality Monitoring Maintenance Automatic Protection Switching Tandem Connection Monitoring
GCS/BT
30
VC-3/4 POH
POH Bytes Functions Path Indication
J1 B3
C2 G1 F2 H4 F3 K3
N1
VC-11/12 POH
POH Bytes V5 J2 N2 K4 Functions Error Indication & Monitoring Path Indication Tandem Connection Monitoring Automatic Protection Switching (APS) Control
GCS/BT
32
POH
Virtual Container
AU-4 Pointer
Section Overhead (SOH)
VC-4
AU-4 PTR
Administrative Unit
AUG (= AU-4)
GCS/BT
SOH
STM-1
33
261
Regenerator Section Overhead (RSOH) AU Pointer Multiplex Section Overhead (MSOH) J1 B3 C2 G1 F2 H4 F3 K3 N1 STM-1 Payload H1 H1 H1 H2 H2 H2 H3 H3 H3
3 4
J1 B3 C2 G1 F2 H4 F3 K3 N1
J1 B3 C2 G1 F2 H4 F3 K3 N1
Fixed Stuff
Fixed Stuff
J1 B3 C2 G1 C-3 F2 34 Mbps H4 F3 K3 N1
84 34
GCS/BT
GCS/BT
35
Regenerator (REG): used to extend the fiber reach Terminal Multiplexer (TM): used in point-to-point network or at the end point of an Add/drop network Add/Drop Multiplexer (ADM): used in Ring or Linear Add/drop network Digital Cross-Connect (DXC or DCS): typically used in Mesh network to cross connect payload signals
GCS/BT
36
Point-to-Point Configuration
Linear Add/Drop (or Chain) Configuration
Ring Configuration
Star Configuration
Mesh Configuration
GCS/BT
37
Point-to-Point Configuration
User Site Central Office
SDH NE
STM-1 (OC-3)
SDH NE
A Simple Topology terminating SDH payload at each point of a Fiber Span Requires Single SDH Multiplexer (Terminal MUX) on a Single Route Typically, deployed in Transport Applications Enhanced Survivability with a Protection Path
GCS/BT 38
Central Office
STM-1 (OC-3) STM-1 (OC-3) SDH NE
SDH NE
SDH NE
Ring Configuration
Site B Working Path SDH NE Site A Site C SDH NE STM-1 Ring SDH NE
Closed Loop Configuration with Add/Drop Multiplexers Protection against: Fiber cut Signal failure/degrade (e.g., aging Laser) Node failure Common Ring Topologies UPSR (Unidirectional Path Switched Ring) BLSR (Bi-directional Line Switched Ring)
Protection Path
SDH NE Site D
UPSR
Vs
BLSR
Half High Speed Line Resources are Service & Half are Protection & assigned on a Span-by-Span basis Different Paths depending on fault location Single End-to-End Paths
All High Speed Line Resources are Service (Active/Standby) & Assigned on a round the Ring basis A Dedicated Standby Path for each Active Path Redundant End-to-End Paths
GCS/BT
2 Fiber UPSR
Site D
SDH NE
SDH NE
2 Fiber BLSR
Site D
SDH NE
SDH NE
GCS/BT
43
Site B Working Ring SDH NE Site A Site C SDH NE 2 Fiber DPR SDH NE
GCS/BT
44
Star Configuration
User Site 1
Point-to-Point Connectivity on different routes from a Centralized Site Terminating SDH Payload at each point of a Fiber Span
Central Office
) (OC-3 STM-1
SDH NE
STMM ST -1 (O
1 (OC
-3)
User Site 2
SDH NE
3) C-
User Site 2
SDH NE
GCS/BT
Mesh Configuration
Provides Capacity Sharing, Protection against Fiber Cut & Equipment Failures Efficient use of Bandwidth & Traffic Restoration Additional Protection using Spare Capacity
SDH NE SDH NE
SDH NE SDH NE
GCS/BT
46
GCS/BT
47
Configuration Management (CM) Fault Management (FM) Performance Management (PM) Security Management (SM)
DCN Management
GCS/BT
48
Equipment Configuration Termination Point (Physical Interfaces) Provisioning Cross-Connect (or Payload Map) Protection switching Synchronization Configuration (Timing Synchronization)
NE Recovery
GCS/BT
49
Fault Localization & Testing Fault Isolation Fault (or Alarm) Correlation Diagnostics (Loopbacks, Self-Diagnostics, etc.)
Alarm History Management
GCS/BT
50
PM Data Collection PM Attributes Setting Thresholds Setting PM Evaluation Criteria Start Time, etc. PM Data Reporting Performance Monitoring History 24-hour Registers 15-minute Registers Performance monitoring during Unavailable Time
GCS/BT 51
User Access Control to protect Network against Unauthorized Access Major Functions
GCS/BT
52
DCN Management
Configure & Control Resources in SDH NEs (e.g., DCC Management) Enable/Disable DCC (or ECC) Operational Status of DCC Network Parameters (Qos, Packet size, etc.) Management of Network Addresses Establish of Message Routing between DCC Nodes Network Route Configuration Routing Tables Route Priorities
GCS/BT 53