Professional Documents
Culture Documents
2G GSM
2G GSM Optimization
1. TEMS Set
Tablet with TEMS 2 Test Phones 2 SIM Cards TEMS for Postprocessing
(All Operators)
(AIS only)
B. GSM KPIs
TRUE MOVE/AIS MS1 Call Continuously MS2 Idle Spillage Test Handover Test Elevator Going up & Going down Test
DTAC MS1 Call Shortly (Normal) MS2 Call Shortly (Locked on IBC) Spillage Test Handover Test Elevator Going up & Going down Test
No IBC signal serving on streets and it should not be stronger than -85dBm.
Handover tests are success and smooth every entrances/exits. No drop call inside elevators and/or able to handover smoothly and signal should be stronger than -90dBm. Unless met these criteria, we should call OMC to request for adjusting parameters, adding neighbors and retuning frequencies. Customer is sometimes attend to ATP. Report for closing plan work after finished optimization.
3G HSPA
3G HSPA Optimization
TRUE MOVE
Tablet with Nemo Outdoor UE1: Test Phone + USIM UE2: HSPA Aircard +USIM UE3: Test Phone + USIM (Receiving Video Call) FTP Server (Provided by Operator) Nemo Analyze for Post-processing
Voice Call RSCP Voice Call Ec/No Video Call HSDPA HSUPA
B. HSPA KPIs
Round 1
Round 2
UE1: Video call continuously UE3: Receiving video call UE2: HSDPA FTP download continuously
Round 4: Handover
UE1: R99 Ping Web 100 times UE2: HSPA Ping Web 100 times
Round 5: Handover
Round 6: Parking HO
Round 7: Elevator
Round 8: Spillage
Check cell configuration (neighbors, parameters, etc.) Request for cell statistics to choose the suitable time for HSPA test (avoid to test during prime time) Request for plan work and make an appointment. Request OMC for adjusting parameters and/or adding neighbors. During walk test, signal under antenna should be strong (~ -45dBm up) depend on designing. Need to check DAS if found some weak signal. No IBC signal serving on streets and it should not be stronger than -85dBm. Handover tests are success and smooth every entrances/exits. No drop call inside elevators and/or able to handover smoothly and signal should be stronger than -90dBm. Unless met these criteria, we should call OMC to request for adjusting parameters and/or adding neighbors. Prepare report to submit. Need to correct if there are some comment. Arrange with customer to do ATP together. Correcting report as customers final comment. Report for closing plan work after finished optimization.
THANK YOU